P.A.A.F. Wouters

P.A.A.F. Wouters


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1993 in IEEE Transactions on Electrical Insulation
Verified
Journal Article
Open access
JWJ.M. Wetzer
J.M. Wetzer
PWP.A.A.F. Wouters
P.A.A.F. Wouters

7 March 2019 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
ADArmand van Deursen
Armand van Deursen
PWP.A.A.F. Wouters
P.A.A.F. Wouters
FSFred Steennis
Fred Steennis
The low-voltage distribution grid is an essential link for the integration of distributed renewable sources. It is expected to experience stronger loading and load variation in the near future. At the same time, part of the low-voltage network is an aging infrastructure. Distribution system operators are therefore becoming increasingly interested in being able to diagnose their low-voltage assets. This paper describes corrosion phenomena that are observed in aluminum conductors after a damage is inflicted to a cable section. Such a damage is suspected to initiate long-term degradation. Short-duration intermittent current peaks are observed in laboratory experiments and similar peaks are now also recorded in the field. The perspectives for online monitoring, by registering these events, are investigated by having a large number of measurement devices installed on connections in service. The research is directed to gain a better understanding of the relation between the current peaks and cable circuit failures as well as the underlying degradation mechanisms.

13 May 2004
Verified
Conference Paper
Closed access
PWP.C.J.M. van der Wielen
P.C.J.M. van der Wielen
PWP.A.A.F. Wouters
P.A.A.F. Wouters
JVJ. Veen
J. Veen
DAD.M. van Aartrijk
D.M. van Aartrijk
The development of an on-line PD detection system has its main challenges in the area of sensors and signal processing techniques. If localization is included by means of simultaneous signal detection at both cable ends, the problem arises of synchronizing the measuring systems at both sites accurately. One method, already successfully applied in off-line PD measurements, is the use of GPS. Besides its high costs, this system has one main disadvantage: it requires an external antenna in the line of sight of several satellites. This requirement may be a problem for on-line measurements because of the long measuring time. Another option to perform the synchronization is the injection of high-frequency pulses into one cable end and detecting them at the other end. Taking the propagation time along the cable length into account, this results in accurate synchronization of the measuring sides, without being dependent on any other system. This paper discusses several aspects of the pulse injection technique. The obtained resolution realized during field experiments with the method of pulse injection is within the resolution obtainable by means of GPS (100 ns).

28 February 2011 in European Transactions on Electrical Power
Verified
Journal Article
Closed access
PDF file
ASA. van Schijndel
A. van Schijndel
PWP.A.A.F. Wouters
P.A.A.F. Wouters
ESE.F. Steennis
E.F. Steennis
JWJ.M. Wetzer
J.M. Wetzer

1 July 1998 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
HCH. Casier
H. Casier
PWP.A.A.F. Wouters
P.A.A.F. Wouters
BGB. Graindourze
B. Graindourze
DSD. Sallaerts
D. Sallaerts
A single chip ISDN network terminator in an advanced 3.3 V, 0.5μ CMOS technology is presented. The circuit features a U-interface line driver with a THD better than -68 dB for an output swing of 5 V pp on a 67 Ω load. A novel quiescent current control circuit is implemented which reduces the variation of the quiescent current and facilitates the driver's compensation.

22 March 2022 in IEEE Access
Verified
Journal Article
Open access
ARAntonella Ragusa
Antonella Ragusa
PWP.A.A.F. Wouters
P.A.A.F. Wouters
HSHugh G. Sasse
Hugh G. Sasse
Alistair DuffyAlistair Duffy
Alistair Duffy
The performance of a new on-line partial discharge (PD) location method based on the Electromagnetic Time Reversal (EMTR) theory and the Transmission Line Matrix (TLM) method are investigated for characterization of Medium-Voltage (MV) networks. The distortion of the PD signal during its propagation along a cable connection including network components modelled based on experimental data is reproduced in simulation and the effectiveness of the EMTR-based method to localize the PD source is analyzed. In particular, the effects of the ring main units (RMUs), that behave as a complex impedance, the variation with frequency of the MV cable impedance and the reflection patterns, due to impedance mismatches, are considered and investigated. Simulation results are given showing the performance of the EMTR method in two different networks configurations: the former one with a RMU at the end of a MV cable and the latter one with a second MV cable connected to the RMU of the first configuration having a distribution transformer at its far end. The results show that the EMTR method is able, with only a single observation point, to localize PDs also in the presence of RMU with a relative error, with respect to the line length, of approximately 1%.