Natalie Hanrieder

Dr. Natalie Hanrieder


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2019 in Remote Sensing
Verified
Journal Article
Open access
PDF file
BNBijan Nouri
Bijan Nouri
Stefan WilbertStefan Wilbert
Stefan Wilbert
PKPascal Kuhn
Pascal Kuhn
NHNatalie Hanrieder
Natalie Hanrieder
MSMarion Schroedter-Homscheidt
Marion Schroedter-Homscheidt
RPRobert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
Robert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
The incoming downward shortwave solar irradiance is harvested to an increasing extent by solar power plants. However, the variable nature of this energy source poses an operational challenge for solar power plants and electrical grids. Intra hour solar irradiance nowcasts with a high temporal and spatial resolution could be used to tackle this challenge. All sky imager (ASI) based nowcasting systems fulfill the requirements in terms of temporal and spatial resolution. However, ASI nowcasts can only be used if the required accuracies for applications in solar power plants and electrical grids are fulfilled. Scalar error metrics, such as mean absolute deviation, root mean square deviation, and skill score are commonly used to estimate the accuracy of nowcasting systems. However, these overall error metrics represented by a single number per metric are neither suitable to determine the real time accuracy of a nowcasting system in the actual weather situation, nor suitable to describe any spatially resolved nowcast accuracy. The performance of ASI-based nowcasting systems is strongly related to the prevailing weather conditions. Depending on weather conditions, large discrepancies between the overall and current system uncertainties are conceivable. Furthermore, the nowcast accuracy varies strongly within the irradiance map as higher errors may occur at transient zones close to cloud shadow edges. In this paper, we present a novel approach for the spatially resolved real-time uncertainty specification of ASI-based nowcasting systems. The current irradiance conditions are classified in one of eight distinct temporal direct normal irradiance (DNI) variability classes. For each class and lead-time, an upper and lower uncertainty value is derived from historical data, which describes a coverage probability of 68.3%. This database of uncertainty values is based on deviations of the irradiance maps, compared to three reference pyrheliometers in Tabernas, Andalucia over two years (2016 and 2017). Increased uncertainties due to transient effects are considered by detecting transient zones close to cloud shadow edges within the DNI map. The width of the transient zones is estimated by the current average cloud height, cloud speed, lead-time, and Sun position. The final spatially resolved uncertainties are validated with three reference pyrheliometers, using a data set consisting of the entire year 2018. Furthermore, we developed a procedure based on the DNI temporal variability classes to estimate the expected average uncertainties of the nowcasting system at any geographical location. The novel method can also be applied for global tilted or horizontal irradiance and is assumed to improve the applicability of the ASI nowcasts.

6 June 2025 in Agriengineering
Verified
Journal Article
Open access
PDF file
AKAnna Kujawa
Anna Kujawa
JKJulian Kornas
Julian Kornas
NHNatalie Hanrieder
Natalie Hanrieder
SRSergio González Rodríguez
Sergio González Rodríguez
LHLyubomir Hristov
Lyubomir Hristov
RPRobert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
Robert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
Agrivoltaic greenhouses in southern Spain offer a sustainable way to manage excessive irradiance levels by generating renewable energy. This study presents a shading experiment on tomato cultivation in a raspa-y-amagado greenhouse in Almeria, southern Spain, during the 2023–2024 growing season. Photovoltaic modules were mimicked by opaque plastic sheets that were arranged in a checkerboard pattern on the roof of the greenhouse. Two shading zones (30% and 50% roof cover ratio) were compared against an unshaded control zone. Microclimate, plant physiology, yield and quality were monitored during the study. The results show that shading influenced the microclimate, which directly impacted crop yield. The 30% and 50% shading zones resulted in 15% and 26% crop yield reductions, respectively. A preliminary, theoretical analysis of potential revenues of the photovoltaic yield showed that reductions in crop yield can be overcompensated by the energy generated by the PV system. For the summer crop cycle, a higher PV production and lower crop yield reductions can be expected. The economic advantage demonstrates the potential of agrivoltaic greenhouses in southern Spain.

7 May 2019 in Remote Sensing
Verified
Journal Article
Open access
PDF file
NHNatalie Hanrieder
Natalie Hanrieder
AGAbdellatif Ghennioui
Abdellatif Ghennioui
Ahmed Alami MerrouniAhmed Alami Merrouni
Ahmed Alami Merrouni
Stefan WilbertStefan Wilbert
Stefan Wilbert
FWFlorian Wiesinger
Florian Wiesinger
ASAlexander Schade
Alexander Schade
In yield analysis and plant design of concentrated solar power (CSP) tower plants, increased uncertainties are caused by the mostly unknown solar attenuation between the concentrating heliostat field and the receiver on top of the tower. This attenuation is caused mainly by aerosol particles and water vapor. Various on-site measurement methods of atmospheric extinction in solar tower plants have been developed during recent years, but during resource assessment for distinct tower plant projects in-situ measurement data sets are typically not available. To overcome this lack of information, a transmittance model (TM) has been previously developed and enhanced by the authors to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity and barometric pressure measurements. Previously the model was only tested at one site. In this manuscript, the enhanced TM is validated for three sites (CIEMAT’s Plataforma Solar de Almería (PSA), Spain, Missour, Morocco (MIS) and Zagora, Morocco (ZAG)). As the strongest assumption in the TM is the vertical aerosol particle profile, three different approaches to describe the vertical profile are tested in the TM. One approach assumes a homogeneous aerosol profile up to 1 kilometer above ground, the second approach is based on LIVAS profiles obtained from Lidar measurements and the third approach uses boundary layer height (BLH) data of the European Centre for Medium-Range Weather Forecasts (ECMWF). The derived broadband transmittance for a slant range of 1 km ( T 1 k m ) time series is compared with a reference data set of on-site absorption- and broadband corrected T 1 k m derived from meteorological optical range (MOR) measurements for the temporal period between January 2015 and November 2017. The absolute mean bias error (MBE) for the TM’s T 1 k m using the three different aerosol profiles lies below 5% except for ZAG and one profile assumption. The MBE is close to 0 for PSA and MIS assuming a homogeneous extinction coefficient up to 1 km above ground. The root mean square error (RMSE) is around 5–6% for PSA and ZAG and around 7–8% for MIS. The TM performs better during summer months, during which more data points have been evaluated. This validation proves the applicability of the transmittance model for resource assessment at various sites. It enables the identification of a clear site with high T 1 k m with a high accuracy and provides an estimation of the T 1 k m for hazy sites. Thus it facilitates the decision if on-site extinction measurements are necessary. The model can be used to improve the accuracy of yield analysis of tower plants and allows the site adapted design.

20 July 2023 in Sensors
Verified
Journal Article
Open access
PDF file
GKGeorgios Kosmopoulos
Georgios Kosmopoulos
VSVasileios Salamalikis
Vasileios Salamalikis
Stefan WilbertStefan Wilbert
Stefan Wilbert
LZLuis F. Zarzalejo
Luis F. Zarzalejo
NHNatalie Hanrieder
Natalie Hanrieder
AKAndreas Kazantzidis
Andreas Kazantzidis
Low-cost sensors (LCSs) for particulate matter (PM) concentrations have attracted the interest of researchers, supplementing their efforts to quantify PM in higher spatiotemporal resolution. The precision of PM mass concentration measurements from PMS 5003 sensors has been widely documented, though limited information is available regarding their size selectivity and number concentration measurement accuracy. In this work, PMS 5003 sensors, along with a Federal Referral Methods (FRM) sampler (Grimm spectrometer), were deployed across three sites with different atmospheric profiles, an urban (Germanou) and a background (UPat) site in Patras (Greece), and a semi-arid site in Almería (Spain, PSA). The LCSs particle number concentration measurements were investigated for different size bins. Findings for particles with diameter between 0.3 and 10 μm suggest that particle size significantly affected the LCSs’ response. The LCSs could accurately detect number concentrations for particles smaller than 1 μm in the urban (R2 = 0.9) and background sites (R2 = 0.92), while a modest correlation was found with the reference instrument in the semi-arid area (R2 = 0.69). However, their performance was rather poor (R2 < 0.31) for coarser aerosol fractions at all sites. Moreover, during periods when coarse particles were dominant, i.e., dust events, PMS 5003 sensors were unable to report accurate number distributions (R2 values < 0.47) and systematically underestimated particle number concentrations. The results indicate that several questions arise concerning the sensors’ capabilities to estimate PM2.5 and PM10 concentrations, since their size distribution did not agree with the reference instruments.

7 March 2025 in Agronomy
Verified
Journal Article
Open access
PDF file
AKAnna Kujawa
Anna Kujawa
NHNatalie Hanrieder
Natalie Hanrieder
Stefan WilbertStefan Wilbert
Stefan Wilbert
ÁSÁlvaro Fernández Solas
Álvaro Fernández Solas
SRSergio González Rodríguez
Sergio González Rodríguez
RPRobert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
Robert Zentrum für Luft- und Raumfahrt e.V. Pitz-Paal
A key challenge in designing agrivoltaic systems is avoiding or minimizing the negative impact of photovoltaic-induced shading on crops. This study introduces a novel ray-tracing-based irradiance model for evaluating the irradiance distribution inside agrivoltaic greenhouses taking into account the transmission characteristics of the greenhouse’s cover material. Simulations are based on satellite-derived irradiance data and are performed with high spatial and temporal resolution. The model is tested by reproducing the agrivoltaic greenhouse experiment of a previous study and comparing the simulated irradiance to the experimentally measured data. The coordinates of the sensor positions in the presented application are optimized based on one day of raw data of minutely measured irradiance from the experimental study. These coordinates are then used to perform simulations over an extended timeframe of several months to take into account the seasonal changes throughout a crop cycle. The average deviation between the simulations and the experimental measurements in terms of radiation reduction is determined as 2.88 percentage points for the entire crop cycle.

9 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
NHNatalie Hanrieder
Natalie Hanrieder
AGAbdellatif Ghennioui
Abdellatif Ghennioui
Stefan WilbertStefan Wilbert
Stefan Wilbert
MSManajit SENGUPTA
Manajit SENGUPTA
LZLuis F. Zarzalejo
Luis F. Zarzalejo
Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.