The aim of this study was to compare the efficacy of the intraoperative bending of titanium mesh with the efficacy of pre-contoured “hybrid” patient-specific titanium mesh for the surgical repair of isolated orbital floor fractures. In-house 3D-printed anatomical models were used as bending guides. The main outcome measures were preoperative and postoperative orbital volume and surgery time. We performed a retrospective cohort study including 22 patients who had undergone surgery between May 2016 and November 2018. The first twelve patients underwent conventional reconstruction with intraoperative free-hand bending of an orbital floor mesh plate. The subsequent ten patients received pre-contoured plates based on 3D-printed orbital models that were produced by mirroring the non-fractured orbit of the patient using a medical imaging software. We compared the preoperative and postoperative absolute volume difference (unfractured orbit, fractured orbit), the fracture area, the fracture collapse, and the effective surgery time between the two groups. In comparison to the intraoperative bending of titanium mesh, the application of preformed plates based on a 3D-printed orbital model resulted in a non-significant absolute volume difference in the intervention group (p = 0.276) and statistically significant volume difference in the conventional group (p = 0.002). Further, there was a significant reduction of the surgery time (57.3 ± 23.4 min versus 99.8 ± 28.9 min, p = 0.001). The results of this study suggest that the use of 3D-printed orbital models leads to a more accurate reconstruction and a time reduction during surgery.
The present study aimed to analyze if a preformed “hybrid” patient-specific orbital mesh provides a more accurate reconstruction of the orbital floor and a better functional outcome than a standardized, intraoperatively adapted titanium implant. Thirty patients who had undergone surgical reconstruction for isolated, unilateral orbital floor fractures between May 2016 and November 2018 were included in this study. Of these patients, 13 were treated conventionally by intraoperative adjustment of a standardized titanium mesh based on assessing the fracture’s shape and extent. For the other 17 patients, an individual three-dimensional (3D) anatomical model of the orbit was fabricated with an in-house 3D-printer. This model was used as a template to create a so-called “hybrid” patient-specific titanium implant by preforming the titanium mesh before surgery. The functional and cosmetic outcome in terms of diplopia, enophthalmos, ocular motility, and sensory disturbance trended better when “hybrid” patient-specific titanium meshes were used but with statistically non-significant differences. The 3D-printed anatomical models mirroring the unaffected orbit did not delay the surgery’s timepoint. Nonetheless, it significantly reduced the surgery duration compared to the traditional method (58.9 (SD: 20.1) min versus 94.8 (SD: 33.0) min, p-value = 0.003). This study shows that using 3D-printed anatomical models as a supporting tool allows precise and less time-consuming orbital reconstructions with clinical benefits.
Gossypiboma (foreign body granuloma) in the tooth socket as a complication of tooth removal is rare. Several cases of gossypiboma have been reported after orthopedic, abdominal, otorhinolaryngology, or plastic surgery, but there has been only one reported case after oral surgery.
Individual cutting guides for the reconstruction of lower jaw defects with fibular grafts are often used. However, the application of these osteotomy tools is costly and time intensive. The aim of this study was to compare the precision of osteotomies using a 3D-printed guide with those using a universal, reusable, and more cost-efficient Multi-Use Cutting Jig (MUC-Jig). In this non-blinded experimental study, 10 cranio-maxillofacial surgeons performed four graft removals each in a randomized order using the same osteotomy angle, both proximally (sagittal cut) and distally (coronal cut), of a graft (45°, 30°, 15°, or 0°), first with the MUC-Jig then with the 3D-printed cutting guide. The 40 fibula transplants (Tx) of each method (n = 80) were then analyzed concerning their Tx length and osteotomy angles and compared to the original planning data. Furthermore, the surgeons’ subjective perception and the duration of the two procedures were analyzed. The mean relative length and mean relative angle deviation between the MUC-Jig (−0.08 ± 1.12 mm; −0.69° ± 3.15°) and the template (0.22 ± 0.90 mm; 0.36° ± 2.56°) group differed significantly (p = 0.002; p = < 0.001), but the absolute deviations did not (p = 0.206; p = 0.980). Consequently, clinically comparable osteotomy results can be achieved with both methods, but from an economic point of view the MUC-Jig is a more cost-efficient solution.
Background: The operation planning and production of individualized implants with the help of AI-based software after orbital fractures have become increasingly important in recent years. This retrospective study aimed to investigate the healthy orbitae of 372 patients from CT images in the bone and soft tissue windows using the Disior™ Bonelogic™ CMF Orbital software. (version 2.1.28). Methods: We analyzed the variables orbital volume, length, and area as a function of age and gender and compared bone and soft tissue windows. Results: For all variables, the intraclass correlation showed excellent agreement between the bone and soft tissue windows (p < 0.001). All variables showed higher values when calculated based on bone fenestration with, on average, 1 mL more volume, 0.35 mm more length, and 0.71 cm2 more area (p < 0.001). Across all age groups, men displayed higher values than women with, on average, 8.1 mL larger volume, a 4.78 mm longer orbit, and an 8.5 cm2 larger orbital area (p < 0.001). There was also a non-significant trend in all variables and both sexes toward growth with increasing age. Conclusions: These results mean that, due to the symmetry of the orbits in both the bone and soft tissue windows, the healthy orbit can be mirrored for surgical planning in the event of a fracture.