Simon Meyer

Dr. Simon Meyer


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
GSGuido Remigius Sigron
Guido Remigius Sigron
NRNathalie Rüedi
Nathalie Rüedi
FCFrédérique Chammartin
Frédérique Chammartin
SMSimon Meyer
Simon Meyer
BMBilal Msallem
Bilal Msallem
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
The aim of this study was to compare the efficacy of the intraoperative bending of titanium mesh with the efficacy of pre-contoured “hybrid” patient-specific titanium mesh for the surgical repair of isolated orbital floor fractures. In-house 3D-printed anatomical models were used as bending guides. The main outcome measures were preoperative and postoperative orbital volume and surgery time. We performed a retrospective cohort study including 22 patients who had undergone surgery between May 2016 and November 2018. The first twelve patients underwent conventional reconstruction with intraoperative free-hand bending of an orbital floor mesh plate. The subsequent ten patients received pre-contoured plates based on 3D-printed orbital models that were produced by mirroring the non-fractured orbit of the patient using a medical imaging software. We compared the preoperative and postoperative absolute volume difference (unfractured orbit, fractured orbit), the fracture area, the fracture collapse, and the effective surgery time between the two groups. In comparison to the intraoperative bending of titanium mesh, the application of preformed plates based on a 3D-printed orbital model resulted in a non-significant absolute volume difference in the intervention group (p = 0.276) and statistically significant volume difference in the conventional group (p = 0.002). Further, there was a significant reduction of the surgery time (57.3 ± 23.4 min versus 99.8 ± 28.9 min, p = 0.001). The results of this study suggest that the use of 3D-printed orbital models leads to a more accurate reconstruction and a time reduction during surgery.

20 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SMSimon Meyer
Simon Meyer
JHJan-Michael Michael Hirsch
Jan-Michael Michael Hirsch
CLChristoph S. Leiggener
Christoph S. Leiggener
BMBilal Msallem
Bilal Msallem
GSGuido Remigius Sigron
Guido Remigius Sigron
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Individual cutting guides for the reconstruction of lower jaw defects with fibular grafts are often used. However, the application of these osteotomy tools is costly and time intensive. The aim of this study was to compare the precision of osteotomies using a 3D-printed guide with those using a universal, reusable, and more cost-efficient Multi-Use Cutting Jig (MUC-Jig). In this non-blinded experimental study, 10 cranio-maxillofacial surgeons performed four graft removals each in a randomized order using the same osteotomy angle, both proximally (sagittal cut) and distally (coronal cut), of a graft (45°, 30°, 15°, or 0°), first with the MUC-Jig then with the 3D-printed cutting guide. The 40 fibula transplants (Tx) of each method (n = 80) were then analyzed concerning their Tx length and osteotomy angles and compared to the original planning data. Furthermore, the surgeons’ subjective perception and the duration of the two procedures were analyzed. The mean relative length and mean relative angle deviation between the MUC-Jig (−0.08 ± 1.12 mm; −0.69° ± 3.15°) and the template (0.22 ± 0.90 mm; 0.36° ± 2.56°) group differed significantly (p = 0.002; p = < 0.001), but the absolute deviations did not (p = 0.206; p = 0.980). Consequently, clinically comparable osteotomy results can be achieved with both methods, but from an economic point of view the MUC-Jig is a more cost-efficient solution.

7 March 2022 in Materials
Verified
Journal Article
Open access
PDF file
BMBilal Msallem
Bilal Msallem
MMMichaela Maintz
Michaela Maintz
FHFlorian S. Halbeisen
Florian S. Halbeisen
SMSimon Meyer
Simon Meyer
GSGuido Remigius Sigron
Guido Remigius Sigron
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
Cranioplasty with freehand-molded polymethylmethacrylate implants is based on decades of experience and is still frequently used in clinical practice. However, data confirming the fracture toughness and standard biomechanical tests are rare. This study aimed to determine the amount of force that could be applied to virtually planned, template-molded, patient-specific implants (n = 10) with an implant thickness of 3 mm, used in the treatment of a temporoparietal skull defect (91.87 cm2), until the implant cracks and finally breaks. Furthermore, the influence of the weight and porosity of the implant on its force resistance was investigated. The primary outcome showed that a high force was required to break the implant (mean and standard deviation 1484.6 ± 167.7 N), and this was very strongly correlated with implant weight (Pearson’s correlation coefficient 0.97; p < 0.001). Secondary outcomes were force application at the implant’s first, second, and third crack. Only a moderate correlation could be found between fracture force and the volume of porosities (Pearson’s correlation coefficient 0.59; p = 0.073). The present study demonstrates that an implant thickness of 3 mm for a temporoparietal skull defect can withstand sufficient force to protect the brain. Greater implant weight and, thus, higher material content increases thickness, resulting in more resistance. Porosities that occur during the described workflow do not seem to reduce resistance. Therefore, precise knowledge of the fracture force of polymethylmethacrylate cranial implants provides insight into brain injury prevention and serves as a reference for the virtual design process.

13 March 2024 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
BSBogomil Sabev
Bogomil Sabev
SASead Abazi
Sead Abazi
RPRaphael Patcas
Raphael Patcas
GHGabriel Hertig
Gabriel Hertig
SMSimon Meyer
Simon Meyer
PMPhilipp Metzler
Philipp Metzler

1 January 2020 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Verified
Journal Article
Closed access
SMSimon Meyer
Simon Meyer
JHJan-Michaél Hirsch
Jan-Michaél Hirsch
CLChristoph S. Leiggener
Christoph S. Leiggener
HZHans-Florian Zeilhofer
Hans-Florian Zeilhofer
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer

25 October 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
SASead Abazi
Sead Abazi
SCSophia Felicité Francisca Corten
Sophia Felicité Francisca Corten
MBMichel Beyer Michel Beyer
Michel Beyer Michel Beyer
NCNeha Umakant Chodankar
Neha Umakant Chodankar
BABurde Alexandru
Burde Alexandru
Florian Markus ThieringerFlorian Markus Thieringer
Florian Markus Thieringer
This preclinical investigation examined whether optical see-through augmented reality (AR) can transfer planned fronto-orbital cutting paths during simulated frontal debossing compared with patient-specific CAD/CAM cutting guides (CGs). Twenty printed skull replicas derived from one CT dataset were divided equally between workflows. Four superficial frontal or supraorbital grooves were created per skull and evaluated using postoperative CBCT and bidirectional closest-point distances. Overall deviation averaged the four trajectory means within each skull, giving 10 independent observations per group. Skull-level median [Q1, Q3] deviation was 0.543 [0.496, 0.588] mm with CGs and 1.098 [0.907, 1.333] mm with AR. Exact two-sided Mann–Whitney comparisons with Holm correction across overall accuracy, execution time, and four regions favored CGs for overall accuracy (adjusted p = 0.0208), superior frontal and right supraorbital accuracy, and execution time (adjusted p = 0.0029). The median [Q1, Q3] cumulative groove-execution time was 65.5 [61.5, 78.5] s with CGs and 152.0 [131.5, 208.8] s with AR. Mechanical guides deviated less with shorter groove-execution times in this standardized model, while operator and learning effects were not adjusted for. These findings concern surface trajectory reproduction in rigid models; clinical validation and assessment of the complete workflow are needed.