Ahmet Numan OZAKIN

Mr. Ahmet Numan OZAKIN


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2019 in Journal of Solar Energy Engineering
Verified
Journal Article
Closed access
PDF file
AOAhmet Numan OZAKIN
Ahmet Numan OZAKIN
KYKenan Yakut
Kenan Yakut
MMMansur Mustafaoglu
Mansur Mustafaoglu
In this study, the performance of the combined system of photovoltaic-heat pump (PV/T) and effects of a newly designed evaporator on the performance of the combined system were numerically investigated. The coefficient of performance (COP) value of the heat pump and electrical efficiency of the photovoltaic system were determined considering the studies carried out at the same resource temperature. ansys Fluent software was used in the numerical analysis. According to the results, the electrical efficiency increased as expected. The maximum electrical efficiency obtained for photovoltaic system was 2.5% higher than those without cooling systems and the COP of the heat pump system was determined to be 4.75 at its maximum. The maximum exergetic efficiency of the combined system was calculated to be 55.5% at 6 m/s of refrigerant velocity.


1 April 2016 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
AOAhmet Numan OZAKIN
Ahmet Numan OZAKIN
SKS. Karsli
S. Karsli
FKF. Kaya
F. Kaya
HGH. Güllüce
H. Güllüce
Although there are many fluctuations in energy prices, they seems like rising day by day. Thus energy recovery systems have increasingly trend. Photovoltaic systems converts solar radiation directly into electrical energy thanks to semiconductors. But due to the nature of semiconductors, whole of solar energy cannot turn into electrical energy and the remaining energy turns into waste heat. The aim of this research is evaluate this waste heat energy by air cooling system. So, the energy efficiency of the system will be increased using appropriate heat transfer technologies such as fin, turbulator etc.

5 July 2023 in Journal of Polytechnic
Verified
Journal Article
Closed access
PDF file
AKAbdüssamed Kabakuş
Abdüssamed Kabakuş
KYKenan Yakut
Kenan Yakut
AOAhmet Numan OZAKIN
Ahmet Numan OZAKIN
Endüstride birçok alanda kullanılmakta olan elektrosprey soğutma alanında son yıllarda keşfedilmeye başlanan bir konudur. Bu çalışmada literatürde hakkında oldukça kısıtlı çalışmalar bulunan elektrosprey soğutma ile mekanik sprey soğutmanın ısı alıcı üzerindeki soğutma performansı irdelenmiştir. Aynı şartlarda elektrosprey ile gerçekleşen ısı transferinin verileri deneyler yapılarak elde edilirken, mekanik sprey soğutma verileri Ansys Fluent CFD programı kullanılarak elde edilmiştir. Yapılan deneysel ve sayısal çalışmanın sonucunda daha küçük partikül çapı ve yüklü damlacıkların elde edildiği elektrosprey soğutmada mekanik sprey soğutmaya göre yaklaşık %15 daha iyi bir ısı transfer performansı gösterdiği belirlenmiştir. Elektrosprey metodunda, mekanik spreye göre 3,2 kW/m2 ısı akısında %13, 2,59 kW/m2 ısı akısında %14, 1,88 kW/m2 ısı akısında ise %17 daha iyi soğutma elde edildiği görülmüştür.

1 January 2025 in Heat Transfer Research
Verified
Journal Article
Open access
PDF file
AZAlperen Zengin
Alperen Zengin
FSFatih Sevim
Fatih Sevim
AOAhmet Numan OZAKIN
Ahmet Numan OZAKIN
FYFaruk Yeşildal
Faruk Yeşildal
MYMuhammet Kaan Yeşilyurt
Muhammet Kaan Yeşilyurt
This study addresses the efficiency decline in photovoltaic (PV) systems due to increased cell temperature. The aim is to find solutions to this fundamental problem in electricity generation from solar energy, which is a pressing concern in the field of renewable energy. The electrical efficiency of the PV system reaches its peak at a cell temperature of 25°C, at which it operates with a yield of around 13% under 1000 W/m2 irradiance. As the cell temperature increased from 25°C to around 34°C, there was a significant and constant decline in electrical efficiency. At steady-state conditions, the electrical efficiency of PV cells was observed to have decreased from approximately 13% to approximately 8% under 1000 W/m2, which corresponds to a decline around 38%. In order to cool down the PV panel to prevent this decline and to supply heat to the heat pump system, an industrial heat pump system that operates on a closed cycle using R-134a refrigerant was coupled with the PV system as having its evaporator in tight contact with the back of a 100-W PV panel to set up a photovoltaic thermal heat pump system (PV/T−HP). The PV/T−HP system performance was investigated for three levels of three system parameters (irradiance, condenser mass flow rate, and capillary tube length) through the utilization of the response surface method (RSM), seeking to identify the parameter that had the greatest impact on the heat pump's coefficient of performance (COP). The capillary tube length was found to have the greatest impact, yielding highest COP with 2-m tube length. A remarkable decline in electrical efficiency was observed when the cell temperature rose from 25°C to around 34°C, dropping from approximately 13% to about 8%. The highest COP of 2.61 and the highest efficiency of 0.12 were achieved at optimum conditions.

1 March 2020 in Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Verified
Journal Article
Closed access
PDF file
AOAhmet Numan OZAKIN
Ahmet Numan OZAKIN
FKFerhat Kaya
Ferhat Kaya
Panel yüzey sıcaklığı PV panelin performans parametreleri üzerinde çok önemli etkiye sahiptir. Özellikle yaz aylarında görülen panel yüzey sıcaklığındaki aşırı yükselme panel veriminde ciddi düşüşlere neden olur. Bu olumsuz durum panel yüzeyi soğutularak minimize edilebilir. Bu çalışmada, hava soğutmalı PVT sistemine kanatçıklar eklendi. Kontrol parametrelerinin (panelin arka yüzey sıcaklığı, fan hızı, kanal derinliği, kanatçık konfigürasyonu, kanatçık malzemesi) panel yüzey sıcaklığına, kanatçık sıcaklığına ve çıkış sıcaklığına etkisi Taguchi Yöntemi kullanılarak incelendi ve en uygun tasarım kombinasyonu belirlendi. Ayrıca ANSYS FLUENT analizi ile elde edilen görüntüler analiz edildi. Çalışmamızda monokristal panel kullanıldı. Bakır, alüminyum ve pirinç malzemelerden yapılmış kanatçıkların sık ve seyrek konfigürasyonları için deneyler yapıldı. Panel yüzey sıcaklığı, kanatçık sıcaklığı ve çıkış sıcaklığı için en etkili parametrelerin kanatçık konfigürasyonu, fan hızı ve kanal derinliği olduğu görüldü. Optimal tasarım kombinasyonu, panel yüzey sıcaklığı için A2-B3-C2-D3-E2 olduğu, kanatçık sıcaklığı için A1-B1-C3-D2-E2 olduğu, çıkış sıcaklığı için A1-B1-C3-D2-E3 olduğu bulundu.