For the great variety of light-emitting diodes (LEDs), there exists a wide range of LED radiation patterns. An approach for constructing patterns of higher accuracy is here considered. The latter is required when the design of optoelectronic systems or their optimization is carried out analytically. A weighting function is introduced that allows increasing the gradient of the diagram of different widths. It has been selected through mathematical analysis of the emission diagrams of different LEDs used in optoelectronic systems. Based on the least squares method an algorithm is created, and programs are developed in MATLAB environment to estimate the parameters of the approximation function. Its accuracy is evaluated by comparison with the approximation with Lambert source of order n. The results show higher accuracy of the proposed approximation function compared to those obtained by conventional methods. Recommendations on the application of the proposed approach are given.
The development of non-invasive optoelectronic technologies for human blood monitoring is one of the important research areas for medicine. A critical analysis of optoelectronic methods of blood research and the micromechanical systems based on them is carried out in this article. A design realization of a polarizing portable system for non-invasive monitoring of hematocrit as one of the basic homeostatic constants of the human body containing information about the microphysical parameters of blood cells has been substantiated. A physical model of polarized radiation conversion in a video information system of laser sensing of a biological research object has been formed. Visual and quantitative differences in the spatial distribution of polarization parameters of the scattered radiation for the states of the body with different hematocrit levels have been revealed. A scheme of a multichannel imaging portable system, based on a smartphone using miniature optical and microelectronic components of information conversion for non-invasive monitoring of microphysical blood parameters, has been created. The system implements the principle of polarimetric blood photometry and a multiparametric analysis of the polarization properties of the laser radiation scattered by blood. The developed portable optoelectronic system, based on a smartphone, can be used for rapid blood diagnostics in disaster medicine and the presence of clinical contraindications to the formation of invasive tests. The proposed polarization-based approach is a promising automated alternative to traditional devices and systems for the research of microphysical blood parameters.
Theoretical aspects of methods for calibrating Stokes polarimeters are considered. The prospects and opportunities for implementing the presented methods for calibrating portable polarization systems used in biology and medicine are determined. Based on a comparative analysis, a method for calibrating a portable Stokes polarimeter for medical applications is proposed. The chosen method provides the smallest error in measuring the parameters of the Stokes vector for calculating the parameters of optical anisotropy and researching the polarization properties of biological tissues. A series of experimental research and statistical analysis of the spatial distributions of the polarization parameters of the calibration sample was carried out to use the results for forming the instrument matrix of the developed Stokes polarimeter during calibration.
Omnidirectional optoelectronic systems (OOES) find applications in many areas where a wide viewing angle is crucial. The disadvantage of these systems is the large distortion of the images, which makes it difficult to make wide use of them. The purpose of this study is the development an algorithm for the precision calibration of an omnidirectional camera using a statistical approach. The calibration approach comprises three basic stages. The first stage is the formation of a cloud of points characterizing the view field of the virtual perspective camera. In the second stage, a calibration procedure that provides the projection function for the camera calibration is performed. The projection functions of traditional perspective lenses and omnidirectional wide-angle fisheye lenses with a viewing angle of no less than 180° are compared. The construction of the corrected image is performed in the third stage. The developed algorithm makes it possible to obtain an image for part of the field of view of an OOES by correcting the distortion from the original omnidirectional image.Using the developed algorithm, a non-mechanical pivoting camera based on an omnidirectional camera is implemented. The achieved mean squared error of the reproducing points from the original omnidirectional image onto the image with corrected distortion is less than the size of a very few pixels.
Subject of study. Polarization images corresponding to the 2D distributions of polarization state parameters for light scattered by biological specimens with different hematocrit levels were obtained by shining laser light in a given polarization state of blood-containing tissue through the nail bed of the left fifth finger. Aim of work. The aim of this work is to determine whether active video polarimetry is suitable for noninvasive real-time monitoring of blood hematocrit and to develop data-based criteria to identify hematocrit levels corresponding to various body states of human test subjects. Method. Physical models of changes in the parameters of polarized radiation during interaction with a biological specimen are used. A prototype optical design was developed for a Stokes video polarimeter capable of recording the irradiance distribution within a single analysis field on the sensitive area of a photodetector array. The digital images were processed using the Stokes–Mueller matrix formalism. A comparative statistical analysis of the 3D distributions for various parameters describing the polarization state (degree of polarization and the azimuth and ellipticity of the polarization ellipse) was performed to determine whether it is possible to detect differences in the hematocrit levels of human blood. Main results. A new approach to noninvasive hematocrit monitoring based on optical polarization is proposed. We obtained 3D distributions and histograms of light polarization state parameters for two human test subjects known to have different hematocrits. Statistical analysis revealed that significant differences in the second–fourth order statistical moments of the light polarization parameters are the most relevant diagnostic indicators for comparative analysis of biological tissues having different blood hematocrit levels. Practical significance. With further development, the proposed method can be applied to both medical diagnosis and emergency treatment. Timely detection of significant deviations from the normal hematocrit based on automated calculation and analysis of the data parameters identified will enable continuous hematocrit monitoring during surgical operations and effective real-time adjustment of blood viscosity.
Research Subject: The research subject was the error of optoelectronic video endoscopy systems in measuring the chord length of low-pressure cylinder steam turbine blades during shaft rotation. Objective: The objective was to reduce the error of the optoelectronic system in measuring the chord length of turbine rotor blades on a closed cylinder during shaft rotation. Methodology: Analytical research and computer modeling of the information transformation process during blade image formation and processing were carried out. Theoretical and experimental evaluations of the system error were conducted. Main Results: The structure of the components contributing to the error in estimating the chord length of low-pressure turbine blades was analyzed. The contribution of individual components to the total error was identified, and methods for reducing the most significant error components were proposed. Practical Significance: The effectiveness of the proposed methods for error reduction was validated through computer simulations and experimental studies on two system prototypes. The results showed that the standard deviation of the random error component in chord measurement during dynamic operation did not exceed 0.27 mm.