Fabian Michler

Mr. Fabian Michler

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Christoph WillChristoph Will
Christoph Will
KSKilin Shi
Kilin Shi
SSSven Schellenberger
Sven Schellenberger
TSTobias Steigleder
Tobias Steigleder
FMFabian Michler
Fabian Michler
AKAlexander Kölpin
Alexander Kölpin
This paper introduces heart sound detection by radar systems, which enables touch-free and continuous monitoring of heart sounds. The proposed measurement principle entails two enhancements in modern vital sign monitoring. First, common touch-based auscultation with a phonocardiograph can be simplified by using biomedical radar systems. Second, detecting heart sounds offers a further feasibility in radar-based heartbeat monitoring. To analyse the performance of the proposed measurement principle, 9930 seconds of eleven persons-under-tests’ vital signs were acquired and stored in a database using multiple, synchronised sensors: a continuous wave radar system, a phonocardiograph (PCG), an electrocardiograph (ECG), and a temperature-based respiration sensor. A hidden semi-Markov model is utilised to detect the heart sounds in the phonocardiograph and radar data and additionally, an advanced template matching (ATM) algorithm is used for state-of-the-art radar-based heartbeat detection. The feasibility of the proposed measurement principle is shown by a morphology analysis between the data acquired by radar and PCG for the dominant heart sounds S1 and S2: The correlation is 82.97 ± 11.15% for 5274 used occurrences of S1 and 80.72 ± 12.16% for 5277 used occurrences of S2. The performance of the proposed detection method is evaluated by comparing the F-scores for radar and PCG-based heart sound detection with ECG as reference: Achieving an F1 value of 92.22 ± 2.07%, the radar system approximates the score of 94.15 ± 1.61% for the PCG. The accuracy regarding the detection timing of heartbeat occurrences is analysed by means of the root-mean-square error: In comparison to the ATM algorithm (144.9 ms) and the PCG-based variant (59.4 ms), the proposed method has the lowest error value (44.2 ms). Based on these results, utilising the detected heart sounds considerably improves radar-based heartbeat monitoring, while the achieved performance is also competitive to phonocardiography.

8 September 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
SSSven Schellenberger
Sven Schellenberger
KSKilin Shi
Kilin Shi
TSTobias Steigleder
Tobias Steigleder
AMAnke Malessa
Anke Malessa
FMFabian Michler
Fabian Michler
AKAlexander Kölpin
Alexander Kölpin
Using Radar it is possible to measure vital signs through clothing or a mattress from the distance. This allows for a very comfortable way of continuous monitoring in hospitals or home environments. The dataset presented in this article consists of 24 h of synchronised data from a radar and a reference device. The implemented continuous wave radar system is based on the Six-Port technology and operates at 24 GHz in the ISM band. The reference device simultaneously measures electrocardiogram, impedance cardiogram and non-invasive continuous blood pressure. 30 healthy subjects were measured by physicians according to a predefined protocol. The radar was focused on the chest while the subjects were lying on a tilt table wired to the reference monitoring device. In this manner five scenarios were conducted, the majority of them aimed to trigger hemodynamics and the autonomic nervous system of the subjects. Using the database, algorithms for respiratory or cardiovascular analysis can be developed and a better understanding of the characteristics of the radar-recorded vital signs can be gained.

25 October 2017 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
Christoph WillChristoph Will
Christoph Will
KSKilin Shi
Kilin Shi
SSSven Schellenberger
Sven Schellenberger
TSTobias Steigleder
Tobias Steigleder
FMFabian Michler
Fabian Michler
AKAlexander Kölpin
Alexander Kölpin
Although a lot of research has been done into radar based heartbeat detection for the last years, it is still unknown which physiological effects truly underlie these measurement signals. This paper investigates the cardiovascular system as well as the effects due to the antenna characteristics and establishes a connection to the variety of heartbeat signals that can be found in comparable publications. For the first time, the cause of the diverging signal shapes is researched revealing the locally specific pulse wave curves named sphygmograms. Three different types are investigated: the carotid, the venous and the ventricle sphygmogram. Verification of the measured signal shapes is ensured by a laser sensor. Afterward, the influence of the filtering on the sphygmograms is researched as well as the influence of the antenna propagation on the radar signal. Finally, all novel insights are combined to substantiate the variety of published heartbeat signal curves.

31 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
FMFabian Michler
Fabian Michler
KSKilin Shi
Kilin Shi
SSSven Schellenberger
Sven Schellenberger
TSTobias Steigleder
Tobias Steigleder
AMAnke Malessa
Anke Malessa
AKAlexander Kölpin
Alexander Kölpin
Vital parameters are key indicators for the assessment of health. Conventional methods rely on direct contact with the patients’ skin and can hence cause discomfort and reduce autonomy. This article presents a bistatic 24 GHz radar system based on an interferometric six-port architecture and features a precision of 1 µm in distance measurements. Placed at a distance of 40 cm in front of the human chest, it detects vibrations containing respiratory movements, pulse waves and heart sounds. For the extraction of the respiration rate, time-domain approaches like autocorrelation, peaksearch and zero crossing rate are compared to the Fourier transform, while template matching and a hidden semi-Markov model are utilized for the detection of the heart rate from sphygmograms and heart sounds. A medical study with 30 healthy volunteers was conducted to collect 5.5 h of data, where impedance cardiogram and electrocardiogram were used as gold standard for synchronously recording respiration and heart rate, respectively. A low root mean square error for the breathing rate (0.828 BrPM) and a high overall F1 score for heartbeat detection (93.14%) could be achieved using the proposed radar system and signal processing.

13 January 2020 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
EHEmadeldeen Hassan
Emadeldeen Hassan
BSBenedict Scheiner
Benedict Scheiner
FMFabian Michler
Fabian Michler
MBMartin Berggren
Martin Berggren
EWEddie Wadbro
Eddie Wadbro
FLFabian Lurz
Fabian Lurz
This article utilizes a topology optimization approach to design planar multilayer transitions between substrate integrated waveguides (SIWs) and rectangular waveguides (RWGs). The optimization problem is formulated based on the modal field analyses and Maxwell's equations in the time domain solved by the finite-difference time-domain (FDTD) method. We present a time-domain boundary condition based on the Klein-Gordon equation to split traveling waves at homogeneous waveguide ports. We employ the boundary condition to compute portal quantities and to devise an adjoint-field system that enabled an efficient computation of the objective function gradient. We solve design problems that include more than 105,000 design variables by using less than 400 solutions of Maxwell's equations. Moreover, a new formulation that effectively combats the development of in-band resonances in the design is presented. The transition configuration allows the direct mount of conventional RWG sections on the circuit board and aims to cover the entire K-band. The guiding structure of the optimized transition requires blind vias, which is realized by a simple and cost-efficient technique. In addition, the transition is optimized for three different setups that can be used to provide different field polarizations. The proposed transitions show less than 1-dB insertion loss and around 15-dB return loss over the frequency interval 18-28 GHz. Several prototypes are fabricated with an excellent match between the simulation and measurement results.

5 June 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KSKilin Shi
Kilin Shi
SSSven Schellenberger
Sven Schellenberger
FMFabian Michler
Fabian Michler
TSTobias Steigleder
Tobias Steigleder
AMAnke Malessa
Anke Malessa
AKAlexander Kölpin
Alexander Kölpin
Objective: Radar technology promises to be a touchless and thereby burden-free method for continuous heart sound monitoring which can be used to detect cardiovascular diseases like heart murmurs and arrhythmia. However, the first and most crucial step is to differentiate between high- and low-quality segments in a recording in order to assess their suitability for a subsequent automated analysis. This paper gives a comprehensive study on this task and, for the first time, explicitly addresses the specific characteristics of radar-recorded heart sound signals. Methods: To gather heart sound signals recorded from radar, a bistatic radar system was built and installed at the university hospital. Under medical supervision, heart sound data were recorded from 30 test subjects. Different state-of-the-art pattern classification algorithms were evaluated for the task of automated signal quality index determination and the most promising one was optimized and evaluated on a separate holdout set. Results: The proposed classifier is able to achieve a maximum accuracy of up to 96.36% and demonstrates a superior classification performance compared to the state-of-the-art classifier with a maximum accuracy of 76.00 %. Conclusion: This paper introduces an ensemble classifier that is able to perform automated signal quality determination of radar-recorded heart sound signals with a high accuracy. Significance: Besides achieving a higher performance compared to state-of-the-art classifiers, the presented study is the first one to deal with the quality determination of heart sounds that are recorded by radar systems. The proposed method enables contactless and continuous heart sound monitoring for the detection of cardiovascular diseases.