Alexander Kölpin

Dr. Alexander Kölpin

Hamburg University of Technology
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2017 in IEEE Transactions on Communications
Verified
Journal Article
Closed access
EBElena Boshkovska
Elena Boshkovska
DNDerrick Wing Kwan Ng
Derrick Wing Kwan Ng
NZNikola Zlatanov
Nikola Zlatanov
AKAlexander Kölpin
Alexander Kölpin
RSRobert Schober
Robert Schober
In this paper, we consider a multiple-input multiple-output wireless powered communication network, where multiple users harvest energy from a dedicated power station in order to be able to transmit their information signals to an information receiving station. Employing a practical non-linear energy harvesting (EH) model, we propose a joint time allocation and power control scheme, which takes into account the uncertainty regarding the channel state information (CSI) and provides robustness against imperfect CSI knowledge. In particular, we formulate two non-convex optimization problems for different objectives, namely system sum throughput maximization and the maximization of the minimum individual throughput across all wireless powered users. To overcome the non-convexity, we apply several transformations along with a one-dimensional search to obtain an efficient resource allocation algorithm. Numerical results reveal that a significant performance gain can be achieved when the resource allocation is designed based on the adopted non-linear EH model instead of the conventional linear EH model. Besides, unlike a non-robust baseline scheme designed for perfect CSI, the proposed resource allocation schemes are shown to be robust against imperfect CSI knowledge.

26 July 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Christoph WillChristoph Will
Christoph Will
KSKilin Shi
Kilin Shi
SSSven Schellenberger
Sven Schellenberger
TSTobias Steigleder
Tobias Steigleder
FMFabian Michler
Fabian Michler
AKAlexander Kölpin
Alexander Kölpin
This paper introduces heart sound detection by radar systems, which enables touch-free and continuous monitoring of heart sounds. The proposed measurement principle entails two enhancements in modern vital sign monitoring. First, common touch-based auscultation with a phonocardiograph can be simplified by using biomedical radar systems. Second, detecting heart sounds offers a further feasibility in radar-based heartbeat monitoring. To analyse the performance of the proposed measurement principle, 9930 seconds of eleven persons-under-tests’ vital signs were acquired and stored in a database using multiple, synchronised sensors: a continuous wave radar system, a phonocardiograph (PCG), an electrocardiograph (ECG), and a temperature-based respiration sensor. A hidden semi-Markov model is utilised to detect the heart sounds in the phonocardiograph and radar data and additionally, an advanced template matching (ATM) algorithm is used for state-of-the-art radar-based heartbeat detection. The feasibility of the proposed measurement principle is shown by a morphology analysis between the data acquired by radar and PCG for the dominant heart sounds S1 and S2: The correlation is 82.97 ± 11.15% for 5274 used occurrences of S1 and 80.72 ± 12.16% for 5277 used occurrences of S2. The performance of the proposed detection method is evaluated by comparing the F-scores for radar and PCG-based heart sound detection with ECG as reference: Achieving an F1 value of 92.22 ± 2.07%, the radar system approximates the score of 94.15 ± 1.61% for the PCG. The accuracy regarding the detection timing of heartbeat occurrences is analysed by means of the root-mean-square error: In comparison to the ATM algorithm (144.9 ms) and the PCG-based variant (59.4 ms), the proposed method has the lowest error value (44.2 ms). Based on these results, utilising the detected heart sounds considerably improves radar-based heartbeat monitoring, while the achieved performance is also competitive to phonocardiography.

7 March 2013 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
GVGabor Vinci
Gabor Vinci
SLStefan Lindner
Stefan Lindner
FBFrancesco Barbon
Francesco Barbon
SMSebastian Mann
Sebastian Mann
MHMaximilian Hofmann
Maximilian Hofmann
AKAlexander Kölpin
Alexander Kölpin
A novel remote respiration and heartbeat monitoring sensor is presented. The device is a monostatic radar based on a six-port interferometer operating a continuous-wave signal at 24 GHz and a radiated power of less than 3 $\mu\hbox{W}$ . Minor mechanical movements of the patient's body caused by the respiration as well as hearbeat can be tracked by analyzing the phase modulation of the backscattered signal by means of microwave interferometry with the six-port network. High-distance measurement accuracy in the micrometer scale as well as low system complexity are the benefits of the six-port receiver. To verify the performance of the system, different body areas have been observed by the six-port radar. The proposed system has been tested and validated by measurement results.

8 September 2020 in Scientific Data
Verified
Journal Article
Open access
PDF file
SSSven Schellenberger
Sven Schellenberger
KSKilin Shi
Kilin Shi
TSTobias Steigleder
Tobias Steigleder
AMAnke Malessa
Anke Malessa
FMFabian Michler
Fabian Michler
AKAlexander Kölpin
Alexander Kölpin
Using Radar it is possible to measure vital signs through clothing or a mattress from the distance. This allows for a very comfortable way of continuous monitoring in hospitals or home environments. The dataset presented in this article consists of 24 h of synchronised data from a radar and a reference device. The implemented continuous wave radar system is based on the Six-Port technology and operates at 24 GHz in the ISM band. The reference device simultaneously measures electrocardiogram, impedance cardiogram and non-invasive continuous blood pressure. 30 healthy subjects were measured by physicians according to a predefined protocol. The radar was focused on the chest while the subjects were lying on a tilt table wired to the reference monitoring device. In this manner five scenarios were conducted, the majority of them aimed to trigger hemodynamics and the autonomic nervous system of the subjects. Using the database, algorithms for respiratory or cardiovascular analysis can be developed and a better understanding of the characteristics of the radar-recorded vital signs can be gained.

18 November 2010 in IEEE Microwave Magazine
Verified
Journal Article
Closed access
AKAlexander Kölpin
Alexander Kölpin
GVGabor Vinci
Gabor Vinci
BLBenjamin Laemmle
Benjamin Laemmle
DKDietmar Kissinger
Dietmar Kissinger
RWRobert Weigel
Robert Weigel
Modern wireless sensing and communication systems are often based on high bandwidth and high carrier frequencies. In the range beyond 100 GHz, common receiver architectures, like active homodyne or heterodyne receivers, have an issue with the amplification needed for mixing. Also, high bandwidth is a problem for these systems. In this context, the six-port receiver is a good alternative, just as well as for lowvolume markets. The six-port concept is based on the additive superposition of the two RF input signals using four different relative phases leading to constructive or destructive interaction. The resulting signals are directly downconverted to baseband by diode circuits operated in detector or mixing mode. The complexvalued information can be easily reconstructed from the four baseband voltages. Historic evolution leads from the reflectometer approach for an alternative vector network analyzer to receivers for sensing and communications. A recent topic is the technology gap in automotive workshops for adjusting the long-range radar sensor of a car. Here, the six-port concept as alignment tool is a good choice, because of its excellent phase resolution. Currently, the integration of the six-port receiver on a MMIC for frequencies beyond 100 GHz is the focus of current work and will be intensified in the future. Will the six-port concept replace common active homodyne and heterodyne receivers? No, but it is a serious alternative for millimeter-wave frequencies and ultrahigh-bandwidth applications in wireless sensing and communication systems. This modern concept can tap new markets for both wireless sensors and sensor networks.

7 January 2022 in Basic and Applied Ecology
Verified
Journal Article
Open access
JWJ.WOlfgang Wägele
J.WOlfgang Wägele
PBPaul Bodesheim
Paul Bodesheim
SBSarah J. Bourlat
Sarah J. Bourlat
JDJoachim Denzler
Joachim Denzler
MDMichael Diepenbroek
Michael Diepenbroek
SWStefan Wildermann
Stefan Wildermann