Performance characteristics of gas-phase microsensors will determine the ultimate utility of these devices for a wide range of chemical monitoring applications. Commonly employed chemiresistor elements are quite sensitive to selected analytes, and relatively new methods have increased the selectivity to specific compounds, even in the presence of interfering species. Here, we have focused on determining whether purposefully driven temperature modulation can produce faster sensor-response characteristics, which could enable measurements for a broader range of applications involving dynamic compositional analysis. We investigated the response speed of a single chemiresitive In2O3 microhotplate sensor to four analytes (methanol, ethanol, acetone, 2-butanone) by systematically varying the oscillating frequency (semicycle periods of 20–120 ms) of a bilevel temperature cycle applied to the sensing element. It was determined that the fastest response (≈ 9 s), as indicated by a 98% signal-change metric, occurred for a period of 30 ms and that responses under such modulation were dramatically faster than for isothermal operation of the same device (>300 s). Rapid modulation between 150 and 450 °C exerts kinetic control over transient processes, including adsorption, desorption, diffusion, and reaction phenomena, which are important for charge transfer occurring in transduction processes and the observed response times. We also demonstrate that the fastest operation is accompanied by excellent discrimination within a challenging 16-category recognition problem (consisting of the four analytes at four separate concentrations). This critical finding demonstrates that both speed and high discriminatory capabilities can be realized through temperature modulation.
A methylene-blue (MB)-labeled molecular beacon junction probe allows for a signal-on electrochemical detection of nucleic acids via target recycling using endonucleases. Electron transfer is reduced when the MB is intercalated in the stem of the molecular beacon, but then electron transfer from MB to a gold electrode is enhanced upon cleavage of the junction probe due to increased probability of MB approaching the electrode when attached to the more flexible ssDNA.
The present work demonstrates development of a miniaturized plasmonic platform comprised of a Au nanohole array (NHA) on a Si/Si3N4 substrate. Plasmonic responses of the NHA platform, which is coated with Cu-benzenetricarboxylate metal organic framework (MOF), are found to be promising even towards 500 nmol mol−1 (ppb) of acetone or ethanol vapors at room temperature. The sensing characteristics are further investigated by varying the operating temperature (296 K to 318 K) of the sensor and the concentrations of vapors (500 nmol mol−1 to 320 μmol mol−1). The plasmonic responses for the sensors are correlated with the adsorption of vapors on the MOF surface and modeled in accordance to Langmuir-type adsorption. Kinetic parameters are estimated for the adsorption of fixed concentrations of acetone and ethanol vapors within the studied operating temperature range. The linear variation of characteristic response time constants with the operating temperature provides Arrhenius activation energies for the adsorption of acetone and ethanol vapors. The comparatively lower activation energy estimated for the adsorption of ethanol results in faster and more sensitive response of the sensor towards that analyte. The plasmonic sensor for the detection of nmol mol−1 level acetone and ethanol vapors at room temperature along with the kinetic correlation on plasmonic response with the adsorption of the analytes described herein offer new insights to existing reports on surface modification and plasmonic detection.
Gas‐induced conductance changes were measured on palladium‐dosed single‐crystal tin oxide (SnO2) thin films having well‐characterized surface properties. Films were fabricated using two methods: reactive sputtering and chemical vapor deposition. Film orientation and crystal structure were determined by x‐ray diffraction, while surface morphology was characterized using atomic force microscopy. Conductance changes were measured continuously on film surfaces during alternating exposure and evacuation cycles to partial pressures of H2, O2, and CO in a vacuum chamber. The conductance change was found to be proportional to the square root of the initial film conductance and was interpreted in terms of gas‐induced changes in the width of a near‐surface space‐charge layer. The variation of conductance as a function of gas pressure during alternating exposure and evacuation cycles of H2 and O2 is consistent with a model that involves surface reactions between coadsorbates.
In this paper we describe a novel long-term microhotplate temperature sensor calibration technique suitable for Built-In Self Test (BIST). The microhotplate thermal resistance (thermal efficiency) and the thermal voltage from an integrated platinum-rhodium thermocouple were calibrated against a freshly calibrated four-wire polysilicon microhotplate-heater temperature sensor (heater) that is not stable over long periods of time when exposed to higher temperatures. To stress the microhotplate, its temperature was raised to around 400 °C and held there for days. The heater was then recalibrated as a temperature sensor, and microhotplate temperature measurements were made based on the fresh calibration of the heater, the first calibration of the heater, the microhotplate thermal resistance, and the thermocouple voltage. This procedure was repeated 10 times over a period of 80 days. The results show that the heater calibration drifted substantially during the period of the test while the microhotplate thermal resistance and the thermocouple-voltage remained stable to within about plus or minus 1 °C over the same period. Therefore, the combination of a microhotplate heater-temperature sensor and either the microhotplate thermal resistance or an integrated thin film platinum-rhodium thermocouple can be used to provide a stable, calibrated, microhotplate-temperature sensor, and the combination of the three sensor is suitable for implementing BIST functionality. Alternatively, if a stable microhotplate-heater temperature sensor is available, such as a properly annealed platinum heater-temperature sensor, then the thermal resistance of the microhotplate and the electrical resistance of the platinum heater will be sufficient to implement BIST. It is also shown that aluminum- and polysilicon-based temperature sensors, which are not stable enough for measuring high microhotplate temperatures (>220 °C) without impractically frequent recalibration, can be used to measure the silicon substrate temperature if never exposed to temperatures above about 220 °C.