Pieter Visser

Pieter Visser

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2011 in Journal of Geodesy
Verified
Journal Article
Closed access
PDF file
TGTh. Gruber
Th. Gruber
PVPieter Visser
Pieter Visser
CACh. Ackermann
Ch. Ackermann
MHM. Hosse
M. Hosse

25 February 2021 in Annales Geophysicae
Verified
Journal Article
Open access
PDF file
MPMinna Palmroth
Minna Palmroth
MGMaxime Grandin
Maxime Grandin
TSTheodoros Sarris
Theodoros Sarris
EDEelco Doornbos
Eelco Doornbos
STStelios Tourgaidis
Stelios Tourgaidis
MYMasatoshi Yamauchi
Masatoshi Yamauchi
The lower-thermosphere–ionosphere (LTI) system consists of the upper atmosphere and the lower part of the ionosphere and as such comprises a complex system coupled to both the atmosphere below and space above. The atmospheric part of the LTI is dominated by laws of continuum fluid dynamics and chemistry, while the ionosphere is a plasma system controlled by electromagnetic forces driven by the magnetosphere, the solar wind, as well as the wind dynamo. The LTI is hence a domain controlled by many different physical processes. However, systematic in situ measurements within this region are severely lacking, although the LTI is located only 80 to 200 km above the surface of our planet. This paper reviews the current state of the art in measuring the LTI, either in situ or by several different remote-sensing methods. We begin by outlining the open questions within the LTI requiring high-quality in situ measurements, before reviewing directly observable parameters and their most important derivatives. The motivation for this review has arisen from the recent retention of the Daedalus mission as one among three competing mission candidates within the European Space Agency (ESA) Earth Explorer 10 Programme. However, this paper intends to cover the LTI parameters such that it can be used as a background scientific reference for any mission targeting in situ observations of the LTI.

12 June 2023 in Journal of Space Weather and Space Climate
Verified
Journal Article
Open access
PDF file
CSChristian Siemes
Christian Siemes
CBClaudia Borries
Claudia Borries
SBSean Bruinsma
Sean Bruinsma
IFIsabel Fernandez-Gomez
Isabel Fernandez-Gomez
NHNatalia Hładczuk
Natalia Hładczuk
PVPieter Visser
Pieter Visser
We present new neutral mass density and crosswind observations for the CHAMP, GRACE, and GRACE-FO missions, filling the last gaps in our database of accelerometer-derived thermosphere observations. For consistency, we processed the data over the entire lifetime of these missions, noting that the results for GRACE in 2011–2017 and GRACE-FO are entirely new. All accelerometer data are newly calibrated. We modeled the temperature-induced bias variations for the GRACE accelerometer data to counter the detrimental effects of the accelerometer thermal control deactivation in April 2011. Further, we developed a new radiation pressure model, which uses ray tracing to account for shadowing and multiple reflections and calculates the satellite’s thermal emissions based on the illumination history. The advances in calibration and radiation pressure modeling are essential when the radiation pressure acceleration is significant compared to the aerodynamic one above 450 km altitude during low solar activity, where the GRACE and GRACE-FO satellites spent a considerable fraction of their mission lifetime. The mean of the new density observations changes only marginally, but their standard deviation shows a substantial reduction compared to thermosphere models, up to 15% for GRACE in 2009. The mean and standard deviation of the new GRACE-FO density observations are in good agreement with the GRACE observations. The GRACE and CHAMP crosswind observations agree well with the physics-based TIE-GCM winds, particularly the polar wind patterns. The mean observed crosswind is a few tens of m·s−1larger than the model one, which we attribute primarily to the crosswind errors being positive by the definition of the retrieval algorithm. The correlation between observed and model crosswind is about 60%, except for GRACE in 2004–2011 when the signal was too small to retrieve crosswinds reliably.

6 May 2022 in Acta Astronautica
Verified
Journal Article
Open access
LGLeonid I. Gurvits
Leonid I. Gurvits
ZPZsolt Paragi
Zsolt Paragi
RARicardo I. Amils
Ricardo I. Amils
IBIlse van Bemmel
Ilse van Bemmel
PBPaul Boven
Paul Boven
JZJ. Anton Zensus
J. Anton Zensus

22 June 2020 in Earth System Science Data
Verified
Journal Article
Open access
PDF file
JEJoao Encarnacao
Joao Encarnacao
PVPieter Visser
Pieter Visser
DADaniel Arnold
Daniel Arnold
ABAleš Bezděk
Aleš Bezděk
EDEelco Doornbos
Eelco Doornbos
CDChristoph Dahle
Christoph Dahle
Although the knowledge of the gravity of the Earth has improved considerably with CHAMP, GRACE, and GOCE (see appendices for a list of abbreviations) satellite missions, the geophysical community has identified the need for the continued monitoring of the time-variable component with the purpose of estimating the hydrological and glaciological yearly cycles and long-term trends. Currently, the GRACE-FO satellites are the sole dedicated provider of these data, while previously the GRACE mission fulfilled that role for 15 years. There is a data gap spanning from July 2017 to May 2018 between the end of the GRACE mission and start the of GRACE-FO, while the Swarm satellites have collected gravimetric data with their GPS receivers since December 2013. We present high-quality gravity field models (GFMs) from Swarm data that constitute an alternative and independent source of gravimetric data, which could help alleviate the consequences of the 10-month gap between GRACE and GRACE-FO, as well as the short gaps in the existing GRACE and GRACE-FO monthly time series. The geodetic community has realized that the combination of different gravity field solutions is superior to any individual model and set up the Combination Service of Time-variable Gravity Fields (COST-G) under the umbrella of the International Gravity Field Service (IGFS), part of the International Association of Geodesy (IAG). We exploit this fact and deliver the highest-quality monthly GFMs, resulting from the combination of four different gravity field estimation approaches. All solutions are unconstrained and estimated independently from month to month. We tested the added value of including kinematic baselines (KBs) in our estimation of GFMs and conclude that there is no significant improvement. The non-gravitational accelerations measured by the accelerometer on board Swarm C were also included in our processing to determine if this would improve the quality of the GFMs, but we observed that is only the case when the amplitude of the non-gravitational accelerations is higher than during the current quiet period in solar activity. Using GRACE data for comparison, we demonstrate that the geophysical signal in the Swarm GFMs is largely restricted to spherical harmonic degrees below 12. A 750 km smoothing radius is suitable to retrieve the temporal variations in Earth's gravity field over land areas since mid-2015 with roughly 4 cm equivalent water height (EWH) agreement with respect to GRACE. Over ocean areas, we illustrate that a more intense smoothing with 3000 km radius is necessary to resolve large-scale gravity variations, which agree with GRACE roughly at the level of 1 cm EWH, while at these spatial scales the GRACE observes variations with amplitudes between 0.3 and 1 cm EWH. The agreement with GRACE and GRACE-FO over nine selected large basins under analysis is 0.91 cm, 0.76 cm yr−1, and 0.79 in terms of temporal mean, trend, and correlation coefficient, respectively. The Swarm monthly models are distributed on a quarterly basis at ESA's Earth Swarm Data Access (at https://swarm-diss.eo.esa.int/, last access: 5 June 2020, follow Level2longterm and then EGF) and at the International Centre for Global Earth Models (http://icgem.gfz-potsdam.de/series/02_COST-G/Swarm, last access: 5 June 2020), as well as identified with the DOI https://doi.org/10.5880/ICGEM.2019.006 (Encarnacao et al., 2019).

14 September 2015 in Journal of Geodesy
Verified
Journal Article
Open access
PDF file
PVPieter Visser
Pieter Visser
JIJ. A. A. van Den Ijssel
J. A. A. van Den Ijssel
The European Space Agency Gravity field and steady-state Ocean Circular Explorer (GOCE) carries a gradiometer consisting of three pairs of accelerometers in an orthogonal triad. Precise GOCE science orbit solutions (PSO), which are based on satellite-to-satellite tracking observations by the Global Positioning System and which are claimed to be at the few cm precision level, can be used to calibrate and validate the observations taken by the accelerometers. This has been done for each individual accelerometer by a dynamic orbit fit of the time series of position co-ordinates from the PSOs, where the accelerometer observations represent the non-gravitational accelerations. Since the accelerometers do not coincide with the center of mass of the GOCE satellite, the observations have to be corrected for rotational and gravity gradient terms. This is not required when using the so-called common-mode accelerometer observations, provided the center of the gradiometer coincides with the GOCE center of mass. Dynamic orbit fits based on these common-mode accelerations therefore served as reference. It is shown that for all individual accelerometers, similar dynamic orbit fits can be obtained provided the above-mentioned corrections are made. In addition, accelerometer bias estimates are obtained that are consistent with offsets in the gravity gradients that are derived from the GOCE gradiometer observations.