This paper presents a reliable micro-grid for residential community with modified control techniques to achieve enhanced operation during grid connected, islanded and re-synchronization mode. The proposed micro-grid is a combination of solar photo-voltaic (PV), battery storage system and locally distributed DG systems with residential local loads. A modified power control technique is developed such that, local load reactive power demand, harmonic currents and load unbalance is compensated by respective residential local DG. However, active power demand of all local residential load is shared between the micro-grid and respective local DG. This control technique also achieves constant active power loading on the micro-grid by supporting additional active power local load demand of respective residential DG. Hence, proposed modified power control technique achieves transient free operation of the micro-grid during residential load disturbances. An additional modified control technique is also developed to achieve seamless transition of micro-grid between grid connected mode and islanded mode. The dynamic performance of this micro-grid during grid connected, islanded and re-synchronization mode under linear and non-linear load variations is verified using real time simulator (RTS).
14 September 2017 in IEEE Transactions on Industry Applications
A two-stage grid tied efficient solar photovoltaic (SPV) system with zero voltage switching (ZVS) and zero current switching (ZCS) at DC-DC converter stage and adaptive synchronization at inverter stage is proposed. In the first stage, an improved high step-up boost integrated flyback converter with quasi resonant voltage multiplier cell is proposed. ZVS turn-on of all MOSFETs and ZCS turn-off of all diodes of resonant voltage multiplier cell results in high efficient power conversion compared to the conventional boost integrated flyback converters. Small sized coupled inductor enhances magnetic utilization in this converter. Second stage consists of a single phase H-bridge grid interfaced inverter with variable band hysteresis current control technique. Amplitude adaptive notch filter (AANF) is used to extract fundamental unit voltage vector of grid voltage required for estimation of synchronized reference current for hysteresis controller. A 250W laboratory prototype is developed and experimentally evaluated. Experimental results demonstrate efficient renewable energy conversion at DC-DC converter stage and quality power injection at DC-AC inverter stage of the proposed grid tied SPV system under changing solar insulation levels.
7 February 2017 in IEEE Transactions on Industrial Informatics
This paper presents real-time implementation of a grid interfaced distributed generation (DG) system with modified current control loop using three phase amplitude adaptive notch filter (AANF) based synchronization tool. A grid current feedback based modified dq-current control technique for interfacing inverter is developed in order to achieve constant loading on the grid, transient-free operation, and power factor improvement close to unity power factor (UPF) of the utility grid during sudden load variations. This technique does not require separate calculation of reference reactive component and harmonics component of currents hence reduces control circuit complexity. In addition, it requires only three voltage and three current sensors. Three phase AANF is developed and is used for online extraction of utility voltage phase angle to generate synchronized reference current signals for interfacing inverter. AANF is used because of its adjustable accuracy and amplitude adaptability even under unbalanced voltage sag and swell, frequency variation, and distorted grid conditions. Fast and accurate behavior of three phase AANF improves the dynamic response of entire DG system control performance for sudden load variations. The dynamic behavior of the proposed grid interfaced DG system is experimentally evaluated in maintaining constant loading on grid, transient-free operation, and power factor improvement close to UPF operation of the utility grid, by compensating total reactive power and harmonic current demanded by variable linear as well as nonlinear load.
Grid integration of renewable energy through micro grid is latest in the research now for efficient and more reliable operation of distribution power system. Microgrid is required to operate in both grid connected mode and in islanded mode through proper diagnosis of the system conditions. Often transient conditions are handled by reserve capacities of distributed generation sources (DGs) and storage systems, which is dependent on the sharing of power by the varieties of connected DGs. The paper presents a Master-Slave method for load sharing without any communication link in between the DGs and the loads. Master DG is operated in indirect current control while in grid connected mode and is operated with PWM switching mode to present a voltage source in islanded mode. Slave DGs are always operated in indirect current control mode. Simulated results under MATLAB environment are present to validate the effectiveness of the control scheme.
This paper proposes a combined droop and master-slave control strategy for concurrent operation and control of standalone AC Microgrids operated in a distribution network. The combined droop and master-slave method developed for accurate load sharing among Voltage Source Inverters (VSI) improves voltage and frequency regulation in AC microgrid. The master VSI of microgrid is controlled through modified hierarchical droop controller which compensates voltage drop across feeder impedance and maintains load voltage at nominal value. The slave VSI is operated as a current source in microgrid and controlled in current control mode of VSI. In proposed control scheme, the local load demand in microgrid is compensated fully through slave VSI. This improves voltage and frequency regulation of microgrid as local load variations do not affect microgrid voltage and frequency. The dynamic performance of proposed control strategy for AC microgrid under varying load conditions is verified through real time simulator.
Reliable and eco-friendly power demand at consumer load end leads to integration of local distributed generation (DG) based micro-grids in the electricity network. Adequate local load sharing between the DG's in the micro-grids is necessary in islanded mode under faulty grid condition. This paper presents a grid connected micro-grid system with a back-to-back voltage source converter (VSC) based DG and single VSC's based DG's. The transition from grid connected to islanded mode under faulty grid condition is presented. A master-slave load sharing control method is developed for a micro-grid in islanded mode under faulty grid condition, in which a back-to-back VSC acts as a master DG and remaining as slave DG's. This control method regulates the DC-link voltage of master DG when its DC input power is unavailable in order to overcome the micro-grid shutdown. The transient performance of the proposed micro-grid in islanded mode under load variation, failure of slave DG and unavailability of DC input power to master DG is demonstrated. The overall performance of the proposed micro-grid under both grid connected and islanded mode is verified using MATLAB simulation and OPAL-RT real time simulator.