We summarized the effectiveness of home-based active video game interventions on physical and cognitive functions, as well as quality of life in adults with Parkinson’s disease. We also assessed th...
To explore the validity of the Actigraph and the influence of the placement of the sensor when estimating the active energy expenditure in four common daily activities (transfers, manual task, walking in overground and walking up and down stairs) in stroke survivors. Cross-sectional study. Department of Physical Medicine and Rehabilitation. A total of 46 subjects affected with stroke sequelae were wearing the Actigraph on three different locations—ankle, hip and wrist on the non-affected side—and performed four tasks: transfers, manual task, walking on flat ground and walking up and down stairs. The values of active energy expenditure estimated by the Actigraph were compared to those measured by a portable breathing gas exchange analyzer Metamax3B. The accuracy and agreement between Actigraph and Metamax values were analyzed with mean bias, root mean square error, correlation coefficient and Bland–Altman plots for each task and each sensor location. The mean bias between the Metamax and Actigraph placed on wrist, hip and ankle were, respectively, MD = 1.16 kcal (%MD = 3%), MD =−20.44 kcal (%MD =−58%) and MD = 17.64 kcal (%MD = 50%). The agreement with the Metamax was poor in general regardless of the sensor location and type of task (r = 0.12–0.58). This study found large differences and a poor agreement between the active energy expenditure as measured by the Actigraph and the Metamax according to the location of the sensor and the type of task performed by the subject.
Background: Health professionals need valid devices to assess a stroke individual’s ability to walk. The aim was to evaluate the validity of the estimation of the walked distance by wearable devices and the impact of the sensor’s position in stroke individuals. Methods: Post-stroke patients able to walk without human assistance were equipped with several wearable devices: pedometers, Actigraph, and Sensewear Armband placed according to the manufacturers' recommendations. Participants walked for 6 min at a comfortable speed wearing all sensors at the same time. We analyzed the validity of sensor-estimated distances according to their position using Bland–Altman analysis, root-mean-square error, and coefficient of correlation. Results: In total, 35 individuals were included (mean age = 65 ± 15 years). The best estimations were given by the Actigraph worn on the unaffected ankle (mean bias (MB) = 22.6 ± 32.4 m; p = 0.37) and by the pedometer worn on the unaffected hip (MB = 20.5 ± 24.6 m; p = 0.46). The other sensors and positions provided large estimation errors over 95 m (p < 0.05). Conclusion: This study led to a recommendation of a pedometer worn on the unaffected hip or an Actigraph worn on the unaffected ankle to get a valid estimation of the distance walked by stroke individuals.
5 November 2017 in Topics in Stroke Rehabilitation
(2018). Rating of perceived exertion with Borg scale in stroke over two common activities of the daily living. Topics in Stroke Rehabilitation: Vol. 25, No. 2, pp. 145-149.
1 September 2018 in Annals of Physical and Rehabilitation Medicine