Introducing a fluid microjet into the boundary layer to increase fluid momentum and hence delay separation is a method for actively controlling a flow separation region. The present work numerically analyzed the control of a separation bubble behind a ramp. For this purpose, we first verified the steady-state numerical results for a flow (without a jet) over the ramp against reliable experimental studies from the literature. Next, the effects of introducing a microjet to the flow were also verified. A jet was then placed at three different distances above the ramp to study its impact on various parameters, including velocities, Reynolds stresses, pressure, vorticity, streamlines, and the separation bubble size. As the jet was moved further back, the jet-induced upwash region grew considerably. Finally, the effects of using three identical jets were studied and compared against those of a single jet. The results indicated that using a three-jet array shrank the separation bubble. Using an array with d/D = 15 (distance between microjets over microjet diameter) can limit laterally the separation bubble about 2.75 times smaller than a single jet in the z-direction. Also, the employment of the jet managed to decrease the length of the separation zone in the x-direction up to 78%, in the case of Lx/L1 = 0.0143 (longitudinal distance of microjet from above the ramp over ramp length) and d/D = 10.
The present work studied various models for predicting turbulence in the problem of injecting a fluid microjet into the boundary layer of a turbulent flow. For this purpose, the one-equation Spalart–Allmaras (SA), two-equation k–ε and k–ω, multi-equation transition k-kL–ω, transition shear stress transport (SST), and Reynolds stress models were used for solving the steady microjet into the turbulent boundary layer, and their results are compared with experimental results. Comparing the results indicated that the steady solution methods performed sufficiently we for this problem. Furthermore, it was found that the four-equation transition SST model was the most accurate method for predicting turbulence in this problem. This model predicted the velocity along the x-axis in near- and far-jet locations with about 1% and 5% average errors, respectively. It also outperformed the other methods in predicting Reynolds stresses, especially at the center (nearly 5% error). Moreover, the modified four-equation transition SST model has improved the system's performance in predicting the studied parameters by utilizing Sørensen correlations in predicting Reθt (the transition momentum thickness Reynolds number), Flength (an empirical correlation that controls the length of the transition region), and Reθc (the critical Reynolds number where the intermittency first starts to increase in the boundary layer).
The flow separation control on an adverse-pressure-gradient ramp model is studied using various flow control strategies. Using a steady turbulent flow, the effects of utilizing an active hybrid control (suction and blowing) on the separation bubble behind a ramp are investigated numerically. A parametric analysis is conducted in which the actuators' pitch angle, diameter, and streamwise position are varied. The results are compared to determine the most effective method for compensating adverse pressure gradients and managing the separated flows on a ramp model. The best results for the blowing scenario correspond to a blowing actuator with a dimensionless distance of Lx/L1=−1/70 from the top of the ramp, a dimensionless diameter of d/L1=1/70, and a dimensionless angle of θ/θ0=2/6. The actuator is found to be able to wipe out the separation zone entirely at a velocity ratio of 3. The best results for the suction approach belong to a suction actuator with Lx/L1=1+1/70 from the top of the ramp, d/L1=3/70, and θ/θ0=−4/6. The modeling shows that the actuator removes the separation zone at a lower velocity ratio, namely, at 1.5. Nonetheless, a recirculation zone forms behind the suction point. Using a combined system, with a velocity ratio of 0.5 for a diameter of 3 and 2 for a diameter of 1, eliminates the separation zones on the ramp and after the suction actuator while lowering energy consumption. The blowing actuator consumed 3.2 times as much power as the combined actuator, whereas the suction actuator consumed 1.2 times as much power. Therefore, analyzing the present results as a prerequisite makes it possible to reduce flow separation and its adverse effects in more practical environments such as airfoils with an optimal cost.