The design philosophy of a strong‐column weak‐beam (SCWB), commonly used in seismic design codes for reinforced concrete (RC) moment‐resisting frame structures, permits plastic deformation in beams while keeping columns elastic. SCWB frames are designed according to beam‐to‐column flexural capacity ratio requirements in order to ensure the beam‐hinge mechanism during large earthquakes and without considering the influence of the beam‐to‐column stiffness ratio on the failure modes of global structures. The beam‐to‐column linear stiffness ratio is a comprehensive indicator of flexural stiffness, story height, and span. This study proposes limit values for different aseismic grades based on a governing equation deduced from the perspective of member ductility. The mathematical expression shows that the structural yielding mechanism strongly depends on parameters such as material strength, section size, reinforcement ratio, and axial compression ratio. The beam‐hinge mechanism can be achieved if the actual beam‐to‐column linear stiffness ratio is smaller than the recommended limit values. Two 1/3‐scale models of 3‐bay, 3‐story RC frames were constructed and tested under low reversed cyclic loading to verify the theoretical analysis and investigate the influence of the beam‐to‐column linear stiffness ratio on the structural failure patterns. A series of nonlinear dynamic analyses were conducted on the numerical models, both nonconforming and conforming to the beam‐to‐column linear stiffness ratio limit values. The test results indicated that seismic damage tends to occur at the columns in structures with larger beam‐to‐column linear stiffness ratios, which inhibits the energy dissipation. The dynamic analysis suggests that considering the beam‐to‐column linear stiffness ratio during the design of structures leads to a transition from a column‐hinge mechanism to a beam‐hinge mechanism.
1 January 2019 in Mathematical Problems in Engineering
The seismic performance of reinforced concrete members under earthquake excitation is different from that of whole structures; collapse mechanism may occur because of severe damage to individual members, even if the structural damage is not significant. Therefore, the potential seismic damage of each member should be investigated specifically apart from that of overall structure. In this study, a global damage model based on component classification is proposed to analyze the structural damage evolution rule and failure mechanism; then, the computed damage is compared with the experimental phenomena of three 1/3‐scale models of three‐storey, three‐bay reinforced concrete frame structures under low‐reversed cyclic loading. In addition, a probabilistic approach is finally adopted to quantify the seismic performance of RC frame structures based on the proposed global damage model. Results indicate that the structures with lower vertical axial force and beam‐to‐column linear stiffness ratio still maintain a certain load‐bearing capacity even when the interstorey drift angle exceeds the elastoplastic limit value and the cumulative damage of structures is mainly concentrated on the beam ends and column bottoms of the first floor at final collapse. Moreover, the structural failure probability at different performance levels would increase significantly if reinforced concrete frame structures suffer ground motions higher than the design fortification intensity, even up to eight times.
The sensor array with six sensors working at the frequency range of 429-436 MHz is designed and fabricated. The temperature sensitivity can be accurately controlled by the metallization thickness of the resonator on quartz substrate to keep the temperature-induced frequency shifts of each sensor within a limited bandwidth over a wide operating temperature ranging from -40°C to +150°C. The thermal parameters of sensor encapsulation are optimized according to the high voltage switchgear application. In order to meet the real-time requirement of sensor array measurement, discrete Hartley Transform (DHT) and the method of fast searching center frequency of sensors by comparison of I/Q and interrogation signals are used to reduce the query time, greatly improving the efficiency of polling of the sensor array. The measurement uncertainty of the practical SAW temperature sensor is less than 1°C, and the sensitivity of sensor is up to 4 KHz/°C.
10 October 2022 in Advances in Materials Science and Engineering
This study investigated the seismic performance of a 1/3 scale, three-story, and three-span RC frame subjected to static cyclic lateral loading. The failure process and mode were analyzed using the digital image correlation (DIC) method. Based on the test, finite element (FE) models were developed and verified. Using the proposed FE models, the parametric study was performed to investigate the influence of the opening rate, the position of infill walls, and the block strength on the seismic performance of the frame. Test results indicated that FE simulation results are correspondent to the testing results. The infilled wall increased the horizontal bearing capacity of the structure and the energy dissipation capacity. The opening masonry-infilled wall reduced the energy consumption capacity and the initial stiffness of the structure. Removing the infill walls on the first floor would change the failure mode of the frame. Improving the block strength could improve the bearing capacity of frames but has little effect on the energy dissipation capacity of the frame.