Weihong Bi

Dr. Weihong Bi


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XFXinghu Fu
Xinghu Fu
JZJiahao Zhou
Jiahao Zhou
ZFZizhen Fu
Zizhen Fu
MXMing Xu
Ming Xu
SHShuming Huang
Shuming Huang
WBWeihong Bi
Weihong Bi
A multi-parameter sensor based on dumbbell-shaped double-cladding fiber (DCF) structure cascaded long period fiber grating (LPFG) is proposed and fabricated. It is formed by discharging between single mode fiber (SMF) and DCF to form a waist-enlarged taper and then cascading two LPFGs. When the fiber is affected by the thermal expansion effect, thermo-optic effect and elasto-optic effect, the resonant peaks formed by inter-mode interference will shift, and the shifts generated by different resonant peaks are also different. By demodulating the wavelength shift of the three resonant peaks, the temperature, refractive index and axial strain can be measured by using the coefficient sensitivity matrix. The experimental results show that the temperature sensitivity of the three resonance peaks is 14.79pm/°C, 69.07pm/°C and 89.83pm/°C in the range of 25°C~80°C. The refractive index sensitivities of three resonance peaks are 14.27nm/RIU, -71.39nm/RIU and -141.07nm/RIU in the range of 1.3355~1.3715. The axial strain sensitivities of three resonance peaks are -2.26pm/με, -2.5pm/με and -3.14pm/με in the range of 75με~525με. The corresponding resolutions are 0.6905°C, 0.00054RIU and 36.323με, respectively. The sensor is simple and has good linearity. It can be widely used in environmental monitoring for different parameter.

1 March 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
SWSi-Yuan Wang
Si-Yuan Wang
WBWeihong Bi
Weihong Bi
WGWen-Yu Gan
Wen-Yu Gan
XLXin-Yu Li
Xin-Yu Li
BZBao-Jun Zhang
Bao-Jun Zhang
TJTian-Jiu Jiang
Tian-Jiu Jiang

28 January 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
XFXinghu Fu
Xinghu Fu
HXHaiyang Xie
Haiyang Xie
XZXianglong Zeng
Xianglong Zeng
GFGuangwei Fu
Guangwei Fu
WBWeihong Bi
Weihong Bi
A refractive index (RI) insensitive temperature sensor based on specialty triple-clad fiber (STCF) is proposed. Based on coupling mode theory, the STCF can be equivalent to a rod waveguide and two tube waveguides. Then the cladding mode resonance characteristic of STCF is analyzed by calculating different mode dispersion curves, which indicates that it works only on the mode resonance from core to the fluorine-doped silica cladding, and finally a resonance wavelength can be obtained. Two straightforward experiments are performed to prove its sensing properties. Experimental results show that it has sensitivities of 72.17 pm/°C at temperature range from 35°C~95°C with characteristics of insensitive to external RI in the range from 1.3450 to 1.4607. Thus, this proposed sensor can be used for solution temperature monitoring in real time.

14 September 2021 in IEEE Photonics Journal
Verified
Journal Article
Open access
XFXinghu Fu
Xinghu Fu
RRRan Ran
Ran Ran
QLQiannan Li
Qiannan Li
ZHZhexu Huang
Zhexu Huang
DLDongshu Li
Dongshu Li
WBWeihong Bi
Weihong Bi
A few mode fiber temperature sensor filled with PDMS based on vernier effect is proposed. It uses single mode fiber (SMF), few mode fiber (FMF), and polydimethylsiloxane (PDMS) to form the SMF-air microcavity-FMF-PDMS-FMF structure. It is to slot the glass capillary tube, place the two FMFs in the slot at a suitable distance, and fill the slot with PDMS multiple times and seal it. The PDMS is used as a sensing microcavity. We insert the SMF from the other end of the glass capillary tube, adjust the distance, fix the SMF and seal the connection. Two end faces of the SMF and the first FMF form an air reference microcavity. Since the refractive index of each medium is different, multiple reflective surfaces are formed to reflect. Because the second FMF is infinitely long, whose right end is beveled, it is considered that the sensor has four reflected beams. When the temperature changes, the length and refractive index of the PDMS microcavity will change, which will cause a change in the interference spectrum of the sensor. And because the vernier effect is formed by the superposition of the two microcavities, the temperature sensitivity can be amplified and the temperature can be measured with high sensitivity. The experimental results show that in the range of 40–56°C, the transmission spectrum of the sensor appears red shift with the increase of temperature, and the temperature sensitivity can reach 3.89nm/°C. The sensor is simple to manufacture, has high sensitivity, and has good application prospects.

1 August 2023 in IEEE Access
Verified
Journal Article
Open access
WBWeihong Bi
Weihong Bi
JYJin Yun
Jin Yun
LJLi Jiaxin
Li Jiaxin
SLSun Lingling
Sun Lingling
GFGuangwei Fu
Guangwei Fu
JWJin Wa
Jin Wa
In recent years, large numbers of jellyfish have congregated in marine areas, leading to a decline in other plankton and fisheries. Jellyfish themselves have a certain toxicity and aggression, which have a serious impact on the safety of human life. In order to detect the quantity and distribution of underwater jellyfish, and to be more proactive in the prevention and control of Aurelia outbreaks, this study proposed a method for in-situ detection of underwater jellyfish based on the improved Faster R-CNN network model. Firstly, the real data sets of three species of jellyfish in the Qinhuangdao sea area were established by using underwater high-definition camera. The Multi Scale Retinex with Colour Restoration (MSRCR) algorithm was used to improve the brightness and contrast of the underwater images. Secondly, the residual network Resnet50 was integrated into the backbone network for better feature extraction; then the semi-precision floating-point number FP16 was added to improve the training speed. Finally, comparative experiments were conducted to verify the improved network. The F1 value, the P-R curve, the Loss curve and the AP value of the three detection models were evaluated and compared. The experimental results showed that compared to Vgg16 network and YOLO V3 network, the training speed was improved from 1.85bit/s to 7.35bit/s, and the accuracy was also improved to over 0.98. The experimental results were good, and the research results provided a more accurate and faster method for the in-situ detection of underwater jellyfish.

5 April 2023 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
SWSi-Yuan Wang
Si-Yuan Wang
WBWeihong Bi
Weihong Bi
XLXin-Yu Li
Xin-Yu Li
BZBao-Jun Zhang
Bao-Jun Zhang
GFGuang-Wei Fu
Guang-Wei Fu
YZYong-Feng Zhang
Yong-Feng Zhang