Hongbo Zhou

Dr. Hongbo Zhou


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2015 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MYMiao Yu
Miao Yu
YHYoumin Hou
Youmin Hou
HZHongbo Zhou
Hongbo Zhou
SYShuhuai Yao
Shuhuai Yao
Preconcentration of biomolecules by electrokinetic trapping at the nano/microfluidic interface has been extensively studied due to its significant efficiency. Conventionally, sample preconcentration takes place in continuous flow and therefore suffers from diffusion and dispersion. Encapsulation of the preconcentrated sample into isolated droplets offers a superior way to preserve the sample concentration for further analysis. Nevertheless, the rationale for an optimal design to obviate the sample dilution prior to encapsulation is still lacking. Herein, we propose a pressure-assisted strategy for positioning the concentrated sample plug directly at the ejecting nozzle, which greatly eliminates the concentration decline during sample ejection. A distinctive mechanism for this plug localization was elucidated by two-dimensional numerical simulations. Based on the simulation results, we developed an on-demand nanofluidic concentrator in which the nanochannels were facilely generated through lithography-free nanocracking on a polystyrene substrate. By wisely implementing an on-demand droplet generation module, our system can adaptively encapsulate the highly concentrated sample and effectively enhance the long-term stability. We experimentally demonstrated the preconcentration of a fluorescently labelled biomolecule, bovine serum albumin (BSA), by using an amplification factor of 104. We showed that, by adjusting the applied voltage, accumulation time, and pulsed pressure imposed on the control microchannel, our system can generate a droplet of the desired volume with a target sample concentration at a prescribed time. This study not only provides insights into the previously unidentified role of assisted pressure in sample positioning, but also offers an avenue for varied requirements in low-abundance biomolecule detection and analysis.

15 February 2020 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
HPHuo Peng
Huo Peng
MZMinjie Zhu
Minjie Zhu
ZGZehang Gao
Zehang Gao
CLChengyue Liao
Chengyue Liao
CJChunping Jia
Chunping Jia
JZJianlong Zhao
Jianlong Zhao

29 October 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
AWAnyan Wang
Anyan Wang
ZWZhenhua Wu
Zhenhua Wu
HYH YH
H YH
HZHongbo Zhou
Hongbo Zhou
Lei WuLei Wu
Lei Wu
JZJianlong Zhao
Jianlong Zhao
Mycoplasma pneumonia (MP) is a common respiratory infection generally treated with macrolides, but resistance mutations against macrolides are often detected in mycoplasma pneumoniae in China. Rapid and accurate identification of mycoplasma pneumoniae and its mutant type is necessary for precise medication. This paper presents a 3D-printed microfluidic device to achieve this. By 3D printing, the stereoscopic structures such as microvalves, reservoirs, drainage tubes, and connectors were fabricated in one step. The device integrated commercial polymerase chain reaction (PCR) tubes as PCR chambers. The detection was a sample-to-answer procedure. First, the sample, a PCR mix, and mineral oil were respectively added to the reservoirs on the device. Next, the device automatically mixed the sample with the PCR mix and evenly dispensed the mixed solution and mineral oil into the PCR chambers, which were preloaded with the specified primers and probes. Subsequently, quantitative real-time PCR (qPCR) was carried out with the homemade instrument. Within 80 min, mycoplasma pneumoniae and its mutation type in the clinical samples were determined, which was verified by DNA sequencing. The easy-to-make and easy-to-use device provides a rapid and integrated detection approach for pathogens and antibiotic resistance mutations, which is urgently needed on the infection scene and in hospital emergency departments.

29 April 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
ZGZehang Gao
Zehang Gao
HPHuo Peng
Huo Peng
MZMinjie Zhu
Minjie Zhu
Lei WuLei Wu
Lei Wu
CJChunping Jia
Chunping Jia
JZJianlong Zhao
Jianlong Zhao
In droplet-based microfluidics, visualizing and modulating of droplets is often prerequisite. In this paper, we report a facile strategy for visualizing and modulating high-throughput droplets in microfluidics. In the strategy, by modulating the sampling frequency of a flash light with the droplet frequency, we are able to map a real high frequency signal to a low frequency signal, which facilitates visualizing and feedback controlling. Meanwhile, because of not needing synchronization signals, the strategy can be directly implemented on any droplet-based microfluidic chips. The only cost of the strategy is an additional signal generator. Moreover, the strategy can catch droplets with frequency up to several kilohertz, which covers the range of most high-throughput droplet-based microfluidics. In this paper, the principle, setup and procedure were introduced. Finally, as a demonstration, the strategy was also implemented in a miniaturized picoinjector in order to monitor and control the injection dosage to droplets. We expect that this facile strategy supplies a low-cost yet effective imaging system that can be easily implemented in miniaturized microfluidic systems or general laboratories.