Subsurface damage (SSD), having a great impact on the laser-induced damage threshold (LIDT) of ultra-smooth optics applied in high-power laser systems, should be tightly controlled. An improved total internal reflection microscopy (TIRM), combined with digital image processing techniques, is proposed to quantitatively inspect SSD. With the characteristic that there is a relatively small depth of field (DOF) for a microscope at high magnification (50×), a series of SSD images are captured along with the microscope focusing at different depths under the surface by means of micro-focusing control. The definition of each image is calculated through wavelet transformation. By simulation, the relationship between the definition of TIRM images and the depth of the SSD has been established. According to the definition curve, the SSD depth is acquired. Fused silica glasses polished after fine grinding are measured non-destructively by our TIRM setup. The results show that the improved TIRM is a useful method to evaluate SSD. It is helpful to improve the efficiency of optical fabrication.
In high-power laser systems, extrinsic impurities—particularly Ce introduced during conventional ring polishing—have been identified as critical contributors to the degradation of laser-induced damage resistance in fused silica optical components. This study systematically investigates the effects of cerium substitutional doping on the electronic structure and optical properties of fused silica, integrating first-principles density functional theory calculations with experimental characterizations. The results demonstrate that substitutional incorporation of cerium atoms into the fused silica framework introduces deep-level defect states within the band gap, resulting in band gap narrowing and absorption edge redshift of the material. The energy position of the defect states depends on the Ce doping configuration. Among them, the Ce-4f orbital constitutes the dominant component of the defect state’s electronic structure, while the neighboring atomic orbitals such as O-2p and Si-3s/3p participate in bonding through hybridization, thereby determining the depth and distribution characteristics of the defect levels. The optical absorption edge of cerium-doped fused silica undergoes a significant redshift from the intrinsic value of 222 nm to 468 nm in the dual-Ce adjacent-site doping configuration, thereby endowing the material with substantial optical absorption capability at a wavelength of 355 nm. μ-UVPL spectroscopy combined with μ-XRD and other characterization analyses confirmed that the characteristic emission peak at 450 nm on the surface region of fused silica originated from Ce-related defect centers; this spectral feature was consistent with the defect state electronic structure predicted by the diatomic nearest-neighbor doping model. LIDT tests further indicated that the Ce-contaminated area significantly weakened the material’s laser damage resistance under 355 nm laser irradiation. This study further explained the mechanism by which traditional polishing-induced Ce element doping causes the low laser damage threshold of fused silica optical components, providing a theoretical basis for improving their performance.
As precision polishing and post-processing advance, surface-layer absorptive defects in fused silica optics increasingly show random distribution, low quantity, and ultra-low concentration—making efficient, non-destructive inspection of large-aperture components challenging. In this study, fused silica samples made by conventional ring polishing and acid cleaning were analyzed using photothermal weak absorption (PTWA), micro-X-ray fluorescence (μ-XRF), micro-X-ray diffraction (μ-XRD), and ultraviolet fluorescence microscopy spectroscopy. Results show that process-related contaminants emit strong spontaneous fluorescence between 500 and 620 nm under 375 nm ultraviolet (UV) excitation. Using this optical signature, a high-throughput detection system was developed that combines rapid fluorescence imaging for screening with PTWA for verification. Full-area scanning of a 100 mm × 100 mm sample successfully identified absorptive defects with significantly improved efficiency over conventional methods. This work provides a practical quality control solution for large-aperture fused silica optics and supports process optimization to reduce laser damage risks in high-performance systems.