Ammar Salim Kadhum

Prof. Dr. Ammar Salim Kadhum

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2020 in Clinical and Experimental Dental Research
Verified
Journal Article
Open access
PDF file
AKAmmar Salim Kadhum
Ammar Salim Kadhum
AAAkram Faisal Alhuwaizi
Akram Faisal Alhuwaizi
Objectives: To investigate the efficacy of polyether‐ether‐ketone (PEEK) wire as a fixed orthodontic retainer, by comparing its performance to other retainer wires and optimizing its adhesion to composite bonding materials.Materials and methods: Retainer wires of 15 mm segments were used, PEEK wires were prepared in cylindrical form with 0.8 mm diameter, and had two surface treatments namely air‐abrasion and conditioning with adhesive system. Three different metallic retainer wires were used for comparison and three tests were performed; two tests measured debonding force and associated wire deflection from acrylic blocks and bovine teeth and one test for pull‐out force. To test debonding force, a vertically directed compressive force was applied to the retainer wires bonded to the acrylic blocks and bovine teeth, while for pull‐out test; a vertically directed tensile force detached the retainer wire.Results: In both debonding tests, PEEK wires (regardless the surface treatment) had non‐significant difference when compared to each other, or to the other metallic wires, except the dead‐soft coaxial wire group. The dead‐soft coaxial wire group had significant difference when compared to other groups regarding both the force magnitude and maximum deflection, the only exception was the debonding force of the flat braided retainer wires bonded to bovine teeth. In pull‐out test PEEK wires conditioned with adhesive system and the air‐abraded recorded the second and third highest readings respectively.Conclusions: Within the limitations of this study, the 0.8 mm round PEEK wires have comparable performance—in terms of debonding and pull out forces—to conventional retainers when bonded with 4 mm composite bonding spots; using air‐abrasion for 10 s at 3.5 MPa provided sufficient adhesion of the composite to the wire, and conditioning with adhesive system may provide no further clinical benefit.

1 January 2022 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
AIAli R. Issa
Ali R. Issa
AKAmmar Salim Kadhum
Ammar Salim Kadhum
SMShahbaa A. Mohammed
Shahbaa A. Mohammed
Objective. This study aimed to evaluate and compare the force degradation of two types of elastomeric chains following different periods of immersion in zinc‐containing mouthwashes. Materials and Methods. Four hundred and forty pieces of Elasto‐Force and Super Elasto‐Force elastomeric chains were divided into two control and eight experimental groups. The pieces were stretched to 25 mm on pins mounted on an acrylic block and stored in distilled water at 37°C. The experimental groups were immersed in four different types of mouthwash for one minute twice a day throughout the test period. Ten continuous thermocycles per day between cold and hot water baths (5–55°C) were carried out. Forces were measured at six‐time intervals (initial, 24 hours, 1, 3, 6, and 8 weeks). The mean force was calculated and compared among different elastomeric chains, mouthwashes, and times using the t‐test and one‐way ANOVA test followed by Tukey’s HSD test. The level of significance was set at 0.05. Results. Both types of elastomeric chains had significant force degradation over time (74–79% at 8 weeks). The Super Elasto‐Force generated a higher force level than the Elasto‐Force elastomeric chain at all time points. SmartMouth Clinical DDS mouthwash had a significantly lower effect on force degradation than other mouthwashes with no significant difference compared to control groups. Conclusions. Depending on these results: there is no clinically significant difference between both types of elastomeric chains, although Super Elasto‐Force delivered a higher force level. The pH of the mouthwashes could play a role in force degradation over time, rather than other ingredients including zinc. The SmartMouth mouthwash had the minimum effect on force degradation of elastomeric chains, followed by Halita, Listerine Total Care Zero, and Breath Rx, respectively.

29 August 2024 in European Journal of Orthodontics
Verified
Journal Article
Closed access
PDF file
EJEsraa Salman Jasim
Esraa Salman Jasim
AKAmmar Salim Kadhum
Ammar Salim Kadhum
Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys. To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC). A single-centre, two-arm parallel groups randomized clinical trial. The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6. Single blinding of participants. A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group. No harmful effects have been reported. Limited follow-up duration and the inability to blind the operator due to the nature of the intervention. After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction. https://register.clinicaltrials.gov. (NCT05557136).

5 December 2024 in SHIFAA
Verified
Journal Article
Open access
PDF file
YYYassir A. Yassir
Yassir A. Yassir
LKLayla S. Kadhum
Layla S. Kadhum
DADalia N. Al-Oboudi
Dalia N. Al-Oboudi
AKAmmar Salim Kadhum
Ammar Salim Kadhum
Purpose: This study aimed to assess the thickness of alveolar bone of maxillary and mandibular incisors from orthodontics perspective. Materials and Method: A total of 73 Cone beam computed tomography for Iraqi patients (47 females and 26 males) were included in this study. The selected images were captured and imported to AutoCAD database software to perform the measurement. To measure alveolar bone thickness, a reference line was drawn through the long axis of each incisor, from the incisal edge to the root apex. Then, labial and lingual/palatal perpendicular lines were drawn to the reference line at 3, 6, and 9mm apically from the cemento-enamel junction (CEJ). Results: The buccal bone is generally thinner than the lingual/palatal bone. The bone gets relatively thicker closer to the apex. The buccal bone for all lower incisors was less than 1 mm at 3- and 6-mm distance. It was slightly thicker at the central incisor as compared to the lateral at 9-mm distance. Genders have a difference in the thickness of the palatal alveolar bone in their right and left lateral incisors, which are 3mm and 9mm, respectively. Alveolar bone thickness is significantly positively correlated with several teeth. Conclusions: Males and females in this study showed comparable alveolar bone thickness. The alveolar bone thickness increased with increasing age. It is essential to assess the thickness of alveolar bone pre-orthodontic treatment (especially for patients with thin biotype, and those cases that involve labial proclination of the lower incisors).

25 July 2024 in Metals
Verified
Journal Article
Open access
PDF file
AAAhmed Muhsin Yousif Al-Mayali
Ahmed Muhsin Yousif Al-Mayali
AKAmmar Salim Kadhum
Ammar Salim Kadhum
TAThair L. Alzubaydi
Thair L. Alzubaydi
The aim of this study is to investigate the antibacterial capabilities of different coating durations of three nanoparticle (NP) coatings: molybdenum (Mo), tantalum (Ta), and zinc oxide (ZnO), and their effects on the surface characteristics of 316L stainless steel (SS). The coated substrates underwent characterization utilizing field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectrometry (EDX), and X-ray diffractometer (XRD) techniques. The antibacterial efficacy of NPs was evaluated using the agar diffusion method. The FE-SEM and EDX images confirmed the presence of nano-sized particles of Mo, Ta, and ZnO on the surface of the substrates with perfectly symmetrical spheres and a uniform distribution of the NPs. All groups demonstrated antibacterial activity, and the ability to inhibit the growth of Streptococcus mutans and Lactobacillus acidophilus bacteria. The ZnO group had the most potent antibacterial effect, followed by the Mo group, while the Ta group had the least effect. A direct-current (DC) plasma sputtering system was used to produce nano-coatings of high purity that were homogeneous, crack-free and showed no sign of delamination. Bacterial strains exposed to Mo, Ta, and ZnO coated surfaces exhibited a significant loss of viability in a time-dependent manner. The optimum sputtering time to ensure the best antibacterial properties and preserve the resources was 1 hour (h) for Mo, 3 h for Ta and 6 h for ZnO.

16 December 2019 in The Saudi Dental Journal
Verified
Journal Article
Open access
YYYassir A. Yassir
Yassir A. Yassir
AKAmmar Salim Kadhum
Ammar Salim Kadhum
HSHayder F. Saloom
Hayder F. Saloom
GMGrant T. McIntyre
Grant T. McIntyre
DBDavid R. Bearn
David R. Bearn
Objective: To develop Orthodontic Patient Information Leaflets (PILs) in Arabic. Material & method This study included five phases starting with Arabic translation of existing British Orthodontic Society leaflets; initial face validation with three orthodontists; content validation with ten orthodontists; final face validation with ten orthodontists, five postgraduate students, and ten patients; and re-translation to English prior to comparing the new documents with the original PILs to verify that all the necessary information were included. The content validity index (CVI) assessed item level (I-CVI) and scale level (S-CVI). Results: The three Arabic PILs were face validated with inclusion of mini-screws, rapid maxillary expansion, and interproximal reduction. Content validity was perfect with no item I-CVI < 0.80. The S-CVI/Ave for PIL Fixed Appliances = 0.98, PIL Removable Appliances = 0.98 and PIL Functional Appliances = 0.97. In the final face validation, the three leaflets received 100% agreement from all observers for consistency of leaflet format and style, clarity, readability and use of adequate phrases. Finally, the leaflets were re-translated and the information was checked by native English speakers to ensure the completeness of information. There were no discrepancies and face validity was excellent. Conclusion: Valid PILs for Arabic-speaking patients undergoing orthodontic treatment with fixed, removable, and functional appliances have been developed.