Cecilia Villa Etchegoyen

Dr. Cecilia Villa Etchegoyen

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 May 2019 in Nutrients
Verified
Journal Article
Open access
PDF file
CECecilia Villa Etchegoyen
Cecilia Villa Etchegoyen
MLMercedes Lombarte
Mercedes Lombarte
NMNatalia Matamoros
Natalia Matamoros
JBJose Belizan
Jose Belizan
GCGabriela Cormick
Gabriela Cormick
There is increasing epidemiologic and animal evidence that a low calcium diet increases blood pressure. The aim of this review is to compile the information on the link between low calcium intake and blood pressure. Calcium intake may regulate blood pressure by modifying intracellular calcium in vascular smooth muscle cells and by varying vascular volume through the renin–angiotensin–aldosterone system. Low calcium intake produces a rise of parathyroid gland activity. The parathyroid hormone increases intracellular calcium in vascular smooth muscles resulting in vasoconstriction. Parathyroidectomized animals did not show an increase in blood pressure when fed a low calcium diet as did sham-operated animals. Low calcium intake also increases the synthesis of calcitriol in a direct manner or mediated by parathyroid hormone (PTH). Calcitriol increases intracellular calcium in vascular smooth muscle cells. Both low calcium intake and PTH may stimulate renin release and consequently angiotensin II and aldosterone synthesis. We are willing with this review to promote discussions and contributions to achieve a better understanding of these mechanisms, and if required, the design of future studies.

1 September 2026 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
OCOwen R. Crystal
Owen R. Crystal
JFJuan M Farina
Juan M Farina
ISIsabel Grace Scalia
Isabel Grace Scalia
CAChadi Ayoub
Chadi Ayoub
CECecilia Villa Etchegoyen
Cecilia Villa Etchegoyen
IBImon Banerjee
Imon Banerjee
BACKGROUND: Accurate assessment of left ventricular outflow tract (LVOT) gradients is critical for hypertrophic cardiomyopathy management, yet Doppler-based measurements are technically demanding and require expertise. The objective of this work was to develop a multi-view deep learning model capable of classifying LVOT obstruction (>20 mm Hg) using routine 2-dimensional echocardiographic windows without reliance on Doppler imaging. METHODS: We trained and externally validated a cross-attention-based video-to-video fusion framework that integrated EchoPrime-derived video representations from 3 standard transthoracic echocardiographic views to classify LVOT gradients. RESULTS: Training was performed on a derivation cohort (N=1833) from a tertiary care system in the United States, with model performance evaluated on an internally held-out test set (N=275) and a Korean external validation cohort (N=46). Single-view baselines showed limited discrimination (external area under the receiver operating curves, 0.47–0.70). Conversely, the domain-specific foundational model (EchoPrime) achieved superior single-view performance (area under the receiver operating curves, 0.75–0.80 internal; 0.79–0.83 external), highlighting the importance of echo-specific pretraining and temporal modeling. The proposed multi-view fusion further enhanced predictive performance, with the late fusion model reaching an area under the receiver operating curve of 0.84 on the external cohort with significant population-shift. CONCLUSIONS: These results suggest LVOT physiology is encoded in routine 2-dimensional imaging and can be leveraged for clinically relevant gradient classification without Doppler input. The proposed artificial intelligence-guided strategy demonstrates substantial cost savings compared with the screen-all approach. By integrating complementary spatial-temporal information across multiple views, our approach generalizes robustly across populations and may enable real-time decision support, extend LVOT assessment to portable or resource-limited settings, and complement Doppler-based evaluation for longitudinal hypertrophic cardiomyopathy management.

13 August 2026 in BMJ Open
Verified
Journal Article
Open access
PDF file
OIOmar H Ibrahim
Omar H Ibrahim
JFJuan Farina
Juan Farina
MPMilagros Pereyra Pietri
Milagros Pereyra Pietri
KAKamal Awad
Kamal Awad
MAMohammed Tiseer Abbas
Mohammed Tiseer Abbas
CAChadi Ayoub
Chadi Ayoub
Objective: To compare the diagnostic accuracy of four available automated electronic medical record (EMR) retrieval methods, including a large language model (LLM)-assisted workflow, against manual chart adjudication for identifying cardiovascular events. Design: Retrospective diagnostic accuracy study. Setting: Three sites within a single US tertiary health system. Participants: Two adult cohorts with previously adjudicated cardiovascular outcomes were included. Cohort 1 included 2258 patients treated with immune checkpoint inhibitors, and Cohort 2 included 1426 patients who underwent transcatheter aortic valve replacement. Primary and secondary outcome measures: The reference standard was clinician manual chart adjudication. Outcomes included ischaemic stroke or transient ischaemic attack, myocardial infarction (MI), heart failure (HF) exacerbation or hospitalisation and a composite major adverse cardiovascular events (MACE) outcome. Automated retrieval methods included International Classification of Diseases (ICD) codes, primary diagnosis, problem list and a zero-shot LLM workflow. Area under the (receiver operating characteristic) curve (AUC), sensitivity, specificity and net reclassification improvement were assessed. Results: In Cohort 1, the LLM achieved the highest AUC for stroke (0.920; 95% CI 0.881 to 0.958), MI (0.938; 95% CI 0.905 to 0.971) and composite MACE (0.880; 95% CI 0.854 to 0.907), whereas ICD-based retrieval had a higher AUC for HF (0.882; 95% CI 0.845 to 0.918 vs 0.873; 95% CI 0.831 to 0.914). In Cohort 2, the LLM achieved the highest AUC for all evaluated outcomes: stroke (0.915; 95% CI 0.862 to 0.968), MI (0.928; 95% CI 0.839 to 1.000), HF (0.844; 95% CI 0.803 to 0.884) and composite MACE (0.862; 95% CI 0.829 to 0.895). In Cohort 1, differences in AUC between the LLM and ICD methods were not statistically significant across outcomes, whereas in Cohort 2 the LLM showed significantly higher AUC for stroke and composite MACE. Conclusion: In this multisite retrospective validation study, the LLM-assisted workflow showed strong but context-dependent performance for identifying cardiovascular events from the EMR. Performance varied by outcome and cohort, and ICD-based retrieval remained competitive for some use cases. These findings support a complementary role for LLM-assisted extraction in retrospective cardiovascular outcomes research.

14 June 2026 in Medicina
Verified
Journal Article
Open access
PDF file
Abdelrahman HafezAbdelrahman Hafez
Abdelrahman Hafez
KAKamal Awad
Kamal Awad
JFJuan M Farina
Juan M Farina
MNMohamed Nour
Mohamed Nour
MMMohamed Reyad Mohamed
Mohamed Reyad Mohamed
RAReza Arsanjani
Reza Arsanjani
Coronary artery disease (CAD) remains a leading cause of global morbidity and mortality. Accurate diagnosis of ischemia-causing coronary stenoses is essential for guiding revascularization and improving outcomes. Although invasive fractional flow reserve (FFR) remains the gold standard for functional lesion assessment, its use is limited by procedural invasiveness, cost, and complexity. CT-derived FFR (FFRct), based on computational fluid dynamics (CFD), was the first major advance in noninvasive physiological assessment, but its adoption has been hindered by intensive off-site computation and dependence on high-quality imaging. This review summarizes the evolution from invasive FFR to AI-driven functional assessment of coronary lesions. We examine the principles and validation of CFD-based FFRct and then focus on the shift toward artificial intelligence, including both machine learning (ML) and deep learning (DL) approaches. These methods range from models using engineered geometric and plaque features trained on large synthetic datasets to end-to-end systems that learn directly from imaging data. We discuss key validation studies evaluating diagnostic accuracy, prognostic value, and clinical utility, with attention to performance in challenging settings such as intermediate stenoses, heavy calcification, and patients with comorbidities. We also highlight major barriers to widespread adoption, including dependence on input data quality, limited explainability, regulatory hurdles, and integration into clinical workflows. Finally, we outline future directions, including AI-enabled virtual PCI planning, multimodal risk stratification, and broader access to functional cardiac assessment. AI has the potential to transform noninvasive coronary imaging by enabling a single CCTA scan to provide rapid, integrated evaluation of anatomy, plaque characteristics, and physiological significance, supporting more personalized care and better clinical outcomes.

5 October 2026 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
EHEiad Habib
Eiad Habib
AMArshad Mohammed
Arshad Mohammed
MGMichael Gotway
Michael Gotway
AWAlyssa Wallace
Alyssa Wallace
HNHussein Abdul Nabi
Hussein Abdul Nabi
KSKomandoor Srivathsan
Komandoor Srivathsan

2 July 2026 in JTCVS Open
Verified
Journal Article
Open access
DJDawn E Jaroszewski
Dawn E Jaroszewski
CECecilia Villa Etchegoyen
Cecilia Villa Etchegoyen
JFJuan M. Farina
Juan M. Farina
CWCourtney Wheatley-Guy
Courtney Wheatley-Guy
NONour Odeh
Nour Odeh
RAReza Arsanjani
Reza Arsanjani