Alberto Bacci

Dr. Alberto Bacci

Istituto Nazionale di Fisica Nucleare (INFN), Via Celoria, 16, 20133 Milano, Italy

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2025 in The European Physical Journal C
Verified
Journal Article
Open access
MBM. Benedikt
M. Benedikt
FZF. Zimmermann
F. Zimmermann
BAB. Auchmann
B. Auchmann
WBW. Bartmann
W. Bartmann
JBJ. P. Burnet
J. P. Burnet
MZM. Zykova
M. Zykova
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.

5 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VPVittoria Petrillo
Vittoria Petrillo
IDIllya Drebot
Illya Drebot
MRMarcel Ruijter
Marcel Ruijter
SSSanae Samsam
Sanae Samsam
Alberto BacciAlberto Bacci
Alberto Bacci
LSLuca Serafini
Luca Serafini
In this paper, we present the generalities of the Compton interaction process; we analyse the different paradigms of Inverse Compton Sources, implemented or in commissioning phase at various facilities, or proposed as future projects. We present an overview of the state of the art, with a discussion of the most demanding challenges.

10 September 2019 in Instruments
Verified
Journal Article
Open access
PDF file
IDIllya Drebot
Illya Drebot
Alberto BacciAlberto Bacci
Alberto Bacci
ABAngelo Bosotti
Angelo Bosotti
FBFrancesco Broggi
Francesco Broggi
FCFrancesco Canella
Francesco Canella
LSLuca Serafini
Luca Serafini
We present a conceptual design for a compact X-ray Source BriXS (Bright and compact X-ray Source). BriXS, the first stage of the Marix project, is an Inverse Compton Source (ICS) of X-ray based on superconducting cavities technology for the electron beam with energy recirculation and on a laser system in Fabry-Pérot cavity at a repetition rate of 100 MHz, producing 20–180 keV monochromatic X-Rays devoted mainly to medical applications. An energy recovery scheme based on a modified folded push-pull CW-SC twin Energy Recovery Linac (ERL) ensemble allows us to sustain an MW-class beam power with almost one hundred kW active power dissipation/consumption.

1 March 2014 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
Alberto BacciAlberto Bacci
Alberto Bacci
ARA.R. Rossi
A.R. Rossi

13 November 2019 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
Alberto BacciAlberto Bacci
Alberto Bacci
Marcello Rossetti ContiMarcello Rossetti Conti
Marcello Rossetti Conti
ABA. Bosotti
A. Bosotti
SCS. Cialdi
S. Cialdi
Simone Di MitriSimone Di Mitri
Simone Di Mitri
LSL. Serafini
L. Serafini
We present a design study of an innovative scheme to generate high rep rate (MHz-class) GeV electron beams by adopting a two-pass two-way acceleration in a superconducting (SC) linac operated in continuous wave (CW) mode. The electron beam is accelerated twice by being reinjected in opposite direction of propagation into the linac after the first passage. Acceleration in opposite directions is accomplished thanks to standing waves supported in rf cavities. The task of recirculating the electron beam when it leaves the linac after first pass is performed by a bubble-shaped arc compressor composed by a sequence of double bend achromat. In this paper we address the main issues inherent to the two-pass acceleration process and the preservation of the electron beam quality parameters (emittance, energy spread, peak current) required to operate x-ray free electron lasers (FEL) with low jitters in the amplitude, spectral and temporal domain, as achieved by operating in seeding and/or oscillator mode a CW FEL up to 1 MHz rep rate. Detailed start-to-end simulations are shown to assess the capability of this new scheme to double the electron beam energy as well as to compress the electron bunch length from picoseconds down to tens of femtoseconds. The advantage of such a scheme is to halve the requested linac length for the same final electron beam energy, which is typically in the few GeV range, as needed to drive an x-ray FEL. The AC power to supply the cryogenic plant is also significantly reduced with respect to a conventional single-pass SC linac for the same final energy. We are reporting also x-ray FEL simulations for typical values of wavelengths of interest (in the 200 eV-8 keV photon energy range) to better illustrate the potentiality of this new scheme.

24 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MOMichele Opromolla
Michele Opromolla
Alberto BacciAlberto Bacci
Alberto Bacci
MCMarcello Rossetti Conti
Marcello Rossetti Conti
ARAndrea Renato Rossi
Andrea Renato Rossi
GRGiorgio Rossi
Giorgio Rossi
VPVittoria Petrillo
Vittoria Petrillo
Fine time-resolved analysis of matter—that is, spectroscopy and photon scattering—in the linear response regime requires fs-scale pulsed, high repetition rate, fully coherent X-ray sources. A seeded Free-Electron Laser, driven by a linac based on Super Conducting cavities, generating 108–1010 coherent photons at 2–5 keV with 0.2–1 MHz of repetition rate, can address this need. The scheme proposed is a Free-Electron Laser Oscillator at 3 keV, working with a cavity based on X-ray mirrors. The whole chain of the X-ray generation is here described by means of start-to-end simulations.