Marcello Rossetti Conti

Dr. Marcello Rossetti Conti

Istituto Nazionale di Fisica Nucleare, Milan Section
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2018 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
MFM. Ferrario
M. Ferrario
DAD. Alesini
D. Alesini
MAM.P. Anania
M.P. Anania
MAM. Artioli
M. Artioli
ABA. Bacci
A. Bacci
MZM. Zobov
M. Zobov

24 December 2025 in The European Physical Journal C
Verified
Journal Article
Open access
MBM. Benedikt
M. Benedikt
FZF. Zimmermann
F. Zimmermann
BAB. Auchmann
B. Auchmann
WBW. Bartmann
W. Bartmann
JBJ. P. Burnet
J. P. Burnet
MZM. Zykova
M. Zykova
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.

1 June 2019 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LSL. Serafini
L. Serafini
ABA. Bacci
A. Bacci
ABA. Bellandi
A. Bellandi
MBM. Bertucci
M. Bertucci
MBM. Bolognesi
M. Bolognesi
GRG. Rossi
G. Rossi

1 September 2016 in Physical Review Accelerators and Beams
Verified
Journal Article
Open access
PDF file
DMD. Micieli
D. Micieli
IDI. Drebot
I. Drebot
ABA. Bacci
A. Bacci
EME. Milotti
E. Milotti
VPVittoria Petrillo
Vittoria Petrillo
LSL. Serafini
L. Serafini
We present the design of a photon-photon collider based on conventional Compton gamma sources for the observation of elastic γγ scattering. Two symmetric electron beams, generated by photocathodes and accelerated in linacs, produce two primary gamma rays through Compton backscattering with two high energy lasers. The elastic photon-photon scattering is analyzed by start-to-end simulations from the photocathodes to the detector. A new Monte Carlo code has been developed ad hoc for the counting of the QED events. Realistic numbers of the secondary gamma yield, obtained by using the parameters of existing or approved Compton devices, a discussion of the feasibility of the experiment and of the nature of the background are presented.

5 January 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VPVittoria Petrillo
Vittoria Petrillo
IDIllya Drebot
Illya Drebot
MRMarcel Ruijter
Marcel Ruijter
SSSanae Samsam
Sanae Samsam
Alberto BacciAlberto Bacci
Alberto Bacci
LSLuca Serafini
Luca Serafini
In this paper, we present the generalities of the Compton interaction process; we analyse the different paradigms of Inverse Compton Sources, implemented or in commissioning phase at various facilities, or proposed as future projects. We present an overview of the state of the art, with a discussion of the most demanding challenges.

10 September 2019 in Instruments
Verified
Journal Article
Open access
PDF file
IDIllya Drebot
Illya Drebot
Alberto BacciAlberto Bacci
Alberto Bacci
ABAngelo Bosotti
Angelo Bosotti
FBFrancesco Broggi
Francesco Broggi
FCFrancesco Canella
Francesco Canella
LSLuca Serafini
Luca Serafini
We present a conceptual design for a compact X-ray Source BriXS (Bright and compact X-ray Source). BriXS, the first stage of the Marix project, is an Inverse Compton Source (ICS) of X-ray based on superconducting cavities technology for the electron beam with energy recirculation and on a laser system in Fabry-Pérot cavity at a repetition rate of 100 MHz, producing 20–180 keV monochromatic X-Rays devoted mainly to medical applications. An energy recovery scheme based on a modified folded push-pull CW-SC twin Energy Recovery Linac (ERL) ensemble allows us to sustain an MW-class beam power with almost one hundred kW active power dissipation/consumption.