Na Chen

Prof. Na Chen

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2007 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
BYBinfeng Yun
Binfeng Yun
NCNa Chen
Na Chen
YCYiping Cui
Yiping Cui
A highly sensitive liquid-level sensor based on etched fiber Bragg grating (FBG) is proposed and demonstrated. The transmission dips of FBG spectra are affected by the fraction of the length of the etched FBG that is surrounded by the liquid. The experiments show that for a liquid-level variation of 24 mm, the transmission dip difference changes about 32 dB. Also in the linear region, a high sensitivity of 2.56 dB/mm is achieved.

23 July 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
DFDengfeng Fan
Dengfeng Fan
CMChengbo Mou
Chengbo Mou
XBXuekun Bai
Xuekun Bai
SWShaofei Wang
Shaofei Wang
NCNa Chen
Na Chen
XZXianglong Zeng
Xianglong Zeng
We demonstrate an all-fiber passively Q-switched erbium-doped fiber laser (EDFL) using a gold-nanosphere (GNS) based saturable absorber (SA) with evanescent field interaction. Using the interaction of evanescent field for fabricating SAs, long nonlinear interaction length of evanescent wave and GNSs can be achieved. The GNSs are synthesized from mixing solution of chloroauricacid (HAuCl4) and sodium citrate by the heating effects of the microfiber’s evanescent field radiation. The proposed passively Q-switched EDFL could give output pulses at 1562 nm with pulse width of 1.78 μs, a repetition rate of 58.1 kHz, a pulse energy of 133 nJ and a output power of 7.7 mW when pumped by a 980 nm laser diode of 237 mW.

30 November 2016 in Sensors
Verified
Journal Article
Open access
PDF file
TZTongzhi Zhang
Tongzhi Zhang
Fufei PangFufei Pang
Fufei Pang
Huanhuan LiuHuanhuan Liu
Huanhuan Liu
JCJiajing Cheng
Jiajing Cheng
LLLongbao Lv
Longbao Lv
TWTingyun Wang
Tingyun Wang
We have proposed and demonstrated a Michelson interferometer-based fiber sensor for detecting acoustic emission generated from the partial discharge (PD) of the accessories of a high-voltage cable system. The developed sensor head is integrated with a compact and relatively high sensitivity cylindrical elastomer. Such a sensor has a broadband frequency response and a relatively high sensitivity in a harsh environment under a high-voltage electric field. The design and fabrication of the sensor head integrated with the cylindrical elastomer is described, and a series of experiments was conducted to evaluate the sensing performance. The experimental results demonstrate that the sensitivity of our developed sensor for acoustic detection of partial discharges is 1.7 rad / ( m ⋅ Pa ) . A high frequency response up to 150 kHz is achieved. Moreover, the relatively high sensitivity for the detection of PD is verified in both the laboratory environment and gas insulated switchgear. The obtained results show the great potential application of a Michelson interferometer-based fiber sensor integrated with a cylindrical elastomer for in-situ monitoring high-voltage cable accessories for safety work.

1 July 2017 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
NCNa Chen
Na Chen
MRMing Rong
Ming Rong
XSXiaoguang Shao
Xiaoguang Shao
HZHeng Zhang
Heng Zhang
SLShupeng Liu
Shupeng Liu
JPJiahua Pan
Jiahua Pan
The surface-enhanced Raman spectroscopy (SERS) of blood serum was investigated to differentiate between prostate cancer (PCa) and benign prostatic hyperplasia (BPH) in males with a prostate-specific antigen level of 4–10 ng/mL, so as to reduce unnecessary biopsies. A total of 240 SERS spectra from blood serum were acquired from 40 PCa subjects and 40 BPH subjects who had all received prostate biopsies and were given a pathological diagnosis. Multivariate statistical techniques, including principal component analysis (PCA) and linear discriminant analysis (LDA) diagnostic algorithms, were used to analyze the spectra data of serum from patients in control (CTR), PCa and BPH groups; results offered a sensitivity of 97.5%, a specificity of 100.0%, a precision of 100.0% and an accuracy of 99.2% for CTR; a sensitivity of 90.0%, a specificity of 97.5%, a precision of 94.7% and an accuracy of 98.3% for BPH; a sensitivity of 95.0%, a specificity of 93.8%, a precision of 88.4% and an accuracy of 94.2% for PCa. Similarly, this technique can significantly differentiate low- and high-risk PCa with an accuracy of 92.3%, a specificity of 95% and a sensitivity of 89.5%. The results suggest that analyzing blood serum using SERS combined with PCA–LDA diagnostic algorithms is a promising clinical tool for PCa diagnosis and assessment.

13 February 2014 in IEEE Photonics Technology Letters
Verified
Journal Article
Open access
ZCZhenyi Chen
Zhenyi Chen
ZDZhangmin Dai
Zhangmin Dai
NCNa Chen
Na Chen
SLShupeng Liu
Shupeng Liu
FPFufei Pang
Fufei Pang
TWTingyun Wang
Tingyun Wang
This letter presents a surface-enhanced Raman scattering (SERS) nanoprobe based on gold nanoparticles-modified tapered optical fiber and demonstrates its ability to perform remote Raman detection. The nanoscale tapered fiber with the tip size of 40.7 nm was made by heated pulling and chemical etching methods. The gold nanoparticles, prepared beforehand by the Frens method with a microwave heating process, were deposited on the tapered surface of the nanoprobe with the electrostatic self-assembly technology. Raman spectra of Rhodamine 6G (R6G) molecules were measured, using this SERS nanoprobe in an optrode remote detection mode. Considerably high signal-to-noise ratio and high sensitivity were achieved. The detection limit for R6G aqueous solution reaches 10-8 mol/L.

7 March 2011 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FPFufei Pang
Fufei Pang
HLHuanhuan Liu
Huanhuan Liu
HGHairun Guo
Hairun Guo
YLYunqi Liu
Yunqi Liu
XZXianglong Zeng
Xianglong Zeng
TWTingyun Wang
Tingyun Wang
An in-fiber Mach-Zehnder interferometer (MZI) was fabricated and characterized for solution refractive index (RI) sensors. The MZI consists of two cascade double cladding fibers (DCFs) in a standard single mode fiber (SMF). The DCFs serve as the in-fiber couplers which split and combine light propagating in the core and the outer cladding region. Since the cladding mode is excited, the interference spectrum is sensitive to the ambient RI variation. Within the RI range from 1.3333 to 1.4535, the sensor characteristics were characterized. The sensitivity of 31 nm/RIU and 823 nm/RIU were obtained for the lower RI (1.34) and the higher RI (1.44), respectively. With the mass-producing of DCF and the easy fabrication process of the sensor head, the proposed in-fiber MZI is a potential alternative for the RI sensor application.