Malik Asia Naz

Dr. Malik Asia Naz


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in European Journal of Medicinal Chemistry
Verified
Journal Article
Closed access
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
IAIsmail I. Althagafi
Ismail I. Althagafi
MNMalik Asia Naz
Malik Asia Naz

1 May 2011 in European Journal of Medicinal Chemistry
Verified
Journal Article
Closed access
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
MNMalik Asia Naz
Malik Asia Naz

7 March 2022 in Molecular Biology Reports
Verified
Journal Article
Closed access
PDF file
MNMalik Asia Naz
Malik Asia Naz
RBRowaida Bakri
Rowaida Bakri
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza

1 July 2010 in European Journal of Medicinal Chemistry
Verified
Journal Article
Closed access
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
MAM. Saeed Arayne
M. Saeed Arayne
NSNajma Sultana
Najma Sultana
FQFaiza Qureshi
Faiza Qureshi
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
NRNadia Rehman
Nadia Rehman

12 August 2013 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
NSNawab Sher
Nawab Sher
AZArif Zubair
Arif Zubair
MNMalik Asia Naz
Malik Asia Naz
NSNighat Shafi
Nighat Shafi
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
A robust method, for the chromatographic separation of three antidiabetic drugs viz metformin, pioglitazone and glimepiride using an isocratic reversed phase high-performance liquid chromatographic (HPLC) system having ultraviolet detection at 254 nm is presented in this paper. The method was developed in human serum and dosage formulation with high-quality chromatographic separation between the drug peaks by using a stainless steel analytical column Nucleosil, C18 (10 micron, 25 × 0.46 cm). The system was operated at room temperature using a mobile phase consisting of acetonitrile, phosphate buffer (pH 4.3) in the ratio of 60 : 40 v/v at a flow rate of 1 mL min−1. The parametric statistics, i.e., correlation coefficient of 0.999 was assessed for all the drugs having linearity over the tested concentration range (10 to 10 000 ng mL−1) in human serum. The accuracy and the relative standard deviations of samples for six replicate measurements were not less than 97% and greater than 2%, respectively. The proposed method was validated for selectivity, linearity, accuracy, and precision according to the International Conference on Harmonization (ICH). The method is applicable for the quality control of the mentioned drugs in raw material, bulk drug, and pharmaceutical formulations as well as in human serum.

1 May 2017 in Journal of Molecular Graphics and Modelling
Verified
Journal Article
Closed access
MBMajdi M. Bkhaitan
Majdi M. Bkhaitan
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
MNMalik Asia Naz
Malik Asia Naz
HAHamed I. Ali
Hamed I. Ali