Nawab Sher

Nawab Sher

Auto-generated profile, based on publicly available information

Nawab Sher

Department of Chemistry, Faculty of Science, University of Karachi, Karachi 75270, Pakistan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
NSNawab Sher
Nawab Sher
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
NHNajmul Hasan
Najmul Hasan
NSNighat Shafi
Nighat Shafi
AZArif Zubair
Arif Zubair
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
This article describes a new, accurate and highly specific high performance liquid chromatographic method with UV detection (HPLC-UV) for the simultaneous determination of cetirizine HCl (CZ), chlorphenamine maleate (CPM), loratadine (LTD), domperidone (DP), buclizine (BZ) and meclizine (MZ) in pharmaceutical dosage form and human serum, involving pyridoxine (PYD) as the internal standard. The mobile phase consists of heptane sulphonic acid salt buffer and acetonitrile, drawn at a flow rate of 1.0 mL min−1 using a symmetry C18 column with UV detection at 230 nm. The intraday and inter-day precision measurements showed coefficients of variation always less than one. The calibration curve was tested in the range of 10–2150 ng mL−1 and the correlation coefficient of >0.9990 in all cases was obtained. The averages of the absolute and relative recoveries were found to be in the range of 98 to 102%. Up to six antihistamines were separated in the same chromatogram with good resolution. The proposed HPLC method has reasonable applications in pharmaceutical tablet dosage form and pharmacokinetics studies.

12 August 2013 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
NSNawab Sher
Nawab Sher
AZArif Zubair
Arif Zubair
MNMalik Asia Naz
Malik Asia Naz
NSNighat Shafi
Nighat Shafi
AMAgha Zeeshan Mirza
Agha Zeeshan Mirza
A robust method, for the chromatographic separation of three antidiabetic drugs viz metformin, pioglitazone and glimepiride using an isocratic reversed phase high-performance liquid chromatographic (HPLC) system having ultraviolet detection at 254 nm is presented in this paper. The method was developed in human serum and dosage formulation with high-quality chromatographic separation between the drug peaks by using a stainless steel analytical column Nucleosil, C18 (10 micron, 25 × 0.46 cm). The system was operated at room temperature using a mobile phase consisting of acetonitrile, phosphate buffer (pH 4.3) in the ratio of 60 : 40 v/v at a flow rate of 1 mL min−1. The parametric statistics, i.e., correlation coefficient of 0.999 was assessed for all the drugs having linearity over the tested concentration range (10 to 10 000 ng mL−1) in human serum. The accuracy and the relative standard deviations of samples for six replicate measurements were not less than 97% and greater than 2%, respectively. The proposed method was validated for selectivity, linearity, accuracy, and precision according to the International Conference on Harmonization (ICH). The method is applicable for the quality control of the mentioned drugs in raw material, bulk drug, and pharmaceutical formulations as well as in human serum.

8 July 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
NSNawab Sher
Nawab Sher
NSNighat Shafi
Nighat Shafi
ASAlisha Wafa Sial
Alisha Wafa Sial
MAMansoor Ahmad
Mansoor Ahmad
HNHuma Naseem
Huma Naseem
RP-HPLC ultraviolet detection simultaneous quantification of piracetam and levetiracetam has been developed and validated. The chromatography was obtained on a Nucleosil C18 column of25 cm×0.46 cm, 10 μm, dimension. The mobile phase was a (70 : 30 v/v) mixture of 0.1 g/L of triethylamine and acetonitrile. Smooth flow of mobile phase at 1 mL/min was set and 205 nm wavelength was selected. Results were evaluated through statistical parameters which qualify the method reproducibility and selectivity for the quantification of piracetam, levetiracetam, and their impurities hence proving stability-indicating properties. The proposed method is significantly important, permitting the separation of the main constituent piracetam from levetiracetam. Linear behavior was observed between 20 ng/mL and 10000 ng/mL for both drugs. The proposed method was checked in bulk drugs, dosage formulations, physiological condition, and clinical investigations and excellent outcome was witnessed.

19 February 2015 in Journal of Liquid Chromatography & Related Technologies
Verified
Journal Article
Closed access
NSNawab Sher
Nawab Sher
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
NFNasreen Fatima
Nasreen Fatima
SPShahnaz Perveen
Shahnaz Perveen
NSNighat Shafi
Nighat Shafi
This article pertains to development and validation of a low cost, fast, sensitive, and accurate RP-HPLC method for quantitative analysis of HZ. A Hibar μBondapak C18 column as the stationary phase and acetonitrile:methanol:buffer (500:200:300) as the mobile phase were used to accomplish the separation, when drawn at a flow rate of 1.0 mL/min, with 235 nm as monitoring wavelength. Linearity was established by studying the drug over the concentration range of 10–10000 ng mL−1, correlation coefficient of r = 0.9993, drug recovery (97 to 102%), and high reproducibility in serum samples (less than 2.5% RSD) displayed excellent linearity, accuracy, and precision. Force degradation studies of the drug under various stress conditions (acid, base, oxidation, photo, and thermal) proved the stability indicating power of the method. Substantial method validation study was carried out inline with ICH guidelines and was applied successfully to quantify the amount of HZ in bulk, pharmaceutical formulations, and blood serum samples.

31 August 2016 in The Open Medicinal Chemistry Journal
Verified
Journal Article
Open access
PDF file
NHNajmul Hasan
Najmul Hasan
MCMathurot Chaiharn
Mathurot Chaiharn
UTUmair Ali Toor
Umair Ali Toor
ZMZulfiqar Ali Mirani
Zulfiqar Ali Mirani
GSGhulam Sajjad
Ghulam Sajjad
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
In this article we describe development and validation of stability indicating, accurate, specific, precise and simple Ion-pairing RP-HPLC method for simultaneous determination of paracetamol and cetirizine HCl along with preservatives i.e. propylparaben, and methylparaben in pharmaceutical dosage forms of oral solution and in serum. Acetonitrile: Buffer: Sulfuric Acid (45:55:0.3 v/v/v) was the mobile phase at flow rate 1.0 mL min-1 using a Hibar® Lichrosorb® C18 column and monitored at wavelength of 230nm. The averages of absolute and relative recoveries were found to be 99.3%, 99.5%, 99.8% and 98.7% with correlation coefficient of 0.9977, 0.9998, 0.9984, and 0.9997 for cetirizine HCl, paracetamol, methylparaben and Propylparaben respectively. The limit of quantification and limit of detection were in range of 0.3 to 2.7 ng mL-1 and 0.1 to 0.8 ng mL-1 respectively. Under stress conditions of acidic, basic, oxidative, and thermal degradation, maximum degradation was observed in basic and oxidative stress where a significant impact was observed while all drugs were found almost stable in the other conditions. The developed method was validated in accordance with ICH and AOAC guidelines. The proposed method was successfully applied to quantify amount of paracetamol, cetirizine HCl and two most common microbial preservatives in bulk, dosage form and physiological fluid.

22 April 2016 in Instrumentation Science & Technology
Verified
Journal Article
Closed access
NSNawab Sher
Nawab Sher
NFNasreen Fatima
Nasreen Fatima
SPShahnaz Perveen
Shahnaz Perveen
FSFarhan Ahmed Siddiqui
Farhan Ahmed Siddiqui
A liquid chromatographic method is described for the quantification of prednisolone, benzimidazoles, and preservatives using a C18 analytical column as stationary phase. The mobile phase was 30:70 methanol:pH 2.5 phosphate buffer at a flow rate of 1.0 mL min−1 with absorbance detection at 235 nm. The method was linear for concentrations ranged from 40–10,000 ng mL−1. Low values of coefficient of variance were obtained when samples were analyzed as replicates. Excellent recovery values were recorded in commercial products and fortified samples. International Conference of Harmonization protocols were employed to perform comprehensive method validation. The reported method has applications for pharmaceutical and serum samples.