Jun Tao

Dr. Jun Tao


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2023 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
HSHongtao Sheng
Hongtao Sheng
QZQianlong Zhu
Qianlong Zhu
JTJun Tao
Jun Tao
HZHuaying Zhang
Huaying Zhang
FPFeixiang Peng
Feixiang Peng

17 April 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
DJDengge Jia
Dengge Jia
JTJun Tao
Jun Tao
TDTianbai Deng
Tianbai Deng
LLLei Li
Lei Li
YHYiyun Huang
Yiyun Huang
MZMingxing Zhu
Mingxing Zhu
The reliable and controllable operation of the ITER machine relies on a compatible and stable power grid. The ITER Pulsed Power Electrical Network (PPEN) already has employed the Static Var Compensator (SVC), but issues, such as poor dynamic characteristics, insufficient capacity, and lack of means to cope with active power shock are still existed. To meet the updated needs of ITER's future operation, this paper proposes the Modular Multilevel Converter (MMC) combined with a supercapacitor (SC) energy storage scheme (E-STATCOM) to realize active and reactive power compensation. The Energy Management Mechanism (EMM) is detailed for the operation of the entire system. Furthermore, a cooperative control method based on an improved second-order filter is presented to achieve coordination with the existing SVC system, and the control decoupling are explored in the frequency domain. The detailed models are built in MATLAB/Simulink and demonstrate that the recommended scheme can effectively and stably achieve the power compensation objective. The paper provides reference design for the upgrade of ITER machine, as well as the power compensation solution for the load with large capacity, high uncertainty and significant impulse characteristics.

1 September 2019 in Energies
Verified
Journal Article
Open access
PDF file
MZMaosong Zhang
Maosong Zhang
YCYing Cui
Ying Cui
WQWang Qunjing
Wang Qunjing
JTJun Tao
Jun Tao
XWXiuqin Wang
Xiuqin Wang
GLGuoli Li
Guoli Li
This paper proposes an accurate mathematical model of three-level neutral-point-clamped (NPC) converters that can accurately represent the midpoint potential drift of the DC link with parameter perturbation. The mathematical relationships between the fluctuation in neutral-point voltage, the parametric perturbation, and the capacitance error are obtained as mathematical expressions in this model. The expressions can be used to quantitatively analyze the reason for the neutral-point voltage imbalance and balancing effect based on a zero-sequence voltage injection. The injected zero-sequence voltage, which can be used to balance the DC-side voltages with the combined action of active current, can be easily obtained from the proposed model. A balancing control under four-quadrant operation modes is proposed by considering the active current to verify the effectiveness of this model. Both the simulation and experiment results validate the excellent performance of the proposed model compared to the conventional model.

30 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
QZQianlong Zhu
Qianlong Zhu
JTJun Tao
Jun Tao
TDTianbai Deng
Tianbai Deng
MZMingxing Zhu
Mingxing Zhu
To enhance the stable performance of wind farm (WF) equivalent models in uncertain operating scenarios, a model-data-driven equivalent modeling method for doubly-fed induction generator (DFIG)-based WFs is proposed. Firstly, the aggregation-based WF equivalent models and the equivalent methods for aggregated parameters are analyzed and compared. Two mechanism models are selected from the perspective of practicality and complementarity of simulation accuracy. Secondly, the simulation parameters are set through two sampling methods to construct a training database. Next, the whole fault process is divided into five phases, and the weight coefficient optimization model is established according to the data-driven idea to achieve the adaptive configuration of the weight. Finally, the electromechanical transient simulations of the power systems with a DFIG-based WF is carried out by using the MATLAB/Simulink platform. Compared with the detailed WF model, the simulation time of the WF equivalent proposed in this paper can be significantly reduced by about 87%, and simulation results show that the proposed method can effectively improve the adaptability of the WF equivalent model in different wind scenarios and voltage dips.

23 November 2020 in Journal of Fusion Energy
Verified
Journal Article
Closed access
PDF file
DJDengge Jia
Dengge Jia
JTJun Tao
Jun Tao
RFRenjing Fan
Renjing Fan
JLJing Lu
Jing Lu

3 October 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HWHang Wang
Hang Wang
Lei MaoLei Mao
Lei Mao
YLYongbin Liu
Yongbin Liu
JTJun Tao
Jun Tao
ZHZhiyong Hu
Zhiyong Hu
YZYuanyuan Zhou
Yuanyuan Zhou
The performance inconsistency of lithium-ion battery packs is one of the key factors that lead to their accelerated lifespan degradation and reduced reliability. Hence, it is of great significance to accurately detect the consistency of cell parameters within the pack without destructive testing. The working current of the cell is the most direct and effective parameter to characterize the consistency of its module. However, cell level current is not monitored in commercial battery packs due to the limitations of current sensors. Therefore, this work proposes an inversion method using in situ magnetic field imaging for detecting unbalanced current induced by performance inconsistency of the pack. Through elucidating the superposition property of current-induced magnetic field between cells, a current inversion model for the battery pack is constructed, with the model principle and solution method given. Battery packs with different configuration structures are designed, simulated, and measured. The results show that this method can reduce the interference of susceptibility-induced magnetic field and achieve milliampere-level current calculated accuracy. This provides a new way to quickly and accurately evaluate the performance consistency of battery packs, and provides a technical guarantee for battery pack service performance testing and maintenance.