The reliable and controllable operation of the ITER machine relies on a compatible and stable power grid. The ITER Pulsed Power Electrical Network (PPEN) already has employed the Static Var Compensator (SVC), but issues, such as poor dynamic characteristics, insufficient capacity, and lack of means to cope with active power shock are still existed. To meet the updated needs of ITER's future operation, this paper proposes the Modular Multilevel Converter (MMC) combined with a supercapacitor (SC) energy storage scheme (E-STATCOM) to realize active and reactive power compensation. The Energy Management Mechanism (EMM) is detailed for the operation of the entire system. Furthermore, a cooperative control method based on an improved second-order filter is presented to achieve coordination with the existing SVC system, and the control decoupling are explored in the frequency domain. The detailed models are built in MATLAB/Simulink and demonstrate that the recommended scheme can effectively and stably achieve the power compensation objective. The paper provides reference design for the upgrade of ITER machine, as well as the power compensation solution for the load with large capacity, high uncertainty and significant impulse characteristics.
To enhance the stable performance of wind farm (WF) equivalent models in uncertain operating scenarios, a model-data-driven equivalent modeling method for doubly-fed induction generator (DFIG)-based WFs is proposed. Firstly, the aggregation-based WF equivalent models and the equivalent methods for aggregated parameters are analyzed and compared. Two mechanism models are selected from the perspective of practicality and complementarity of simulation accuracy. Secondly, the simulation parameters are set through two sampling methods to construct a training database. Next, the whole fault process is divided into five phases, and the weight coefficient optimization model is established according to the data-driven idea to achieve the adaptive configuration of the weight. Finally, the electromechanical transient simulations of the power systems with a DFIG-based WF is carried out by using the MATLAB/Simulink platform. Compared with the detailed WF model, the simulation time of the WF equivalent proposed in this paper can be significantly reduced by about 87%, and simulation results show that the proposed method can effectively improve the adaptability of the WF equivalent model in different wind scenarios and voltage dips.
The hybrid active power filter (HAPF) can effectively suppress the 75–125 Hz low-frequency harmonic current generated by the EAST poloidal field power supply. However, the low-frequency harmonic current suppression performance of HAPF is greatly affected by its control parameters when the circuit parameters are determined. In this paper, the state–space equation of the HAPF system is established, and the relationship between the eigenvalues of the state–space matrix and the HAPF control parameters is analyzed using the Lyapunov method. Based on the variation law of the eigenvalues, by optimizing the control parameters of the HAPF system, the low-frequency harmonic current suppression performance of HAPF is improved by 41.9%.
1 November 2026 in IEEE Transactions on Plasma Science