The constant growth of the population with mobility impairments has led to the development of several gait assistance devices. Among these, smart walkers have emerged to provide physical and cognitive interactions during rehabilitation and assistance therapies, by means of robotic and electronic technologies. In this sense, this paper presents the development and implementation of a human–robot–environment interface on a robotic platform that emulates a smart walker, the AGoRA Walker. The interface includes modules such as a navigation system, a human detection system, a safety rules system, a user interaction system, a social interaction system and a set of autonomous and shared control strategies. The interface was validated through several tests on healthy volunteers with no gait impairments. The platform performance and usability was assessed, finding natural and intuitive interaction over the implemented control strategies.
Smart walkers are commonly used as potential gait assistance devices, to provide physical and cognitive assistance within rehabilitation and clinical scenarios. To understand such rehabilitation processes, several biomechanical studies have been conducted to assess human gait with passive and active walkers. Several sessions were conducted with 11 healthy volunteers to assess three interaction strategies based on passive, low and high mechanical stiffness values on the AGoRA Smart Walker. The trials were carried out in a motion analysis laboratory. Kinematic data were also collected from the smart walker sensory interface. The interaction force between users and the device was recorded. The force required under passive and low stiffness modes was and smaller than the high stiffness mode, respectively. An increase of for the hip range of motion, as well as the highest trunk’s inclination, were obtained under the resistive mode, suggesting a compensating motion to exert a higher impulse force on the device. Kinematic and physical interaction data suggested that the high stiffness mode significantly affected the users’ gait pattern. Results suggested that users compensated their kinematics, tilting their trunk and lower limbs to exert higher impulse forces on the device.
Alterations to the human locomotor system, commonly result in problems related to balance and gait stability. To address such gait dysfunctions, several mobility aids have been developed. Devices, such as Smart Walkers (SWs), in conjunction with Human-Robot Interaction (HRI) interfaces, are typically implemented. However, common HRI interfaces are not able to provide safe assistance, at the same time as, proper environment interaction and natural user interaction. In this paper is presented the implementation of a safety robust and novel HRI interface on a SW, that provides secure human-walker interaction, as well as, environment and user interaction systems. To this end, a navigation system, a people detection system, a gait cadence estimator, a user's intention detection system and several control strategies were implemented. Additionally, a preliminary validation was conducted with a healthy user.
14 March 2023 in IEEE Robotics and Automation Letters
In recent years, advances in robotics and the constant growth of gait-related pathologies led to the development of different assistive devices. Smart walkers provide natural and intuitive strategies for gait assistance, such as path-following and guidance. Although these functionalities usually employ shared control approaches, the users' level of participation has yet to be assessed. This work presents the implementation of three modulation strategies for assisted navigation tasks. A path-following algorithm and a set of admittance-based controllers modulate the control authority between the user and the device. A group of 20 healthy subjects formed the validation group. Results showed a kinematic estimation error of 0.13 m for the strategy that shared the control authority with the user. Statistical tests found significant differences regarding the naturalness of the proposed approach (p-value of 0.00587).