Anselmo Frizera Neto

Dr. Anselmo Frizera Neto

Federal University of Espírito Santo
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2012 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
MMMaria M. Martins
Maria M. Martins
Cristina SantosCristina Santos
Cristina Santos
ANAnselmo Frizera Neto
Anselmo Frizera Neto
RCRamón Ceres
Ramón Ceres

18 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Arnaldo Leal-JuniorArnaldo Leal-Junior
Arnaldo Leal-Junior
Camilo Arturo Rodríguez DíazCamilo Arturo Rodríguez Díaz
Camilo Arturo Rodríguez Díaz
LALeticia Avellar
Leticia Avellar
Maria Jose PontesMaria Jose Pontes
Maria Jose Pontes
Carlos MarquesCarlos Marques
Carlos Marques
ANAnselmo Frizera Neto
Anselmo Frizera Neto
Advances in medicine and improvements in life quality has led to an increase in the life expectancy of the general population. An ageing world population have placed demands on the use of assistive technology and, in particular, towards novel healthcare devices and sensors. Besides the electromagnetic field immunity, polymer optical fiber (POF) sensors have additional advantages due to their material features such as high flexibility, lower Young’s modulus (enabling high sensitivity for mechanical parameters), higher elastic limits, and impact resistance. Such advantages are well-aligned with the instrumentation requirements of many healthcare devices and in movement analysis. Aiming at these advantages, this review paper presents the state-of-the-art developments of POF sensors for healthcare applications. A plethora of healthcare applications are discussed, which include movement analysis, physiological parameters monitoring, instrumented insoles, as well as instrumentation of healthcare robotic devices such as exoskeletons, smart walkers, actuators, prostheses, and orthosis. This review paper shows the feasibility of using POF sensors in healthcare applications and, due to the aforementioned advantages, it is possible to envisage a further widespread use of such sensors in this research field in the next few years.

17 August 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Arnaldo Leal-JuniorArnaldo Leal-Junior
Arnaldo Leal-Junior
LALeticia Avellar
Leticia Avellar
ANAnselmo Frizera Neto
Anselmo Frizera Neto
Carlos MarquesCarlos Marques
Carlos Marques
This paper presents the development and application of a multiparameter, quasi-distributed smart textile based on embedded highly stretchable polymer optical fiber (POF) sensors. The POF is fabricated using the light polymerization spinning process, resulting a highly stretchable optical fiber, so-called LPS-POF, with Young’s modulus and elastic limits of 15 MPa and 17%, respectively. The differential scanning calorimetry shows a thermal stability of the LPS-POF in temperature range of 13–40 °C. The developed sensors are based on the optical power variation, which results in a fully portable and low-cost technique. In order to obtain a multiplexed sensor system, a technique based on flexible light emitting diodes (LEDs) on–off keying modulation is applied, where each LED represents the response of one sensor. The smart textile comprises of LPS-POF and three flexible LEDs embedded in neoprene textile fabric. The performance of the system is evaluated for temperature, transverse force and angular displacement detection at different planes. The sensors presented high linearity (mean determination coefficient of 0.99) and high repeatability (inter-measurement deviations below 5%). The sensor is also applied in activity detection, where the principal component analysis (PCA) was applied in the sensors responses and, in conjunction with clustering techniques such as k-means, indicate the possibility of detecting basic activities such as walking, sitting on a chair and squatting.

1 January 2019 in Optics & Laser Technology
Verified
Journal Article
Closed access
Arnaldo Leal-JuniorArnaldo Leal-Junior
Arnaldo Leal-Junior
Camilo Arturo Rodríguez DíazCamilo Arturo Rodríguez Díaz
Camilo Arturo Rodríguez Díaz
Catia LeitaoCatia Leitao
Catia Leitao
Maria Jose PontesMaria Jose Pontes
Maria Jose Pontes
Carlos MarquesCarlos Marques
Carlos Marques
ANAnselmo Frizera Neto
Anselmo Frizera Neto

1 November 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Camilo Arturo Rodríguez DíazCamilo Arturo Rodríguez Díaz
Camilo Arturo Rodríguez Díaz
Arnaldo Leal-JuniorArnaldo Leal-Junior
Arnaldo Leal-Junior
PAPaulo Andre
Paulo Andre
Paulo AntunesPaulo Antunes
Paulo Antunes
Maria Jose PontesMaria Jose Pontes
Maria Jose Pontes
MRMoises R. N. Ribeiro
Moises R. N. Ribeiro
This paper proposes a fiber optic liquid level sensor system based on a silica fiber Bragg grating embedded into an epoxy resin diaphragm coupled to a temperature reference sensor, used to compensate the temperature cross-sensitivity for improving the liquid level measurement accuracy. The proposed system was tested in an industrial water tank with heating and recirculation. The results demonstrated a temperature cross-sensitivity reduction, enhancing the liquid level measurement thermal stability by a factor of nine, when compared with some single head sensor configurations reported in literature. Our system presents high linearity ( $R>0.999$ ), superior sensitivity (2.8 pm/mm), and much lower temperature related error (1.04 mm/°C), when compared with the other diaphragm-based sensors recently reported in the literature.

10 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
LVLaura Susana Vargas Valencia
Laura Susana Vargas Valencia
AEArlindo Elias
Arlindo Elias
EREduardo Rocon
Eduardo Rocon
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
ANAnselmo Frizera Neto
Anselmo Frizera Neto
This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.