Ivan Vujaklija

Prof. Ivan Vujaklija

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2017 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
IVIvan Vujaklija
Ivan Vujaklija
Massimo SartoriMassimo Sartori
Massimo Sartori
TKTamás Kapelner
Tamás Kapelner
FNFrancesco Negro
Francesco Negro
OAOskar C. Aszmann
Oskar C. Aszmann

31 May 2021 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
DFDario Farina
Dario Farina
IVIvan Vujaklija
Ivan Vujaklija
RBRickard Brånemark
Rickard Brånemark
ABAnthony M.J. Bull
Anthony M.J. Bull
HDHans Dietl
Hans Dietl
OAOskar C. Aszmann
Oskar C. Aszmann

26 August 2013 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
NJNing Jiang
Ning Jiang
HRHubertus Rehbaum
Hubertus Rehbaum
IVIvan Vujaklija
Ivan Vujaklija
BGBernhard Graimann
Bernhard Graimann
DFDario Farina
Dario Farina
We propose an approach for online simultaneous and proportional myoelectric control of two degrees-of-freedom (DoF) of the wrist, using surface electromyographic signals. The method is based on the nonnegative matrix factorization (NMF) of the wrist muscle activation to extract low-dimensional control signals translated by the user into kinematic variables. This procedure does not need a training set of signals for which the kinematics is known (labeled dataset) and is thus unsupervised (although it requires an initial calibration without labeled signals). The estimated control signals using NMF are used to directly control two DoFs of wrist. The method was tested on seven subjects with upper limb deficiency and on seven able-bodied subjects. The subjects performed online control of a virtual object with two DoFs to achieve goal-oriented tasks. The performance of the two subject groups, measured as the task completion rate, task completion time, and execution efficiency, was not statistically different. The approach was compared, and demonstrated to be superior to the online control by the industrial state-of-the-art approach. These results show that this new approach, which has several advantages over the previous myoelectric prosthetic control systems, has the potential of providing intuitive and dexterous control of artificial limbs for amputees.

25 October 2013 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
NJNing Jiang
Ning Jiang
IVIvan Vujaklija
Ivan Vujaklija
HRHubertus Rehbaum
Hubertus Rehbaum
BGBernhard Graimann
Bernhard Graimann
DFDario Farina
Dario Farina
In this paper, we present a systematic analysis of the relationship between the accuracy of the mapping between EMG and hand kinematics and the control performance in goal-oriented tasks of three simultaneous and proportional myoelectric control algorithms: nonnegative matrix factorization (NMF), linear regression (LR), and artificial neural networks (ANN). The purpose was to investigate the impact of the precision of the kinematics estimation by a myoelectric controller for accurately complete goal-directed tasks. Nine naïve subjects performed a series of goal-directed myoelectric control tasks using the three algorithms, and their online performance was characterized by 6 indexes. The results showed that, although the three algorithms' mapping accuracies were significantly different, their online performance was similar. Moreover, for LR and ANN, the offline performance was not correlated to any of the online performance indexes, and only a weak correlation was found with three of them for NMF . We conclude that for reliable simultaneous and proportional myoelectric control, it is not necessary to achieve high accuracy in the mapping between EMG and kinematics. Rather, good online myoelectric control is achieved by the continuous interaction and adaptation of the user with the myoelectric controller through feedback (visual in the current study). Control signals generated by EMG with rather poor association with kinematic variables can still be fully exploited by the user for precise control. This conclusion explains the possibility of accurate simultaneous and proportional control over multiple degrees of freedom when using unsupervised algorithms, such as NMF.

1 July 2016 in Orthopedic Research and Reviews
Verified
Journal Article
Open access
PDF file
IVIvan Vujaklija
Ivan Vujaklija
DFDario Farina
Dario Farina
OAOskar C. Aszmann
Oskar C. Aszmann
Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb functionality. This article is aimed at reviewing the latest state of the upper limb prosthetic market, offering insights on the accompanying technologies and techniques. We also examine the capabilities and features of some of academia’s flagship solutions and methods.

31 March 2015 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MIMark Ison
Mark Ison
IVIvan Vujaklija
Ivan Vujaklija
BWBryan Whitsell
Bryan Whitsell
DFDario Farina
Dario Farina
PAPanagiotis Artemiadis
Panagiotis Artemiadis
Myoelectric control offers a direct interface between human intent and various robotic applications through recorded muscle activity. Traditional control schemes realize this interface through direct mapping or pattern recognition techniques. The former approach provides reliable control at the expense of functionality, while the latter increases functionality at the expense of long-term reliability. An alternative approach, using concepts of motor learning, provides session-independent simultaneous control, but previously relied on consistent electrode placement over biomechanically independent muscles. This paper extends the functionality and practicality of the motor learning-based approach, using high-density electrode grids and muscle synergy-inspired decomposition to generate control inputs with reduced constraints on electrode placement. The method is demonstrated via real-time simultaneous and proportional control of a 4-DoF myoelectric interface over multiple days. Subjects showed learning trends consistent with typical motor skill learning without requiring any retraining or recalibration between sessions. Moreover, they adjusted to physical constraints of a robot arm after learning the control in a constraint-free virtual interface, demonstrating robust control as they performed precision tasks. The results demonstrate the efficacy of the proposed man-machine interface as a viable alternative to conventional control schemes for myoelectric interfaces designed for long-term use.