ILKNUR BABAHAN

Dr. ILKNUR BABAHAN


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2018 in Applied Organometallic Chemistry
Verified
Journal Article
Closed access
PDF file
AEAnthony Ekennia
Anthony Ekennia
AOAderoju A. Osowole
Aderoju A. Osowole
DODamian Onwudiwe
Damian Onwudiwe
IBILKNUR BABAHAN
ILKNUR BABAHAN
CICollins Ibeji
Collins Ibeji
OUOguejiofo Ujam
Oguejiofo Ujam

1 April 2015 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
IBILKNUR BABAHAN
ILKNUR BABAHAN
SESafiye Emirdağ-Öztürk
Safiye Emirdağ-Öztürk
EPEsin Poyrazoğlu-Çoban
Esin Poyrazoğlu-Çoban

1 March 2014 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
IBILKNUR BABAHAN
ILKNUR BABAHAN
FEFatih Eyduran
Fatih Eyduran
ECEsin Poyrazoglu Coban
Esin Poyrazoglu Coban
NONil Orhan
Nil Orhan
DKDidem Kazar
Didem Kazar
HBHalil Biyik
Halil Biyik

22 March 2020 in Applied Organometallic Chemistry
Verified
Journal Article
Closed access
PDF file
IBILKNUR BABAHAN
ILKNUR BABAHAN
AÖAli Özmen
Ali Özmen
MAMehran Aksel
Mehran Aksel
MBMehmet Dincer Bilgin
Mehmet Dincer Bilgin
RGRukiye Gumusada
Rukiye Gumusada
FEFatih Eyduran
Fatih Eyduran

24 February 2016 in Sensors
Verified
Journal Article
Open access
PDF file
BBBelygona Barare
Belygona Barare
IBILKNUR BABAHAN
ILKNUR BABAHAN
YHYousef Hijji
Yousef Hijji
EBEnock Bonyi
Enock Bonyi
STSolomon Tadesse
Solomon Tadesse
KAKadir Aslan
Kadir Aslan
The application of IR 786 perchlorate (IR-786) as a selective optical sensor for cyanide anion in both organic solution (acetonitrile (MeCN), 100%) and solvent-free solid surfaces was demonstrated. In MeCN, IR-786 was selective to two anions in the following order: CN− > OH−. A significant change in the characteristic dark green color of IR-786 in MeCN to yellow was observed as a result of nucleophilic addition of CN− to the fluorophore, i.e., formation of IR 786-(CN), which was also verified by a blue shift in the 775 nm absorbance peak to 430 nm. A distinct green fluorescence emission from the IR-786-(CN) in MeCN was also observed, which demonstrated the selectivity of IR-786 towards CN− in MeCN. Fluorescence emission studies of IR-786 showed that the lower detection limit and the sensitivity of IR-786 for CN− in MeCN was 0.5 μM and 0.5 to 8 μM, respectively. The potential use of IR-786 as a solvent-free solid state sensor for the selective sensing and monitoring of CN− in the environment was also demonstrated. On solvent-free solid state surfaces, the sensitivity of the IR-786 to CN− in water samples was in the range of 50–300 μM with minimal interference by OH−.

1 April 2014 in Bioorganic Chemistry
Verified
Journal Article
Closed access
SESafiye Emirdağ-Öztürk
Safiye Emirdağ-Öztürk
IBILKNUR BABAHAN
ILKNUR BABAHAN
AÖAli Özmen
Ali Özmen