Maarten Heusinkveld

Maarten Heusinkveld

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2015 in Journal Of Hypertension
Verified
Journal Article
Closed access
BSBart Spronck
Bart Spronck
MHMaarten Heusinkveld
Maarten Heusinkveld
FVFloris H. Vanmolkot
Floris H. Vanmolkot
JRJos op 't Roodt
Jos op 't Roodt
EHEvelien Hermeling
Evelien Hermeling
KRKoen D. Reesink
Koen D. Reesink
Arterial stiffness measures such as pulse wave velocity (PWV) have a known dependence on actual blood pressure, requiring consideration in cardiovascular risk assessment and management. Given the impact of ageing on arterial wall structure, the pressure-dependence of PWV may vary with age. Using a noninvasive model-based approach, combining carotid artery echo-tracking and tonometry waveforms, we obtained pressure-area curves in 23 hypertensive patients at baseline and after 3 months of antihypertensive treatment. We predicted the follow-up PWV decrease using modelled baseline curves and follow-up pressures. In addition, on the basis of these curves, we estimated PWV values for two age groups (mean ages 41 and 64 years) at predefined hypertensive (160/90 mmHg) and normotensive (120/80 mmHg) pressure ranges. Follow-up measurements showed a near 1 m/s decrease in carotid PWV when compared with baseline, which fully agreed with our model-prediction given the roughly 10 mmHg decrease in diastolic pressure. The stiffness-blood pressure-age pattern was in close agreement with corresponding data from the 'Reference Values for Arterial Stiffness' study, linking the physical and empirical bases of our findings. Our study demonstrates that the innate pressure-dependence of arterial stiffness may have implications for the clinical use of arterial stiffness measurements, both in risk assessment and in treatment monitoring of individual patients. We propose a number of clinically feasible approaches to account for the blood pressure effect on PWV measurements.

1 August 2019 in Journal of Applied Physiology
Verified
Journal Article
Open access
PDF file
MHMaarten Heusinkveld
Maarten Heusinkveld
Tammo DelhaasTammo Delhaas
Tammo Delhaas
JLJoost Lumens
Joost Lumens
WHWouter Huberts
Wouter Huberts
BSBart Spronck
Bart Spronck
KRKoen Reesink
Koen Reesink
The augmentation index (AIx) is deemed to capture the deleterious effect on left ventricular (LV) work of increased wave reflection associated with stiffer arteries. However, its validity as a proxy for wave reflection magnitude has been questioned. We hypothesized that, in addition to increased wave reflection due to increased pulse wave velocity, LV myocardial shortening velocity influences AIx. Using a computational model of the circulation, we investigated the isolated and combined influences of myocardial shortening velocity vs,LV and arterial stiffness on AIx. Aortic blood pressure waveforms were characterized using AIx and the reflected wave pressure amplitude ([ ], obtained using wave separation analysis). Our reference simulation (normal vs,LV and arterial stiffness) was characterized by an AIx of 21%. A realistic reduction in vs,LV caused AIx to increase from 21 to 42%. An arterial stiffness increase, characterized by a relevant 1.0 m/s increase in carotid-femoral pulse wave velocity, caused AIx to increase from 21 to 41%. Combining the reduced vs,LV and increased arterial stiffness resulted in an AIx of 54%. In a multistep parametric analysis, both vs,LV and arterial stiffness were about equal determinants of AIx, whereas [ ] was only determined by arterial stiffness. Furthermore, the relation between increased AIx and LV stroke work was only ≈50% explained by an increase in arterial stiffness, the other factor being vs,LV. The [ ], on the other hand, related less ambiguously to LV stroke work. We conclude that the AIx reflects both cardiac and vascular properties and should not be considered an exclusively vascular parameter. NEW & NOTEWORTHY We used a state-of-the-art computational model to mechanistically investigate the validity of the augmentation index (AIx) as a proxy for (changes in) wave reflection. In contrary to current belief, we found that LV contraction velocity influences AIx as much as increased arterial stiffness, and increased AIx does not necessarily relate to an increase in LV stroke work. Wave reflection magnitude derived from considering pressure, as well as flow, does qualify as a determinant of LV stroke work.

1 July 2017 in American Journal of Roentgenology
Verified
Journal Article
Closed access
MCMarie-Hélène Roy Cardinal
Marie-Hélène Roy Cardinal
MHMaarten Heusinkveld
Maarten Heusinkveld
ZQZhao Qin
Zhao Qin
RLRichard G. P. Lopata
Richard G. P. Lopata
CNCyrille Naim
Cyrille Naim
GCGuy Cloutier
Guy Cloutier
OBJECTIVE. Vulnerable and nonvulnerable carotid artery plaques have different tissue morphology and composition that may affect plaque biomechanics. The objective of this study is to evaluate plaque vulnerability with the use of ultrasound noninvasive vascular elastography (NIVE). MATERIALS AND METHODS. Thirty-one patients (mean [± SD] age, 69 ± 7 years) with stenosis of the internal carotid artery of 50% or greater were enrolled in this cross-sectional study. Elastography parameters quantifying axial strain, shear strain, and translation motion were used to characterize carotid artery plaques as nonvulnerable, neovascularized, and vulnerable. Maximum axial strain, cumulated axial strain, mean shear strain, cumulated shear strain, cumulated axial translation, and cumulated lateral translations were measured. Cumulated measurements were summed over a cardiac cycle. The ratio of cumulated axial strain to cumulated axial translation was also evaluated. The reference method used to characterize plaques was hi...

25 April 2013 in British Medical Bulletin
Verified
Journal Article
Open access
PDF file
MHMaarten Heusinkveld
Maarten Heusinkveld
AHAnniek Den Hamer
Anniek Den Hamer
WTWilleke A. Traa
Willeke A. Traa
POP. J. A. Oomen
P. J. A. Oomen
Nicola MaffulliNicola Maffulli
Nicola Maffulli
Several methods of transverse patellar fixation have been described. This study compares the clinical outcome and the occurrence of complications of various fixation methods. The databases PubMed, Web of Science, Science Direct, Google Scholar and Google were searched. A direct comparison between fixation techniques using mixed or non-metallic implants and metallic K-wire and tension band fixation shows no significant difference in clinical outcome between both groups. Additionally, studies reporting novel operation techniques show good clinical results. Studies describing the treatment of patients using non-metallic or mixed implants are fewer compared with those using metallic fixation. A large variety of clinical scoring systems were used for assessing the results of treatment, which makes direct comparison difficult. More data of fracture treatment using non-metallic or mixed implants is needed to achieve a more balanced comparison.

15 March 2015 in American Journal of Physiology-Heart and Circulatory Physiology
Verified
Journal Article
Closed access
PDF file
BSBart Spronck
Bart Spronck
MHMaarten Heusinkveld
Maarten Heusinkveld
WDWouter P. Donders
Wouter P. Donders
ALAnouk G. W. de Lepper
Anouk G. W. de Lepper
JRJos op 't Roodt
Jos op 't Roodt
KRKoen D. Reesink
Koen D. Reesink
Aging has a profound influence on arterial wall structure and function. We have previously reported the relationship among pulse wave velocity, age, and blood pressure in hypertensive subjects. In the present study, we aimed for a quantitative interpretation of the observed changes in wall behavior with age using a constitutive modeling approach. We implemented a model of arterial wall biomechanics and fitted this to the group-averaged pressure-area (P-A) relationship of the “young” subgroup of our study population. Using this model as our take-off point, we assessed which parameters had to be changed to let the model describe the “old” subgroup’s P-A relationship. We allowed elastin stiffness and collagen recruitment parameters to vary and adjusted residual stress parameters according to published age-related changes. We required wall stress to be homogeneously distributed over the arterial wall and assumed wall stress normalization with age by keeping average “old” wall stress at the “young” level. Additionally, we required axial force to remain constant over the cardiac cycle. Our simulations showed an age-related shift in pressure-load bearing from elastin to collagen, caused by a decrease in elastin stiffness and a considerable increase in collagen recruitment. Correspondingly, simulated diameter and wall thickness increased by about 20 and 17%, respectively. The latter compared well with a measured thickness increase of 21%. We conclude that the physiologically realistic changes in constitutive properties we found under physiological constraints with respect to wall stress could well explain the influence of aging in the stiffness-pressure-age pattern observed.

31 July 2013 in British Medical Bulletin
Verified
Journal Article
Open access
PDF file
WTWilleke A. Traa
Willeke A. Traa
POP. J. A. Oomen
P. J. A. Oomen
AHAnniek Den Hamer
Anniek Den Hamer
MHMaarten Heusinkveld
Maarten Heusinkveld
Nicola MaffulliNicola Maffulli
Nicola Maffulli
Several methods of transverse patellar and olecranon fixation have been described. This article compares biomechanical studies of various fixation methods using a newly developed scoring method. The databases PubMed, Web of Science, Science Direct, Google Scholar and Google were searched for relevant studies. Fixation hardware failure remains a problem. Various materials and fixation techniques have been tested to provide an improved fixation of transverse olecranon and patellar fractures. The difference in biomechanical testing setup between the studies makes it hard to compare different fixation techniques. The newly developed grading method was proved to be unbiased and reliable; however, extra specifications need to be added at some criteria when adopting the scoring method. Non-metallic constructs may provide an improvement to the currently used metallic tension band wiring technique; however, clinical research is required.