Seunghyun Kim

Dr. Seunghyun Kim

Department of Electrical and Computer Engineering, School of Engineering, Baylor University, Waco, TX 76798, USA
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
MSMarzhan Sypabekova
Marzhan Sypabekova
AHAidan Hagemann
Aidan Hagemann
DRDonggee Rho
Donggee Rho
Seunghyun KimSeunghyun Kim
Seunghyun Kim
Surface functionalization and bioreceptor immobilization are critical processes in developing a highly sensitive and selective biosensor. The silanization process with 3-aminopropyltriethoxysilane (APTES) on oxide surfaces is frequently used for surface functionalization because of beneficial characteristics such as its bifunctional nature and low cost. Optimizing the deposition process of the APTES layer to obtain a monolayer is crucial to having a stable surface and effectively immobilizing the bioreceptors, which leads to the improved repeatability and sensitivity of the biosensor. This review provides an overview of APTES deposition methods, categorized into the solution-phase and vapor-phase, and a comprehensive summary and guide for creating stable APTES monolayers on oxide surfaces for biosensing applications. A brief explanation of APTES is introduced, and the APTES deposition methods with their pre/post-treatments and characterization results are discussed. Lastly, APTES deposition methods on nanoparticles used for biosensors are briefly described.

31 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JLJessanne Lichtenberg
Jessanne Lichtenberg
YLYue Ling
Yue Ling
Seunghyun KimSeunghyun Kim
Seunghyun Kim
Non-specific adsorption (NSA) is a persistent problem that negatively affects biosensors, decreasing sensitivity, specificity, and reproducibility. Passive and active removal methods exist to remedy this issue, by coating the surface or generating surface forces to shear away weakly adhered biomolecules, respectively. However, many surface coatings are not compatible or effective for sensing, and thus active removal methods have been developed to combat this phenomenon. This review aims to provide an overview of methods of NSA reduction in biosensing, focusing on the shift from passive methods to active methods in the past decade. Attention is focused on protein NSA, due to their common use in biosensing for biomarker diagnostics. To our knowledge, this is the first review to comprehensively discuss active NSA removal methods. Lastly, the challenges and future perspectives of NSA reduction in biosensing are discussed.

19 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DRDonggee Rho
Donggee Rho
CBCaitlyn Breaux
Caitlyn Breaux
Seunghyun KimSeunghyun Kim
Seunghyun Kim
The demand for biosensor technology has grown drastically over the last few decades, mainly in disease diagnosis, drug development, and environmental health and safety. Optical resonator-based biosensors have been widely exploited to achieve highly sensitive, rapid, and label-free detection of biological analytes. The advancements in microfluidic and micro/nanofabrication technologies allow them to be miniaturized and simultaneously detect various analytes in a small sample volume. By virtue of these advantages and advancements, the optical resonator-based biosensor is considered a promising platform not only for general medical diagnostics but also for point-of-care applications. This review aims to provide an overview of recent progresses in label-free optical resonator-based biosensors published mostly over the last 5 years. We categorized them into Fabry-Perot interferometer-based and whispering gallery mode-based biosensors. The principles behind each biosensor are concisely introduced, and recent progresses in configurations, materials, test setup, and light confinement methods are described. Finally, the current challenges and future research topics of the optical resonator-based biosensor are discussed.

15 May 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
SSSavanah Smith
Savanah Smith
MSMarzhan Sypabekova
Marzhan Sypabekova
Seunghyun KimSeunghyun Kim
Seunghyun Kim
The demand for easy-to-use, affordable, accessible, and reliable technology is increasing in biological, chemical, and medical research. Microfluidic devices have the potential to meet these standards by offering cost-effective, highly sensitive, and highly specific diagnostic tests with rapid performance and minimal sample volumes. Traditional microfluidic device fabrication methods, such as photolithography and soft lithography, are time-consuming and require specialized equipment and expertise, making them costly and less accessible to researchers and clinicians and limiting the applicability and potential of microfluidic devices. To address this, researchers have turned to using new low-cost materials, such as double-sided tape for microfluidic device fabrication, which offers simple and low-cost processes. The innovation of low-cost and easy-to-make microfluidic devices improves the potential for more devices to be transitioned from laboratories to commercialized products found in stores, offices, and homes. This review serves as a comprehensive summary of the growing interest in and use of double-sided tape-based microfluidic devices in the last 20 years. It discusses the advantages of using double-sided tape, the fabrication techniques used to create and bond microfluidic devices, and the limitations of this approach in certain applications.

13 January 2003 in Optics Express
Verified
Journal Article
Open access
PDF file
DCDiana M. Chambers
Diana M. Chambers
Gregory P NordinGregory P Nordin
Gregory P Nordin
Seunghyun KimSeunghyun Kim
Seunghyun Kim
We have demonstrated a high-efficiency grating (>80%) using a three-layer Stratified Volume Diffractive Optical Element (SVDOE). Its angular sensitivity was measured optically and shown to agree extremely well with simulations performed using rigorous coupled wave analysis (RCWA). Further simulations predict an increase in efficiency as the number of layers is increased. An SVDOE consists of binary grating layers interleaved with homogeneous layers. The binary grating layers are shifted laterally relative to each other to emulate a volume holographic grating with slanted fringes. Creating the slanted fringe structure permits the preferred incidence angle of the SVDOE to be rotated to any arbitrary position. Achieving the relative offset between grating layers is the most challenging fabrication step and required the development of a high-precision alignment technique that was implemented on a contact mask aligner. The approach is based on monitoring the diffraction signal of a beam that is transmitted through gratings on the substrate and those on the mask as they are translated with respect to one another during pre-exposure alignment. The homogeneous layers are fabricated using a polymer material, SU-8, that is spin-coated and then planarized during its curing process.

24 December 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
DRDonggee Rho
Donggee Rho
Seunghyun KimSeunghyun Kim
Seunghyun Kim
An optical cavity-based biosensor (OCB) has been developed for point-of-care (POC) applications. This label-free biosensor employs low-cost components and simple fabrication processes to lower the overall cost while achieving high sensitivity using a differential detection method. To experimentally demonstrate its limit of detection (LOD), we conducted biosensing experiments with streptavidin and C-reactive protein (CRP). The optical cavity structure was optimized further for better sensitivity and easier fluid control. We utilized the polymer swelling property to fine-tune the optical cavity width, which significantly improved the success rate to produce measurable samples. Four different concentrations of streptavidin were tested in triplicate, and the LOD of the OCB was determined to be 1.35 nM. The OCB also successfully detected three different concentrations of human CRP using biotinylated CRP antibody. The LOD for CRP detection was 377 pM. All measurements were done using a small sample volume of 15 µL within 30 min. By reducing the sensing area, improving the functionalization and passivation processes, and increasing the sample volume, the LOD of the OCB are estimated to be reduced further to the femto-molar range. Overall, the demonstrated capability of the OCB in the present work shows great potential to be used as a promising POC biosensor.