A high étendue static Fourier transform spectral imager has been developed for airborne use. This imaging spectrometer, based on a Michelson interferometer with rooftop mirrors, is compact and robust and benefits from a high collection efficiency. Experimental airborne images were acquired in the visible domain. The processing chain to convert raw images to hyperspectral data is described, and airborne spectral images are presented. These experimental results show that the spectral resolution is close to the one expected, but also that the signal to noise ratio is limited by various phenomena (jitter, elevation fluctuations, and one parasitic image). We discuss the origin of those limitations and suggest solutions to circumvent them.
Quantification of gaseous emission fluxes from volcanoes can yield valuable insights on processes occurring in the Earth’s interior as part of hazard monitoring. It is also an important task in the framework of climate change, in order to refine estimates of natural emissions. Passive open-path UltraViolet (UV) scattered observation by UV camera allows the imaging of volcanic plumes and evaluation of sulfur dioxide (SO2) fluxes at high temporal resolution during daytime. Another technique of imaging is now available in the InfraRed (IR) spectral domain. Infrared hyperspectral imagers have the potential to overcome the boundary of daytime sampling of the UV, providing measurements also during the night and giving access simultaneously to additional relevant gas species. In this context the IMAGETNA campaign of measurements took place at Mt Etna (Italy) in June 2015. Three different IR imagers (commercial and under developments) were deployed, together with a Fourier Transform InfraRed spectrometer (FTIR) instrument, a UV camera, a Long Wavelength InfraRed (LWIR) camera and a radiometer. We present preliminary results obtained by the two IR cameras under development, and then the IR hyperspectral imager results, coming from full physics retrieval, are compared to those of the UV camera. The comparison points out an underestimation of the SO2 Slant Column Densities (SCD) of the UV camera by a factor of 3.6. The detailed study of the retrieved SO2 SCD highlights the promising application of IR imaging in volcanology for remotely volcanic plume gas measurements. It also provides a way to investigate uncertainties in the SO2 SCD imaging in the UV and the IR.
Uncooled and shutterless microbolometer cameras are good candidates for infrared imaging systems installed on small satellites or small unmanned aerial vehicles: they are light and passive since no cooling system or mechanical shutter is required and they can be operated at ambient temperatures. However, the radiometric compensation has to be carefully performed to make the system compatible with applications where the radiometric accuracy of the images is mandatory. In this paper, we study the impact of the camera environment to the radiometric accuracy of the images. We propose and test hardware and software solutions to improve this accuracy and the quality of the radiometric images. We show that the radiometric calibration of the camera with our model is valid over a long time period— about 3 years—using in-door experiments.
Imaging lateral shearing interferometers are good candidates for airborne or spaceborne Fourier- transform spectral imaging. For such applications, compactness is one key parameter. In this article, we compare the size of four mirror-based interferometers, the Michelson interferometer with roof-top (or corner-cube) mirrors, and the cyclic interferometers with two, three, and four mirrors, focusing more particularly on the last two designs. We give the expression of the translation they induce between the two exiting rays. We then show that the cyclic interferometer with three mirrors can be made quite compact. Nevertheless, the Michelson interferometer is the most compact solution, especially for highly diverging beams.
Imaging static Fourier transform spectrometry (isFTS) is used for pushbroom airborne or spaceborne hyperspectral remote sensing. In isFTS, a static two -wave interferometer imprints linear interference fringes over the image of the scene, so that the spectral information is multiplexed over several instantaneous images, and numerical reconstruction is needed to recover the full spectrum for each pixel. The image registration step is crucial since insufficient accuracy leads to artefacts on the images and the estimated spectra. In order to investigate these artifacts, we performed a theoretical study and designed a simulation program. We established that registration errors create crenellated spatial patterns, the magnitude of which depends on the radiance gradient of the scene, the amplitude of the registration error, and the wavelength. In the case of sinusoidal perturbations, which may correspond for instance to mechanical vibrations of the carrier, we established that spurious peaks appear on the spectrum, similarly to what happens in dynamic FTS, but with spatial patterns specific to static interferometers.