DIEGO SALES LERIDA

Dr. DIEGO SALES LERIDA

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
ABAlfonso José Bello
Alfonso José Bello
AAAlberto Sánchez Alzola
Alberto Sánchez Alzola
PMPedro Manuel Martínez-Jiménez
Pedro Manuel Martínez-Jiménez
Good air quality is essential for both human beings and the environment in general. The three most harmful air pollutants are nitrogen dioxide (NO2), ozone (O3) and particulate matter. Due to the high cost of monitoring stations, few examples of this type of infrastructure exist, and the use of low-cost sensors could help in air quality monitoring. The cost of metal-oxide sensors (MOS) is usually below EUR 10 and they maintain small dimensions, but their use in air quality monitoring is only valid through an exhaustive calibration process and subsequent precision analysis. We present an on-field calibration technique, based on the least squares method, to fit regression models for low-cost MOS sensors, one that has two main advantages: it can be easily applied by non-expert operators, and it can be used even with only a small amount of calibration data. In addition, the proposed method is adaptive, and the calibration can be refined as more data becomes available. We apply and evaluate the technique with a real dataset from a particular area in the south of Spain (Granada city). The evaluation results show that, despite the simplicity of the technique and the low quantity of data, the accuracy obtained with the low-cost MOS sensors is high enough to be used for air quality monitoring.

20 June 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
BTBlanca María Priego Torres
Blanca María Priego Torres
ALAntonio Leon-Jimenez
Antonio Leon-Jimenez
Cough is a frequent symptom in many common respiratory diseases and is considered a predictor of early exacerbation or even disease progression. Continuous cough monitoring offers valuable insights into treatment effectiveness, aiding healthcare providers in timely intervention to prevent exacerbations and hospitalizations. Objective cough monitoring methods have emerged as superior alternatives to subjective methods like questionnaires. In recent years, cough has been monitored using wearable devices equipped with microphones. However, the discrimination of cough sounds from background noise has been shown a particular challenge. This study aimed to demonstrate the effectiveness of single-axis acceleration signals combined with state-of-the-art deep learning (DL) algorithms to distinguish intentional coughing from sounds like speech, laugh, or throat noises. Various DL methods (recurrent, convolutional, and deep convolutional neural networks) combined with one- and two-dimensional time and time–frequency representations, such as the signal envelope, kurtogram, wavelet scalogram, mel, Bark, and the equivalent rectangular bandwidth spectrum (ERB) spectrograms, were employed to identify the most effective approach. The optimal strategy, which involved the SqueezeNet model in conjunction with wavelet scalograms, yielded an accuracy and precision of 92.21% and 95.59%, respectively. The proposed method demonstrated its potential for cough monitoring. Future research will focus on validating the system in spontaneous coughing of subjects with respiratory diseases under natural ambulatory conditions.

24 April 2019 in Energies
Verified
Journal Article
Open access
PDF file
JGJose-Maria Guerrero-Rodriguez
Jose-Maria Guerrero-Rodriguez
CSClemente Cobos Sanchez
Clemente Cobos Sanchez
Juan-José González-de-la-RosaJuan-José González-de-la-Rosa
Juan-José González-de-la-Rosa
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
The energy supply of office buildings and smart homes is a key issue in the global energy system. The growing use of microelectronics-based technology achieves new devices for a more comfortable life and wider use of electronic office equipment. On the one hand, these applications incorporate more and more sensitive electronic devices which are potentially affected by any external electrical transient. On the other hand, the existing electrical loads, which generally use electronic power systems (such as different types of battery chargers, ballasts, inverters, switching power supplies, etc.), generate different kinds of transients in their own electrical internal network. Moreover, improvements in the information of the state of the mains alternating current (AC) power line allows risk evaluation of any disturbance caused to permanently connected electronic equipment, such as computers, appliances, home security systems, phones, TVs, etc. For this reason, it is nowadays more important to introduce monitoring solutions into the electrical network to measure the level of power quality so that it can protect itself when necessary. This article describes a small and compact detector using a low-cost microcontroller and a very simple direct acquiring circuit. In addition; it analyzes different methods to implement various power quality (PQ) surveillance algorithms that can be implemented in this proposed minimum hardware platform. Hence; it is possible to achieve cheap and low-power monitoring devices that can become nodes of a wireless sensor network (WSN). The work shows that using a small computational effort; reasonable execution speed; and acceptable reliability; this solution can be used to detect a variety of large disturbance phenomena and spread the respective failure report through a 433 MHz or 2.4 GHz radio transmitter. Therefore, this work can easily be extended to the Internet of Things (IoT) paradigm. Simultaneously, a software application (PulsAC) has been developed to monitor the microcontroller’s real-time progress and detection capability. Moreover, this high-level code (C++ language), allows us to test and debug the different utilized algorithms that will be later run by the microcontroller unit. These tests have been performed with real signals introduced by a function generator and superimposed on the true AC sine wave

28 November 2025 in Smart Cities
Verified
Journal Article
Open access
PDF file
Patricia Camacho MagriñánPatricia Camacho Magriñán
Patricia Camacho Magriñán
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
ALAlejandro Lara-Dona
Alejandro Lara-Dona
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
Indoor air quality (IAQ) in residential settings is often dominated by high-concentration pollutant events from activities such as cooking and occupancy, which are overlooked by traditional 24 h average assessments. In this, we have designed and implemented a low-cost unit for remote IAQ monitoring. We deployed these units for high-resolution remote monitoring of CO2, particulate matter (PM), and volatile organic compounds (VOCs) in three different domestic environments: a kitchen, a living room, and a bedroom. The monitoring campaign confirmed that, while daily averages frequently remained below guideline limits, transient peaks (e.g., CO2 exceeding 2800 ppm in bedrooms and significant increases in PM during cooking) posed acute exposure risks. This dataset was used to train and evaluate machine learning models for 10 min ahead pollutant forecasting. Ensemble tree-based methods (Random Forest) and gradient boosting algorithms (XGBoost, LGBM, and CatBoost) were effective and robust. The predictability of the models correlated with room dynamics: performance improved under clear cyclical patterns (bedroom) and remained stable under stochastic events (kitchen). This work shows that integrating low-cost IoT sensing with machine learning enables proactive IAQ management, supporting health interventions driven by predictive risk rather than static averages.

18 March 2025 in Technologies
Verified
Journal Article
Open access
PDF file
Patricia Camacho MagriñánPatricia Camacho Magriñán
Patricia Camacho Magriñán
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
ALAntonio Leon-Jimenez
Antonio Leon-Jimenez
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
Chronic respiratory diseases (CRD), which include Chronic Obstructive Pulmonary Disease (COPD) and asthma, are significant global health issues, with air quality playing a vital role in exacerbating these conditions. This systematic review explores how monitoring indoor air quality (IAQ) can help manage and reduce respiratory exacerbations in CRD patients. A search of the Web of Science database, yielding 301 articles, was conducted following PRISMA guidelines. Of these, 60 met the inclusion criteria, and after screening, 21 articles were analyzed. The review identified substantial gaps in current research: the lack of standardization in IAQ monitoring; the need for considering geographic variability and for long-term longitudinal studies; and the importance of linking monitored air quality data with respiratory health indicators. It also stressed the importance of considering the heterogeneity of patients in the methodological study design, as well as the convenience of introducing recommendation systems to assess the true impact of corrective measures on indoor air quality in the homes of chronic respiratory patients. The integration of home-based IAQ monitoring with machine learning techniques to enhance our understanding of the relationship between IAQ and respiratory health is emerging as a key area for future research. Addressing all these challenges has the potential to mitigate the impact of CRD and improve the quality of life for patients.

4 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
Juan Grosso SicreJuan Grosso Sicre
Juan Grosso Sicre
PMPedro Manuel Martínez-Jiménez
Pedro Manuel Martínez-Jiménez
MQManuel Manzano Quiñones
Manuel Manzano Quiñones
The lack of safe drinking water is one of the main health problems in many regions of the world. In order to face it, Solar water disinfection (SODIS) proposes the use of transparent plastic containers, which are filled with contaminated water, and exposed to direct sunlight until enough UV radiation is received to inactivate the pathogens. However, a reliable method for determining the end of the disinfection process is needed. Although several approaches have been proposed in the literature for this purpose, they do not strictly accomplish two critical constraints that are essential in this type of project, namely, low cost and sustainability. In this paper, we propose an electronic device to determine when the lethal UV dose has been reached in SODIS containers, which accomplishes both constraints mentioned above: on the one hand, its manufacturing cost is around EUR 12, which is much lower than the price of other electronic solutions; on the other hand, the device is sufficiently autonomous to work for months with small low-cost disposable batteries, thereby avoiding the use of rechargeable batteries, which are considered hazardous waste at the end of their useful life. In our approach, we first analyze different low cost UV sensors in order to select the most accurate one by comparing their response with a reference pattern provided by a radiometer. Then, an electronic device is designed using this sensor, which measures the accumulated UV radiation and compares this value with the lethal UV dose to determine the end of the disinfection process. Finally, the device has been manufactured and tested in real conditions to analyze its accuracy, obtaining satisfactory results.