Alejandro Lara-Dona

Mr. Alejandro Lara-Dona

University of Cádiz
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
PMPilar Muñoz-Zara
Pilar Muñoz-Zara
ALAlejandro Lara-Dona
Alejandro Lara-Dona
ALAntonio Leon-Jimenez
Antonio Leon-Jimenez
Long-term oxygen therapy (LTOT) has become standard care for the treatment of patients with chronic obstructive pulmonary disease (COPD) and other severe hypoxemic lung diseases. The use of new portable O2 concentrators (POC) in LTOT is being expanded. However, the issue of oxygen titration is not always properly addressed, since POCs rely on proper use by patients. The robustness of algorithms and the limited reliability of current oximetry sensors are hindering the effectiveness of new approaches to closed-loop POCs based on the feedback of blood oxygen saturation. In this study, a novel intelligent portable oxygen concentrator (iPOC) is described. The presented iPOC is capable of adjusting the O2 flow automatically by real-time classifying the intensity of a patient’s physical activity (PA). It was designed with a group of patients with COPD and stable chronic respiratory failure. The technical pilot test showed a weighted accuracy of 91.1% in updating the O2 flow automatically according to medical prescriptions, and a general improvement in oxygenation compared to conventional POCs. In addition, the usability achieved was high, which indicated a significant degree of user satisfaction. This iPOC may have important benefits, including improved oxygenation, increased compliance with therapy recommendations, and the promotion of PA.

26 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
ALAlejandro Lara-Dona
Alejandro Lara-Dona
Sonia Torres SánchezSonia Torres Sánchez
Sonia Torres Sánchez
BTBlanca María Priego Torres
Blanca María Priego Torres
EBEsther Berrocoso
Esther Berrocoso
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
Strong evidence from studies on primates and rodents shows that changes in pupil diameter may reflect neural activity in the locus coeruleus (LC). Pupillometry is the only available non-invasive technique that could be used as a reliable and easily accessible real-time biomarker of changes in the in vivo activity of the LC. However, the application of pupillometry to preclinical research in rodents is not yet fully standardized. A lack of consensus on the technical specifications of some of the components used for image recording or positioning of the animal and cameras have been recorded in recent scientific literature. In this study, a novel pupillometry system to indirectly assess, in real-time, the function of the LC in anesthetized rodents is presented. The system comprises a deep learning SOLOv2 instance-based fast segmentation framework and a platform designed to place the experimental subject, the video cameras for data acquisition, and the light source. The performance of the proposed setup was assessed and compared to other baseline methods using a validation and an external test set. In the latter, the calculated intersection over the union was 0.93 and the mean absolute percentage error was 1.89% for the selected method. The Bland–Altman analysis depicted an excellent agreement. The results confirmed a high accuracy that makes the system suitable for real-time pupil size tracking, regardless of the pupil’s size, light intensity, or any features typical of the recording process in sedated mice. The framework could be used in any neurophysiological study with sedated or fixed-head animals.

28 November 2025 in Smart Cities
Verified
Journal Article
Open access
PDF file
Patricia Camacho MagriñánPatricia Camacho Magriñán
Patricia Camacho Magriñán
DLDIEGO SALES LERIDA
DIEGO SALES LERIDA
ALAlejandro Lara-Dona
Alejandro Lara-Dona
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
Indoor air quality (IAQ) in residential settings is often dominated by high-concentration pollutant events from activities such as cooking and occupancy, which are overlooked by traditional 24 h average assessments. In this, we have designed and implemented a low-cost unit for remote IAQ monitoring. We deployed these units for high-resolution remote monitoring of CO2, particulate matter (PM), and volatile organic compounds (VOCs) in three different domestic environments: a kitchen, a living room, and a bedroom. The monitoring campaign confirmed that, while daily averages frequently remained below guideline limits, transient peaks (e.g., CO2 exceeding 2800 ppm in bedrooms and significant increases in PM during cooking) posed acute exposure risks. This dataset was used to train and evaluate machine learning models for 10 min ahead pollutant forecasting. Ensemble tree-based methods (Random Forest) and gradient boosting algorithms (XGBoost, LGBM, and CatBoost) were effective and robust. The predictability of the models correlated with room dynamics: performance improved under clear cyclical patterns (bedroom) and remained stable under stochastic events (kitchen). This work shows that integrating low-cost IoT sensing with machine learning enables proactive IAQ management, supporting health interventions driven by predictive risk rather than static averages.

11 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
ALAlejandro Lara-Dona
Alejandro Lara-Dona
BTBlanca María Priego Torres
Blanca María Priego Torres
MGMaria Morales González
Maria Morales González
FMFrancisca Montoro-Ballesteros
Francisca Montoro-Ballesteros
ALAntonio Leon-Jimenez
Antonio Leon-Jimenez
The appropriate titration for the personalized oxygen needs of patients with chronic obstructive pulmonary disease (COPD) and severe hypoxemia is a determining factor in the success of long-term oxygen therapy. There are no standardized procedures to assist in determining the patient’s needs during the physical activities of daily life. Despite that effort tests are a wide broad approach, further research concerning the development of protocols to titrate O2 therapy is needed. The main objective of this study was to assess whether the level of oxygen titrated through the 6-minute walking test (6MWT) for patients with COPD and exertional hypoxemia is adequate to meet the patients’ demand during their activities of daily living. Physiological and subjective variables were estimated for a study population during two walking tests: a 6MWT and a 20-minute walking circuit (20MWC), designed ad-hoc to reproduce daily physical activities more truthfully. The results indicate that in a significant proportion of patients, the 6MWT might not accurately predict their oxygen needs at a domiciliary environment. Therefore, the titration of the portable O2 therapy could not be optimal in these cases, with the detrimental impact on the patient’s health (hyperoxia episodes), the autonomy of the oxygen device, and the decrease of time out of the home.

25 September 2019
Verified
Book Chapter
Closed access
PDF file
ALAlejandro Lara-Dona
Alejandro Lara-Dona
Daniel Sanchez-MorilloDaniel Sanchez-Morillo
Daniel Sanchez-Morillo
MPMaría Pérez-Morales
María Pérez-Morales
MGMiguel Angel Fernandez Granero
Miguel Angel Fernandez Granero
ALAntonio Leon-Jimenez
Antonio Leon-Jimenez

27 November 2020
Verified
Conference Paper
Closed access
ALAlejandro Lara-Dona
Alejandro Lara-Dona
SSSonia Torres Sánchez
Sonia Torres Sánchez
DSDaniel Sánchez-Morillo
Daniel Sánchez-Morillo
EBEsther Berrocoso
Esther Berrocoso