I-Jung Lee

Ms. I-Jung Lee

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Bor-Shing LinBor-Shing Lin
Bor-Shing Lin
ILI-Jung Lee
I-Jung Lee
SYShu-Yu Yang
Shu-Yu Yang
YLYi-Chiang Lo
Yi-Chiang Lo
JLJunghsi Lee
Junghsi Lee
JCJean-Lon Chen
Jean-Lon Chen
Capturing hand motions for hand function evaluations is essential in the medical field. Various data gloves have been developed for rehabilitation and manual dexterity assessments. This study proposed a modular data glove with 9-axis inertial measurement units (IMUs) to obtain static and dynamic parameters during hand function evaluation. A sensor fusion algorithm is used to calculate the range of motion of joints. The data glove is designed to have low cost, easy wearability, and high reliability. Owing to the modular design, the IMU board is independent and extensible and can be used with various microcontrollers to realize more medical applications. This design greatly enhances the stability and maintainability of the glove.

4 January 2022 in IEEE Access
Verified
Journal Article
Open access
Bor-Shing LinBor-Shing Lin
Bor-Shing Lin
TYTiku Yu
Tiku Yu
志維 彭志維 彭
志維 彭
CLChueh-Ho Lin
Chueh-Ho Lin
HHHung-Kai Hsu
Hung-Kai Hsu
ZZZhao Zhang
Zhao Zhang
Falls are the second leading cause of death from unintentional injuries in older adults. Although many systems have been used to detect falls, they are limited by the computational complexity of the algorithm. The images taken by the camera must be transmitted through a network to the back-end server for calculation. As the demand for Internet of Things increases, this architecture faces such problems as high bandwidth costs and server computing overload. Emerging methods reduce the workload of servers by transferring certain computing tasks from cloud servers to edge computing platforms. To this end, this study developed a fall detection system based on neuromorphic computing hardware, which streamlines and transplants the neural network model of the back-end computer to the edge computing platform. Through the neural network model with integer 8 bit precision deployed on the edge computing platform, the object photos obtained by the camera are converted into human motion features, and a support vector machine is then used for classification. After experimental evaluation, an accuracy of 96% was reached, the detection speed of the overall system was 11.5 frames per second, and the power consumption was 0.3 W. This system can monitor the fall events of older adults in real time and over a long period. All data were calculated on the edge computing platform. The system only reports fall events via Wi-Fi, thereby protecting the privacy of the user.


22 February 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Bor-Shing LinBor-Shing Lin
Bor-Shing Lin
ILI-Jung Lee
I-Jung Lee
SWShun-Pu Wang
Shun-Pu Wang
JCJean-Lon Chen
Jean-Lon Chen
Motion trajectory is a technology used in smart medicine, rehabilitation engineering, and interactive games. Studies have proposed several motion trajectory tracking systems based on inertial measurement units (IMUs). However, these systems are beset by problems such as low adaptability to various activities and the capacity for only two-dimensional trajectory estimation. To solve these problems, this study proposed a three-dimensional (3D) motion trajectory tracking system based on a residual neural network (ResNet) and bidirectional long short-term memory (Bi-LSTM) to estimate the user’s trajectory of daily activities. A participant was asked to wear the IMU device and perform two types of specified activities, namely hand-movement tasks and walking. Nine degrees of freedom data from the IMUs were collected during these activities and input into the deep learning model, which combines ResNet and Bi-LSTM, to detect features and predict the motion trajectory. Several experiments were conducted to obtain the optimal system architecture and parameter settings and to evaluate the accuracy of motion trajectory estimation. The accuracy of the proposed system was also compared with those in other studies. The results demonstrated that the relative trajectory error of walking is 0.81 m and that of general cases is 0.54 m, which all outperforms the other related studies. The evidence indicated that the proposed system can predict the 3D motion trajectory of daily activities accurately and can be easily applied to track the motion of most daily activities.

6 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Giovanni SaggioGiovanni Saggio
Giovanni Saggio
ACAlexandre Calado
Alexandre Calado
VEVito Errico
Vito Errico
Bor-Shing LinBor-Shing Lin
Bor-Shing Lin
ILI-Jung Lee
I-Jung Lee
Sensory gloves are devices capable of measuring finger movements and are useful in numerous applications, many of which require real-time data acquisition. However, the procedures explored in the literature to assess measurement repeatability and reliability mainly rely on static or quasi-static conditions. To overcome this limitation, here we propose a testing procedure for assessing measurements under dynamic conditions (slow, medium, and rapid finger joint movements). To this aim, we used two sensory gloves, one based on resistive flex sensors (RFSs) and another based on inertial measurement units (IMUs) – as two of the most adopted types. Our study demonstrated the feasibility of measuring dynamic finger movements and the differences in dynamic measurement repeatability and reliability between RFS- and IMU-based gloves when considering the angles (in degrees) of each finger joint. The RFS-based glove scored with an average range ± standard deviation (SD) of 6.84 ± 2.77°, and an intraclass correlation coefficient (ICC) of 0.77 ± 0.14, whereas the IMU-based glove scored with an average range of 8.49 ± 2.72°, and an ICC of 0.75 ± 0.14. Both gloves exhibited better repeatability and reliability at the slowest speed, with the RFS-based glove having an higher repeatability than the IMU-based one ( p < 0.001). Moreover, when compared to previous studies, the results (in terms of reliability and repeatability) here obtained under dynamic conditions are comparable to those obtained under static or quasi-static conditions. In summary, our results indicate that both proposed sensory gloves are suitable for most applications that require dynamic interactions.

28 April 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
BLBor-Shyh Lin
Bor-Shyh Lin
志維 彭志維 彭
志維 彭
ILI-Jung Lee
I-Jung Lee
HHHung-Kai Hsu
Hung-Kai Hsu
Bor-Shing LinBor-Shing Lin
Bor-Shing Lin
Bedside falls and pressure ulcers are crucial issues in geriatric care. Although many bedside monitoring systems have been proposed, they are limited by the computational complexity of their algorithms. Moreover, most of the data collected by the sensors of these systems must be transmitted to a back-end server for calculation. With an increase in the demand for the Internet of Things, problems such as higher cost of bandwidth and overload of server computing are faced when using the aforementioned systems. To reduce the server workload, certain computing tasks must be offloaded from cloud servers to edge computing platforms. In this study, a bedside monitoring system based on neuromorphic computing hardware was developed to detect bedside falls and sleeping posture. The artificial intelligence neural network executed on the back-end server was simplified and used on an edge computing platform. An integer 8-bit-precision neural network model was deployed on the edge computing platform to process the thermal image captured by the thermopile array sensing element to conduct sleep posture classification and bed position detection. The bounding box of the bed was then converted into the features for posture classification correction to correct the posture. In an experimental evaluation, the accuracy rate, inferencing speed, and power consumption of the developed system were 94.56%, 5.28 frames per second, and 1.5 W, respectively. All the calculations of the developed system are conducted on an edge computing platform, and the developed system only transmits fall events to the back-end server through Wi-Fi and protects user privacy.