Marco Gatti

Marco Gatti

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

12 January 2024 in Machines
Verified
Journal Article
Open access
PDF file
Henrique SimasHenrique Simas
Henrique Simas
Raffaele Di GregorioRaffaele Di Gregorio
Raffaele Di Gregorio
Roberto SimoniRoberto Simoni
Roberto Simoni
MGMarco Gatti
Marco Gatti
Robotic Total Stations (RTS) are fully automated theodolites with electronic distance measurement (EDM) that include a number of additional tools (e.g., camera, laser rangefinder, onboard computer, and tracking software, etc.) enabling them to work autonomously. The added tools make RTSs able to track mobile targets on civil structures thus opening to the use of RTSs in structural monitoring. Unfortunately, the available RTSs are able to track a target up to a motion rate of 3 Hz. Reducing mobile masses is a viable design strategy for extending this frequency border. Such a strategy is pursued in this study by proposing the use of parallel pointing systems (PPS) as basic mechanical architectures for RTSs. The literature on PPSs is reviewed and the applicable PPS architectures are selected. Successively, the selected architectures are sized according to RTSs’ functional requirements, and the positioning precision of the sized mechanisms is evaluated. The result of this study is that there are three PPS architectures suitable for RTSs, whose detailed comparison is also presented.

1 January 2018 in Geomatics, Natural Hazards and Risk
Verified
Journal Article
Open access
MGMarco Gatti
Marco Gatti
GPS measurements recorded at active sites in central Italy during the seismic events of greatest magnitude (24 August, 26 and 30 October 2016) were processed in kinematic mode according to the Precise Point Positioning (PPP) technique. The resulting data were the displacements and, by derivation with respect to time, the velocities and instantaneous horizontal accelerations. Elastic response spectra along the orthogonal walls of the site (if the GPS antenna was fixed to a building) or along the geographical directions (if the antenna was fixed to the ground) were obtained from the derived accelerations. The maximum amplitudes, i.e. peak vibrations, were then extracted from the response spectra. These peaks, unlike the co-seismic movements, represent the maximum instantaneous vibrations recorded following the shock produced by the seismic waves and thus are representative of both the discomfort perceived by the populations and the structural damage. This study shows that GPS is becoming an increasingly important tool to measure and monitor the dynamic responses of a structure. The results also provide a complete picture of the displacements induced by the seismic sequences in the earthquake-affected areas, leaving unresolved some questions concerning the localization of the phenomena and the causes of the structural deformations.

11 July 2018 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
MGMarco Gatti
Marco Gatti

20 April 2022 in Earthquake Engineering and Engineering Vibration
Verified
Journal Article
Closed access
PDF file
MGMarco Gatti
Marco Gatti

1 January 2020 in Geomatics, Natural Hazards and Risk
Verified
Journal Article
Open access
MGMarco Gatti
Marco Gatti
To exploit the purely geometric link between the elastic period of vibration T and the height H (or number of stories) of a building, T was varied from 0 to 0.5 s coinciding with a height between 0 and 12 m (at most the four stories typical of Italian buildings) in order to estimate the spectral accelerations corresponding to acceleration measurements recorded during the earthquakes of L’Aquila, Emilia and central Italy. These estimates were used to calculate the maximum dynamic amplification factors and corresponding heights, called critical heights, that can generate either resonance or appreciable dynamic amplification values. The results showed dynamic amplification values close to 3 for reinforced concrete buildings and 2.5 for masonry buildings independently of the characteristics of the earthquakes. There was a significant coincidence between the structural height of the buildings with greatest recorded damage and the critical height. The basis of the study lies in simple numerical steps carried out with easily obtainable data: for this reason, it can be easily applied to determine the vulnerability of a building according to its structural height.