LIDAN CHEN

Dr. LIDAN CHEN

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LCLIDAN CHEN
LIDAN CHEN
Keng Weng LaoKeng Weng Lao
Keng Weng Lao
YMYongliang Ma
Yongliang Ma
ZZZhe Zhang
Zhe Zhang
Using remote data analysis to estimate smart electricity meters (SMs) and detect SMs’ anomaly has aroused considerable discussion in power industry, because its lower cost and higher efficiency compared with the traditional field calibration. However, the trouble of lacking topology and parameter of the distribution grid and the ill-posed problem in SMs’ error estimation and anomaly detection (AD) are not well-resolved in most energy-conservation-theorem-based SM AD methods. This article presents a sorted Top-N AD mechanism to generate a list of suspicious anomalous SMs. The error estimation model (EEM) only using SMs’ electricity consumption data is investigated. The truncated singular value decomposition regularization with the L-curve optimization (TSVD+L) method is proposed to address the model’s ill-posedness. Three data processing modes, namely, one-pot mode, segmentation mode, and sliding window technique (SWT), are suggested to obtain multiple calculation results for SMs’ error comprehensive evaluation. The top $N$ % SMs in error sequence are proposed for onsite calibration instead of full inspection. The effectiveness and practicality of the proposed method are verified through both the simulation case and practical distribution network application. The results show that the proposed method has higher accuracy in SMs’ AD, compared with the ordinary least-squares (OLS) method, the recursive least-squares (RLS) method, and the Tikhonov regularization (Tik) method.

23 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
LCLIDAN CHEN
LIDAN CHEN
YZYao Zhang
Yao Zhang
AFAntonio Figueiredo
Antonio Figueiredo
Electric vehicles (EVs) can be regarded as a kind of demand response (DR) resource. Nevertheless, the EVs travel behavior is flexible and random, in addition, their willingness to participate in the DR event is uncertain, they are expected to be managed and utilized by the EV aggregator (EVA). In this perspective, this paper presents a composite methodology that take into account the dynamic road network (DRN) information and fuzzy user participation (FUP) for obtaining spatio-temporal projections of demand response potential from electric vehicles and the electric vehicle aggregator. A dynamic traffic network model taking over the traffic time-varying information is developed by graph theory. The trip chain based on housing travel survey is set up, where Dijkstra algorithm is employed to plan the optimal route of EVs, in order to find the travel distance and travel time of each trip of EVs. To demonstrate the uncertainties of the EVs travel pattern, simulation analysis is conducted using Monte Carlo method. Subsequently, we suggest a fuzzy logic-based approach to uncertainty analysis that starts with investigating EV users’ subjective ability to participate in DR event, and we develop the FUP response mechanism which is constructed by three factors including the remaining dwell time, remaining SOC, and incentive electricity pricing. The FUP is used to calculate the real-time participation level of a single EV. Finally, we take advantage of a simulation example with a coupled 25-node road network and 54-node power distribution system to demonstrate the effectiveness of the proposed method.

20 October 2025 in Electronics
Verified
Journal Article
Open access
PDF file
LCLIDAN CHEN
LIDAN CHEN
GFGUANGXU FENG
GUANGXU FENG
LWLei Wang
Lei Wang
The ongoing evolution of cyber-physical power systems renders them susceptible to frequent and multifaceted electrical disturbances. Critically, missingness resulting from cascading cyber-physical failures severely impedes the ability to accurately monitor and diagnose these electrical disturbances. To address this serious challenge, this paper proposes a novel gating adversarial imputation (GAI) framework specially tailored for the high-fidelity restoration of missing electrical disturbance data. The proposed GAI efficiently introduces the latest gating mechanism into a stability-improved adversarial imputation process, enabling robust feature representation while maintaining high imputation accuracy. To validate its efficacy, a synthetic dataset encompassing 15 distinct disturbance types is constructed based on precise mathematical equations and standard missingness. A comprehensive experimental evaluation demonstrates that the proposed GAI consistently outperforms five representative imputation benchmarks across all tested missing percentages. Moreover, GAI effectively preserves the original critical characteristics during data recovery, thereby enhancing accurate system monitoring and operational security.

3 September 2025 in Processes
Verified
Journal Article
Open access
PDF file
LCLIDAN CHEN
LIDAN CHEN
JGJianhua Gong
Jianhua Gong
LLLi Liu
Li Liu
Keng Weng LaoKeng Weng Lao
Keng Weng Lao
LWLei Wang
Lei Wang
Emerging power electronic devices like soft open points (SOPs) and electric springs (ESs) play a vital role in enhancing active distribution network (ADN) efficiency. SOPs enable flexible active/reactive power control, while ESs improve demand-side management and voltage regulation. This paper proposes a two-stage stochastic programming model to optimize ADN’s operation by coordinating these fast-response devices with legacy mechanical equipment. The first stage determines hourly setpoints for conventional devices, while the second stage adjusts SOPs and ESs for intra-hour control. To handle ES nonlinearities, a hybrid data–knowledge approach combines knowledge-based linear constraints with a data-driven multi-layer perceptron, later linearized for computational efficiency. The resulting mixed-integer second-order cone program is solved using commercial solvers. Simulation results show the proposed strategy effectively reduces power loss by 42.5%, avoids voltage unsafety with 22 time slots, and enhances 4.3% PV harvesting. The coordinated use of SOP and ESs significantly improves system efficiency, while the proposed solution methodology ensures both accuracy and over 60% computation time reduction.

7 April 2025 in Symmetry
Verified
Journal Article
Open access
PDF file
LWLei Wang
Lei Wang
LCLIDAN CHEN
LIDAN CHEN
WMW. Ma
W. Ma
JLJubao Li
Jubao Li
It has been confirmed that a larger stability domain has more advantages for system operation. In this paper, a novel one-cycle control (OCC) embedded with a composite function is proposed. Its control principle is based on maintaining the symmetry of the volt-second value for the inductor in each cycle. Then, selecting the reference voltage as the study variable, the stability boundaries and identify stable parameter domains are studied by establishing a state-space average model. The results demonstrate that, compared with the conventional OCC, the proposed OCC with composite function u embedded achieves an expanded stable parameter domain, effectively delaying the occurrence of instability phenomena from uref=2uin to uref=3uin. Both the simulation and experimental results conclusively validate the theoretical analysis, confirming the effectiveness and superiority of the proposed control strategy.

8 June 2023 in Electronics
Verified
Journal Article
Open access
PDF file
LWLei Wang
Lei Wang
LCLIDAN CHEN
LIDAN CHEN
LWLei Wang
Lei Wang
WMW. Ma
W. Ma
Cascaded multilevel converters are promising candidates for grid-connected PV systems, but low-frequency ripples may exist in a DC link. Such ripples are not just inherent; they can occur due to environmental factors, such as variations in a certain range of irradiance of the PV. To address this issue, this article proposes a clock phase-shifted (CPS) energy balance control method for grid-connected cascaded multilevel inverters for photovoltaic (PV) systems. The proposed control scheme can prevent the low-frequency ripple of the DC link propagating to the power grid. Furthermore, it is feasible in principle and no adjustment of the control parameters is needed. The simulation and experimental results verify the effectiveness and feasibility of the proposed approach.