Director of SMALL (Sensors and MicroActuators Learning Lab) Department of Electrical Engineering and Department of Biomedical Engineering State University of New York at Buffalo (SUNY-Buffalo), Buffalo, NY 14260, USA
Prof. Dr. Kwang W. Oh
Director of SMALL (Sensors and MicroActuators Learning Lab) Department of Electrical Engineering and Department of Biomedical Engineering State University of New York at Buffalo (SUNY-Buffalo), Buffalo, NY 14260, USA
This article reviews the application of electric circuit methods for the analysis of pressure-driven microfluidic networks with an emphasis on concentration- and flow-dependent systems. The application of circuit methods to microfluidics is based on the analogous behaviour of hydraulic and electric circuits with correlations of pressure to voltage, volumetric flow rate to current, and hydraulic to electric resistance. Circuit analysis enables rapid predictions of pressure-driven laminar flow in microchannels and is very useful for designing complex microfluidic networks in advance of fabrication. This article provides a comprehensive overview of the physics of pressure-driven laminar flow, the formal analogy between electric and hydraulic circuits, applications of circuit theory to microfluidic network-based devices, recent development and applications of concentration- and flow-dependent microfluidic networks, and promising future applications. The lab-on-a-chip (LOC) and microfluidics community will gain insightful ideas and practical design strategies for developing unique microfluidic network-based devices to address a broad range of biological, chemical, pharmaceutical, and other scientific and technical challenges.
This article provides a comprehensive overview of the physics of the gas solubility and permeability of PDMS, a systematic review of different types of vacuum-driven power-free microfluidics, design guidelines, existing applications, and the outlook.
In this paper, we propose a generalized serial dilution module for universal microfluidic concentration gradient generators including N cascaded-mixing stages in a stepwise manner. Desired concentrations were generated by means of controlled volumetric mixing ratios of two merging solutions in each stage. The flow rates were adjusted by controlling channel length, which is proportional to fluidic resistance in each channel. A generalized mathematical model for generating any complex concentration and output flow rate gradients is presented based on the fact that there is an analogy between microfluidic circuits and electrical circuits. The pressure drop corresponds to a voltage drop, the flow rate to an electrical current, and the flow resistance to an electrical resistance. A simple equivalent electrical circuit model was generalized, and in the model each channel segment was represented by an electrical resistance. As a result of the mathematical modelling, the only variable parameter in the generalized serial dilution module was the channel length. By the use of the generalized serial dilution module with N = 4, three types of microfluidic gradient generators for linear, logarithmic and Gaussian gradients were successfully designed and tested. The proposed strategy is capable of generating universal monotonic gradients with a single module or arbitrary gradients with multiple modules ranging from linear to complex non-linear shapes of concentration gradients as well as arbitrary output flow rate gradients in a stepwise manner. The simple universal gradient generation technology using the generalized serial dilution module will find widespread use in the greater chemical and biological community, and address many challenges of gradient-dependent phenomena.
Here we report the development of a programmable and fully automatic gold array-embedded gradient microfluidic chip that integrates a gradient microfluidic device with gold-patterned microarray wells. This device provides a convenient and reproducible surface-enhanced Raman scattering (SERS)-based immunoassay platform for cancer biomarkers. We used hollow gold nanospheres (HGNs) as SERS agents because of their highly sensitive and reproducible characteristics. The utility of this platform was demonstrated by the quantitative immunoassay of alpha-fetoprotein (AFP) model protein marker. Our proposed SERS-based immunoassay platform has many advantages over other previously reported SERS immunoassay methods. The tedious manual dilution process of repetitive pipetting and inaccurate dilution is eliminated with this process because various concentrations of biomarker are automatically generated by microfluidic gradient generators with N cascade-mixing stages. The total assay time from serial dilution to SERS detection takes less than 60 min because all of the experimental conditions for the formation and detection of immunocomplexes can be automatically controlled inside the exquisitely designed microfluidic channel. Thus, this novel SERS-based microfluidic assay technique is expected to be a powerful clinical tool for fast and sensitive cancer marker detection.
Suitable micropumping methods for flow control represent a major technical hurdle in the development of microfluidic systems for point-of-care testing (POCT). Passive micropumping for point-of-care microfluidic systems provides a promising solution to such challenges, in particular, passive micropumping based on capillary force and air transfer based on the air solubility and air permeability of specific materials. There have been numerous developments and applications of micropumping techniques that are relevant to the use in POCT. Compared with active pumping methods such as syringe pumps or pressure pumps, where the flow rate can be well-tuned independent of the design of the microfluidic devices or the property of the liquids, most passive micropumping methods still suffer flow-control problems. For example, the flow rate may be set once the device has been made, and the properties of liquids may affect the flow rate. However, the advantages of passive micropumping, which include simplicity, ease of use, and low cost, make it the best choice for POCT. Here, we present a systematic review of different types of passive micropumping that are suitable for POCT, alongside existing applications based on passive micropumping. Future trends in passive micropumping are also discussed.
19 August 2019 in IEEE Transactions on Biomedical Engineering
Objective: We present a new photoacoustic tomography system that provides visualization of angiographic features in a human breast with mammogram-like images. Methods: The system images a mildly compressed breast, from both top and bottom, using two 128-element, 2.25 MHz linear transducer arrays and line optical fiber bundles. The mild compression is achieved using plastic films, which is a more comfortable experience for the patient compared to rigid metal plates used in a traditional mammogram. Results: We could image a D cup-sized breast of 7 cm thickness within 1 minute and achieved a spatial resolution of around 1 mm in all directions. Conclusion: Our system possesses the benefits of portability, speedy scanning, and patient comfort. The craniocaudal-view images can be easily correlated with existing imaging modalities for data interpretation. Significance: Early cancer detection plays a critical role in overall cancer survival rate. Our system may address the limitations of mammogram and offer a radiation-free screening technique for patients with dense breasts.