Objective: We present a new photoacoustic tomography system that provides visualization of angiographic features in a human breast with mammogram-like images. Methods: The system images a mildly compressed breast, from both top and bottom, using two 128-element, 2.25 MHz linear transducer arrays and line optical fiber bundles. The mild compression is achieved using plastic films, which is a more comfortable experience for the patient compared to rigid metal plates used in a traditional mammogram. Results: We could image a D cup-sized breast of 7 cm thickness within 1 minute and achieved a spatial resolution of around 1 mm in all directions. Conclusion: Our system possesses the benefits of portability, speedy scanning, and patient comfort. The craniocaudal-view images can be easily correlated with existing imaging modalities for data interpretation. Significance: Early cancer detection plays a critical role in overall cancer survival rate. Our system may address the limitations of mammogram and offer a radiation-free screening technique for patients with dense breasts.
Sonodynamic therapy (SDT) has emerged as an important modality for cancer treatment. SDT utilizes ultrasound excitation, which overcomes the limitations of light penetration in deep tumors, as encountered by photodynamic therapy (PDT) which uses optical excitations. A comparative study of these modalities using the same sensitizer drug can provide an assessment of their effects. However, the efficiency of SDT and PDT is low in a hypoxic tumor environment, which limits their applications. In this study, we report a hierarchical nanoformulation which contains a Food and Drug Administration (FDA) approved sensitizer chlorin, e6, and a uniquely stable high loading capacity oxygen carrier, perfluoropolyether. This oxygen carrier possesses no measurable cytotoxicity. It delivers oxygen to overcome hypoxia, and at the same time, boosts the efficiency of both SDT and PDT. Moreover, we comparatively analyzed the efficiency of SDT and PDT for tumor treatment throughout the depth of the tissue. Our study demonstrates that the strengths of PDT and SDT could be combined into a single multifunctional nanoplatform, which works well in the hypoxia environment and overcomes the limitations of each modality. The combination of deep tissue penetration by ultrasound and high spatial activation by light for selective treatment of single cells will significantly enhance the scope for therapeutic applications.
At present, there is a lack of commercially available test phantoms specifically designed for the photoacoustic (PA) field that encompass all desired parameters and applications of this technology. This review examines the existing phantoms in well-established imaging domains, such as magnetic resonance imaging (MRI), ultrasound, optics, and positron imaging technology. By investigating phantom development and manufacturing in these established imaging fields, valuable patterns can be identified and analyzed. The systematic grouping and organization of the identified patterns, materials, and methods serve as a foundational framework for the development of various phantoms tailored to different PA imaging applications. This approach effectively minimizes the requirement for extensive development of individualized PA phantoms, thereby accelerating the commercialization and research efforts in the field of PA technology.
Linear-array-based photoacoustic computed tomography (PACT) has been widely used in vascular imaging due to its low cost and high compatibility with current ultrasound systems. However, linear-array transducers have inherent limitations for three-dimensional imaging due to the poor elevation resolution. In this study, we introduced a deep learning-assisted data process algorithm to enhance the image quality in linear-array-based PACT. Compared to our earlier study where training was performed on 2D reconstructed data, here, we utilized 2D and 3D reconstructed data to train the two networks separately. We then fused the image data from both 2D and 3D training to get features from both algorithms. The numerical and in vivo validations indicate that our approach can improve elevation resolution, recover the true size of the object, and enhance deep vessels. Our deep learning-assisted approach can be applied to translational imaging applications that require detailed visualization of vascular features.
Pulsatile signal detection plays an important role in monitoring various physiological parameters, primarily heart rate and blood oxygen saturation. Their applications range from clinical settings to personal health and wellness monitoring. PPG (photoplethysmography) can provide non-invasive optical measurements to detect blood volume changes in peripheral tissues. Yet, it suffers from low spatial resolution to precisely detect the pulsatile signal originating over 2 mm in human tissue. Ultrasound (US) provides a deep detectable range compared to the pure optical method. However, its low contrast to red blood cells and cluster artifacts makes it only detect the indirect pulsation from the surrounding tissue of blood vessels. Recent advances in PA imaging show its capability to precisely measure pulsatile signals originating from blood vessels in deep regions (over 10 mm) and its potential to accurately record blood oxygen saturation with high spatial and temporal resolution. This review article summarizes studies on photoacoustic (PA) pulsatile signal monitoring, highlights the technical advances, and compares it against optical and ultrasonic approaches.
Pulsatile signal detection plays an important role in monitoring various physiological parameters, primarily heart rate and blood oxygen saturation. Their applications range from clinical settings to personal health and wellness monitoring. PPG (photoplethysmography) can provide non-invasive optical measurements to detect blood volume changes in peripheral tissues. Yet, it suffers from low spatial resolution to precisely detect the pulsatile signal originating over 2mm in human tissue. Ultrasound provides a deep detectable range compared to the pure optical method. However, its low contrast to red blood cells and cluster artifacts makes it only detect the indirect pulsation from the surrounding tissue of blood vessels. Recent advances in PA imaging show its capability to precisely measure pulsatile signals originating from blood vessels in deep regions (over 10 mm) and its potential to accurately record blood oxygen saturation with high spatial and temporal resolution. This review article will summarize studies on photoacoustic (PA) pulsatile signal monitoring, highlight the technical advances, and compare it against optical and ultrasonic approaches.