Khalid Rehman

Dr. Khalid Rehman

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
AAAhmad Alzahrani
Ahmad Alzahrani
Ghulam HafeezGhulam Hafeez
Ghulam Hafeez
SASajjad Ali
Sajjad Ali
SMSadia Murawwat
Sadia Murawwat
MKMuhammad Iftikhar Khan
Muhammad Iftikhar Khan
AAAzher Abed
Azher Abed
Multi-objective energy optimization is indispensable for energy balancing and reliable operation of smart power grid (SPG). Nonetheless, multi-objective optimization is challenging due to uncertainty and multi-conflicting parameters at both the generation and demand sides. Thus, opting for a model that can solve load and distributed energy source scheduling problems is necessary. This work presents a model for operation cost and pollution emission optimization with renewable generation in the SPG. Solar photovoltaic and wind are renewable energy which have a fluctuating and uncertain nature. The proposed system uses the probability density function (PDF) to address uncertainty of renewable generation. The developed model is based on a multi-objective wind-driven optimization (MOWDO) algorithm to solve a multi-objective energy optimization problem. To validate the performance of the proposed model a multi-objective particle swarm optimization (MOPSO) algorithm is used as a benchmark model. Findings reveal that MOWDO minimizes the operational cost and pollution emission by 11.91% and 6.12%, respectively. The findings demonstrate that the developed model outperforms the comparative models in accomplishing the desired goals.

17 June 2022 in Processes
Verified
Journal Article
Open access
PDF file
FAFahad Albogamy
Fahad Albogamy
Yasir AshfaqYasir Ashfaq
Yasir Ashfaq
Ghulam HafeezGhulam Hafeez
Ghulam Hafeez
SMSadia Murawwat
Sadia Murawwat
SKSheraz Khan
Sheraz Khan
KRKhalid Rehman
Khalid Rehman
This work proposes a framework to solve demand-side management (DSM) problem by systematically scheduling energy consumption using flat pricing scheme (FPS) in smart grid (SG). The framework includes microgrid with renewable energy sources (solar and wind), energy storage systems, electric vehicles (EVs), and building appliances like time flexible, power flexible, and base/critical appliances. For the proposed framework, we develop an ant colony optimization (ACO) algorithm, which efficiently schedules smart appliances, and EVs batteries charging/discharging with microgrid and without (W/O) microgrid under FPS to minimize energy cost, carbon emission, and peak to average ratio (PAR). An integrated technique of enhanced differential evolution (EDE) algorithm and artificial neural network (ANN) is devised to predict solar irradiance and wind speed for accurate microgrid energy estimation. To endorse the applicability of the proposed framework, simulations are conducted. Moreover, the proposed framework based on the ACO algorithm is compared to mixed-integer linear programming (MILP) and W/O scheduling energy management frameworks in terms of energy cost, carbon emission, and PAR. The developed ACO algorithm reduces energy cost, PAR, and carbon emission by 23.69%, 26.20%, and 15.35% in scenario I, and 25.09%, 31.45%, and 18.50% in scenario II, respectively, as compared to W/O scheduling case. The results affirm the applicability of the proposed framework in aspects of the desired objectives.

19 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
IUIbrar Ullah
Ibrar Ullah
Irshad HussainIrshad Hussain
Irshad Hussain
KRKhalid Rehman
Khalid Rehman
PWPiotr Wróblewski
Piotr Wróblewski
WLWojciech Lewicki
Wojciech Lewicki
Balasubramanian Prabhu kavinBalasubramanian Prabhu kavin
Balasubramanian Prabhu kavin
Unbalanced load condition is one of the major issues of all commercial, industrial and residential sectors. Unbalanced load means that, when different loads are distributed on a three-phase four-wire system, unequal currents pass through the three phases. Due to it, a heavy current flows in the neutral wire, which not only adds the losses, but also puts constraints on three phases’ loads. In this paper, we have presented a practical approach for load balancing. First, we have considered the existing three-phase load system where the supply is a three-phase unbalanced supply. Before balancing the load, it is necessary to compensate the current in neutral wire. A nature-inspired moth–flame optimization (MFO) algorithm is used to propose a scheme for balancing of current in neutral wire. The information of a distributed single-phase load was used to balance the currents in a three-phase system. The feeder phase and load profiles of each single-phase load are used to reconfigure the network using an optimization process. By balancing the current of three phases, the current of the neutral conductor in substation transformers was reduced to almost zero.

20 August 2022 in Processes
Verified
Journal Article
Open access
PDF file
SUSana Ullah
Sana Ullah
Ghulam HafeezGhulam Hafeez
Ghulam Hafeez
GRGul Rukh
Gul Rukh
FAFahad Albogamy
Fahad Albogamy
SMSadia Murawwat
Sadia Murawwat
KRKhalid Rehman
Khalid Rehman
Agricultural productivity plays a vital role in a country’s economy, which can be increased by providing the proper water needed for crops. Proper water provision ensures suitable moisture and appropriate conditions essential for crops, water resource preservation, minimized water wastage, and energy consumption. However, adequate water provision is challenging due to intermittent and uncertain environmental and weather conditions. On this note, a model with uncertain and stochastic conditions (rain, wet, dry, humidity, and moisture) capturing abilities is needed. Thus, a smart-sensors-based solar-powered system is developed for monitoring and controlling the tube well that ensures proper water provision to crops. The developed system properly checks weather and environmental conditions (rain, temperature, irradiance, humidity, etc.), soil conditions (wet or dry), and crop conditions to monitor and regulate water flow accordingly to minimize water and energy consumption wastage. The developed system is an integrated system of four modules: Arduino with a built-in Atmel AT mega microcontroller, sensors, solar power, and a global system for mobile communication (GSM). The GSM module exchanges acknowledgement messages with the operator and controller about the various statuses, such as weather and environmental conditions, soil conditions (wet or dry), crop conditions, and the toggle status of the motor (OFF, ON/main power supply, or solar power). In order for the controller module to determine the motor state, the sensors module computes many parameters, including rain, wet, dry, humidity, and moisture. In addition, the sensor module also prevents the motor from dry running. The developed smart irrigation system is superior to existing irrigation systems in aspects of water wastage and energy consumption minimization.

30 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
Taimoor Ahmad KhanTaimoor Ahmad Khan
Taimoor Ahmad Khan
AUAmjad Ullah
Amjad Ullah
Ghulam HafeezGhulam Hafeez
Ghulam Hafeez
IKImran Khan
Imran Khan
SMSadia Murawwat
Sadia Murawwat
KRKhalid Rehman
Khalid Rehman
A real-time energy management strategy using dynamic pricing mechanism by deploying a fractional order super twisting sliding mode controller (FOSTSMC) is proposed for correspondence between energy users and providers. This framework, which controls the energy demand of the smart grid’s users is managed by the pricing signal provided by the FOSTSMC, issued to the smart meters, and adjusts the users’ demand to remove the difference between energy demand and generation. For the implementation purpose, a scenario based in MATLAB/Simulink is constructed where a sample renewable energy–integrated smart microgrid is considered. For the validation of the framework, the results of FOSTSMC are compared with the benchmark PI controller’s response. The results of the benchmark PI controller are firstly compared in step response analysis, which is followed by the comparison in deploying in renewable energy–integrated smart grid scenario with multiple users. The results indicate that the FOSTSMC-based controller strategy outperformed the existing PI controller-based strategy in terms of overshoot, energy balance, and energy price regulation.

27 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
Abuzar KhanAbuzar Khan
Abuzar Khan
KRKhalid Rehman
Khalid Rehman
AJAhmad Junaid
Ahmad Junaid
AIAbid Iqbal
Abid Iqbal
Muhammad Farooq SiddiqueMuhammad Farooq Siddique
Muhammad Farooq Siddique
GHGhassan Husnain
Ghassan Husnain
Occupational mental-health risk in knowledge-work settings is an important public-health and psychosocial-support concern because workload demands, career insecurity, limited mentoring, uneven institutional support and barriers to care can increase psychological risk, including in early-career academic environments. Workplace well-being assessments rely on aggregate survey summaries or conventional prediction models, limiting calibration, interpretability, subgroup evaluation and transfer validation. This study develops a computational-intelligence framework for public mental-health decision support using heterogeneous workplace survey data with early-career academics treated as a motivating knowledge-work context rather than as the direct empirical cohort. The proposed approach combines attention-based tabular learning, variational autoencoder latent profiling, stacked ensemble prediction, probability calibration, feature attribution, perturbation analysis, fairness assessment and cross-dataset adaptation. Calibrated probabilities are converted into a transparent 0–100 risk index to support preventive outreach, psychosocial-support planning and resource-allocation decisions. The model is compared with baselines, including logistic regression, support vector machine, random forest, XGBoost, LightGBM, CatBoost, TabNet, FT–Transformer, NODE and DCN. Results show strong held-out performance with AUC = 0.885, average precision = 0.872, F1 = 0.808, Brier score = 0.145 and expected calibration error = 0.022, outperforming tested baselines. Five-fold robustness analysis produced a conservative mean test AUC of 0.809±0.044, indicating moderate partition sensitivity. Key predictors include work interference, perceived stress, care access and support variables. Latent profiling identifies two behavioural subgroups with distinct risk patterns. After feature harmonization, target-domain adaptation and recalibration, external evaluation on an occupational burnout dataset achieves AUC = 0.941 and average precision = 0.936, supporting calibrated, interpretable and subgroup-aware decision support under dataset shift.