Recently, the use of new and renewable energy sources to reduce carbon dioxide emissions and minimize global warming has attracted attention. Among the different renewable energy sources, solar energy is utilized for energy reduction in buildings because of its ease of use and excellent maintenance and repair. In this study, an air-based photovoltaic/thermal (PVT) system that improves solar energy utilization was developed, and its performance was experimentally compared with that of the existing photovoltaic (PV) system. The PVT system could increase the amount of generated power by decreasing the panel temperature raised by the air passing through the lower part of the panel. Moreover, it was possible to use the high-temperature air collected from the panel for heating or hot-water supply in the building. Based on the experimental results obtained for the PV and PVT panels subjected to the same weather conditions, the power generation efficiency of the PVT panel through which air was passed increased by approximately 10.1% compared to that of the PV panel. In addition, a heat collection efficiency of approximately 46.6% was generated by the temperature increase of the air passing through the PVT panel.
Through a comprehensive evaluation of the spaces of 25 railway stations, where power-saving operations are being conducted due to an earthquake, the effects of various components of the space on users’ psychology were reviewed. For the platforms of railway stations, which are divided into ‘island platforms’ and ‘side platforms’ the ‘physical quantity measurement’ and ‘impression evaluation’ were assessed. When a simple power-saving method, such as partial lighting up is adopted, it has been shown that there is a negative effect on the users, both physically and psychologically. In particular, in the case of outdoor platforms, there is a concern that glare and anxiety due to contrast may increase; therefore, it is necessary to utilize the reflective surfaces effectively. Floor illuminance is fundamental to lighting design. However, some areas cannot be evaluated by floor illuminance alone. The difference in the results of the impression evaluation in five areas with floor illuminance around 50 lx was widely distributed, and it was found that the shape and material of the space affected the results. If platform screen doors are installed, a lighting method that can evenly illuminate the interior of the space is necessary. By reviewing each factor that determines the visual impression, it was revealed that the lighting location and lighting method were significantly affected.