Anthony E. G. Cass

Prof. Anthony E. G. Cass


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
JSJasmine Y. Y. Sze
Jasmine Y. Y. Sze
AIAleksandar Ivanov
Aleksandar Ivanov
ACAnthony E. G. Cass
Anthony E. G. Cass
JEJoshua B. Edel
Joshua B. Edel
The capability to screen a range of proteins at the single-molecule level with enhanced selectivity in biological fluids has been in part a driving force in developing future diagnostic and therapeutic strategies. The combination of nanopore sensing and nucleic acid aptamer recognition comes close to this ideal due to the ease of multiplexing, without the need for expensive labelling methods or extensive sample pre-treatment. Here, we demonstrate a fully flexible, scalable and low-cost detection platform to sense multiple protein targets simultaneously by grafting specific sequences along the backbone of a double-stranded DNA carrier. Protein bound to the aptamer produces unique ionic current signatures which facilitates accurate target recognition. This powerful approach allows us to differentiate individual protein sizes via characteristic changes in the sub-peak current. Furthermore, we show that by using DNA carriers it is possible to perform single-molecule screening in human serum at ultra-low protein concentrations.

5 April 2019 in ACS Sensors
Verified
Journal Article
Open access
SGSally A. N. Gowers
Sally A. N. Gowers
DFDavid M. E. Freeman
David M. E. Freeman
TRTimothy Rawson
Timothy Rawson
MRMichelle L. Rogers
Michelle L. Rogers
RWRichard C. Wilson
Richard C. Wilson
DODanny O’hAre
Danny O’hAre
Antimicrobial resistance poses a global threat to patient health. Improving the use and effectiveness of antimicrobials is critical in addressing this issue. This includes optimising the dose of antibiotic delivered to each individual. New sensing approaches that track antimicrobial concentration for each patient in real time could allow individualised drug dosing. This work presents a potentiometric microneedle-based biosensor to detect levels of β-lactam antibiotics in vivo in a healthy human volunteer. The biosensor is coated with a pH-sensitive iridium oxide layer, which detects changes in local pH as a result of β-lactam hydrolysis by β-lactamase immobilised on the electrode surface. Development and optimisation of the biosensor coatings are presented, giving a limit of detection of 6.8 µM in 10 mM PBS solution. Biosensors were found to be stable for up to two weeks at -20○C and to withstand sterilisation. Sensitivity was retained after application for 6 hours in vivo. Proof-of-concept results are presented showing that penicillin concentrations measured using the microneedle-based biosensor track those measured using both discrete blood and microdialysis sampling in vivo. These preliminary results show the potential of this microneedle-based biosensor to provide a minimally-invasive means to measure real-time β-lactam concentrations in vivo, representing an important first step towards a closed-loop therapeutic drug monitoring system.

22 June 2021 in Nature Reviews Microbiology
Verified
Journal Article
Closed access
PDF file
TRTimothy Rawson
Timothy Rawson
RWRichard C. Wilson
Richard C. Wilson
DODanny O’hAre
Danny O’hAre
PHPau Herrero
Pau Herrero
AKAndrew Kambugu
Andrew Kambugu
AHAlison Holmes
Alison Holmes

4 March 2019 in ACS Nano
Verified
Journal Article
Open access
CHCatherine S. Hansel
Catherine S. Hansel
SCSpencer W. Crowder
Spencer W. Crowder
SCSamuel Cooper
Samuel Cooper
SGSahana Gopal
Sahana Gopal
MCMaria João Pardelha da Cruz
Maria João Pardelha da Cruz
MSMolly M. Stevens
Molly M. Stevens
Biomaterial substrates can be engineered to present topographical signals to cells which, through interactions between the material and active components of the cell membrane, regulate key cellular processes and guide cell fate decisions. However, targeting mechanoresponsive elements that reside within the intracellular domain is a concept that has only recently emerged. Here, we show that mesoporous silicon nanoneedle arrays interact simultaneously with the cell membrane, cytoskeleton, and nucleus of primary human cells, generating distinct responses at each of these cellular compartments. Specifically, nanoneedles inhibit focal adhesion maturation at the membrane, reduce tension in the cytoskeleton, and lead to remodeling of the nuclear envelope at sites of impingement. The combined changes in actin cytoskeleton assembly, expression and segregation of the nuclear lamina, and localization of Yes-associated protein (YAP) correlate differently from what is canonically observed upon stimulation at the cell membrane, revealing that biophysical cues directed to the intracellular space can generate heretofore unobserved mechanosensory responses. These findings highlight the ability of nanoneedles to study and direct the phenotype of large cell populations simultaneously, through biophysical interactions with multiple mechanoresponsive components.

15 October 2016 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
SSSanjiv Sharma
Sanjiv Sharma
ZHZhenyi Huang
Zhenyi Huang
MRMichelle Rogers
Michelle Rogers
MBMartyn Boutelle
Martyn Boutelle
ACAnthony E. G. Cass
Anthony E. G. Cass
We describe here a minimally invasive glucose biosensor based on a microneedle array electrode fabricated from an epoxy-based negative photoresist (SU8 50) and designed for continuous measurement in the dermal compartment with minimal pain. These minimally invasive, continuous monitoring sensor devices (MICoMS) were produced by casting the structures in SU8 50, crosslinking and then metallising them with platinum or silver to obtain the working and reference electrodes, respectively. The metallised microneedle array electrodes were subsequently functionalised by entrapping glucose oxidase in electropolymerised polyphenol (PP) film. Sensor performance in vitro showed that glucose concentrations down to 0.5 mM could be measured with a response times (T90) of 15 s. The effect of sterilisation by Co60 irradiation was evaluated. In preparation for further clinical studies, these sensors were tested in vivo in a healthy volunteer for a period of 3–6 h. The sensor currents were compared against point measurements obtained with a commercial capillary blood glucometer. The epoxy MICoMS devices showed currents values that could be correlated with these. Microneedle arrays for continuous glucose monitoring in dermal interstitial fluid

21 March 2018 in Analytical Methods
Verified
Journal Article
Open access
PDF file
SSSanjiv Sharma
Sanjiv Sharma
AEAhmed El-Laboudi
Ahmed El-Laboudi
MRMonika Reddy
Monika Reddy
NJNarvada Jugnee
Narvada Jugnee
SSSujan Sivasubramaniyam
Sujan Sivasubramaniyam
ACAnthony E. G. Cass
Anthony E. G. Cass
Although subcutaneously implanted continuous glucose monitoring (CGM) devices have been shown to support diabetes self-management, their uptake remains low due to high costs and poor accuracy and precision arising from their invasiveness.