Sanjiv Sharma

Dr. Sanjiv Sharma

College of Engineering, Swansea University, Swansea, (UK)
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2008 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
AHAnsgar Huebner
Ansgar Huebner
SSSanjiv Sharma
Sanjiv Sharma
MSMonpichar Srisa-Art
Monpichar Srisa-Art
FHFlorian Hollfelder
Florian Hollfelder
JEJoshua B. Edel
Joshua B. Edel
ADAndrew Demello
Andrew Demello
The exploitation of microdroplets produced within microfluidic environments has recently emerged as a new and exciting technological platform for applications within the chemical and biological sciences. Interest in microfluidic systems has been stimulated by a range of fundamental features that accompany system miniaturization. Such features include the ability to process and handle small volumes of fluid, improved analytical performance when compared to macroscale analogues, reduced instrumental footprints, low unit cost, facile integration of functional components and the exploitation of atypical fluid dynamics to control molecules in both time and space. Moreover, microfluidic systems that generate and utilize a stream of sub-nanolitre droplets dispersed within an immiscible continuous phase have the added advantage of allowing ultra-high throughput experimentation and being able to mimic conditions similar to that of a single cell (in terms of volume, pH, and salt concentration) thereby compartmentalizing biological and chemical reactions. This review provides an overview of methods for generating, controlling and manipulating droplets. Furthermore, we discuss key fields of use in which such systems may make a significant impact, with particular emphasis on novel applications in the biological and physical sciences.

1 January 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Paolo BollellaPaolo Bollella
Paolo Bollella
SSSanjiv Sharma
Sanjiv Sharma
ACAnthony Edward George Cass
Anthony Edward George Cass
RARiccarda Antiochia
Riccarda Antiochia

1 November 2019 in The Lancet Digital Health
Verified
Journal Article
Open access
TRTimothy Rawson
Timothy Rawson
SGSally A N Gowers
Sally A N Gowers
DFDavid M E Freeman
David M E Freeman
RWRichard C Wilson
Richard C Wilson
SSSanjiv Sharma
Sanjiv Sharma
AHAlison Holmes
Alison Holmes
Enhanced methods of drug monitoring are required to support the individualisation of antibiotic dosing. We report the first-in-human evaluation of real-time phenoxymethylpenicillin monitoring using a minimally invasive microneedle-based β-lactam biosensor in healthy volunteers. This first-in-human, proof-of-concept study was done at the National Institute of Health Research/Wellcome Trust Imperial Clinical Research Facility (Imperial College London, London, UK). The study was approved by London-Harrow Regional Ethics Committee. Volunteers were identified through emails sent to a healthy volunteer database from the Imperial College Clinical Research Facility. Volunteers, who had to be older than 18 years, were excluded if they had evidence of active infection, allergies to penicillin, were at high risk of skin infection, or presented with anaemia during screening. Participants wore a solid microneedle β-lactam biosensor for up to 6 h while being dosed at steady state with oral phenoxymethylpenicillin (five 500 mg doses every 6 h). On arrival at the study centre, two microneedle sensors were applied to the participant's forearm. Blood samples (via cannula, at -30, 0, 10, 20, 30, 45, 60, 90, 120, 150, 180, 210, 240 min) and extracellular fluid (ECF; via microdialysis, every 15 min) pharmacokinetic (PK) samples were taken during one dosing interval. Phenoxymethylpenicillin concentration data obtained from the microneedles were calibrated using locally estimated scatter plot smoothing and compared with free-blood and microdialysis (gold standard) data. Phenoxymethylpenicillin PK for each method was evaluated using non-compartmental analysis. Area under the concentration-time curve (AUC), maximum concentration, and time to maximum concentration were compared. Bias and limits of agreement were investigated with Bland-Altman plots. Microneedle biosensor limits of detection were estimated. The study was registered with ClinicalTrials.gov, number NCT03847610. Ten healthy volunteers participated in the study. Mean age was 42 years (SD 14). Seven (70%) were men. Microdialysis and microneedle results were similar for phenoxymethylpenicillin ECF maximum concentration (0·74 mg/L vs 0·64 mg/L; 95% CI -0·24 to 0·44; p=0·53), time to maximum concentration (1·18 h vs 1·10 h; -0·52 to 0·67; p=0·79), and AUC (1·54 mg × h/L vs 1·67 mg × h/L; -1·10 to 0·85; p=0·79). In total, 440 time points were compared with mean difference between measurements -0·16 mg/L (95% CI -1·30 to 0·82). Mean phenoxymethylpenicillin AUCs for free serum and microneedle PK were similar (1·77 mg × h/L [SD 0·59] vs 1·67 mg × h/L [1·00]; -0·77 to 0·97; p=0·81). Median coefficient of variation between sensors within individuals was 7% (IQR 4-17). Limit of detection for the microneedles was estimated at 0·17 mg/L. This study is proof-of-concept of real-time, microneedle sensing of penicillin in vivo. Future work will explore microneedle use in patient populations, their role in data generation to inform dosing recommendations, and their incorporation into closed-loop control systems for automated drug delivery. National Institute for Health Research Imperial Biomedical Research Centre, Mérieux Foundation.

10 January 2019 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Paolo BollellaPaolo Bollella
Paolo Bollella
SSSanjiv Sharma
Sanjiv Sharma
ACAnthony Edward George Cass
Anthony Edward George Cass
RARiccarda Antiochia
Riccarda Antiochia

15 October 2016 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
SSSanjiv Sharma
Sanjiv Sharma
ZHZhenyi Huang
Zhenyi Huang
MRMichelle Rogers
Michelle Rogers
MBMartyn Boutelle
Martyn Boutelle
ACAnthony E. G. Cass
Anthony E. G. Cass
We describe here a minimally invasive glucose biosensor based on a microneedle array electrode fabricated from an epoxy-based negative photoresist (SU8 50) and designed for continuous measurement in the dermal compartment with minimal pain. These minimally invasive, continuous monitoring sensor devices (MICoMS) were produced by casting the structures in SU8 50, crosslinking and then metallising them with platinum or silver to obtain the working and reference electrodes, respectively. The metallised microneedle array electrodes were subsequently functionalised by entrapping glucose oxidase in electropolymerised polyphenol (PP) film. Sensor performance in vitro showed that glucose concentrations down to 0.5 mM could be measured with a response times (T90) of 15 s. The effect of sterilisation by Co60 irradiation was evaluated. In preparation for further clinical studies, these sensors were tested in vivo in a healthy volunteer for a period of 3–6 h. The sensor currents were compared against point measurements obtained with a commercial capillary blood glucometer. The epoxy MICoMS devices showed currents values that could be correlated with these. Microneedle arrays for continuous glucose monitoring in dermal interstitial fluid

30 June 2019 in Catalysts
Verified
Journal Article
Open access
PDF file
Paolo BollellaPaolo Bollella
Paolo Bollella
SSSanjiv Sharma
Sanjiv Sharma
ACAnthony E. G. Cass
Anthony E. G. Cass
Federico TascaFederico Tasca
Federico Tasca
RARiccarda Antiochia
Riccarda Antiochia
In this paper, we present the first highly porous gold (h-PG) microneedles-based second-generation biosensor for minimally invasive monitoring of glucose in artificial interstitial fluid (ISF). A highly porous microneedles-based electrode was prepared by a simple electrochemical self-templating method that involves two steps, gold electrodeposition and hydrogen bubbling at the electrode, which were realized by applying a potential of −2 V versus a saturated calomel electrode (SCE). The highly porous gold surface of the microneedles was modified by immobilization of 6-(ferrocenyl)hexanethiol (FcSH) as a redox mediator and subsequently by immobilization of a flavin adenine dinucleotide glucose dehydrogenase (FAD-GDH) enzyme using a drop-casting method. The microneedles-based FcSH/FAD-GDH biosensor allows for the detection of glucose in artificial interstitial fluid with an extended linear range (0.1–10 mM), high sensitivity (50.86 µA cm−2 mM−1), stability (20% signal loss after 30 days), selectivity (only ascorbic acid showed a response about 10% of glucose signal), and a short response time (3 s). These properties were favourably compared to other microneedles-based glucose biosensors reported in the literature. Finally, the microneedle-arrays-based second-generation biosensor for glucose detection was tested in artificial interstitial fluid opportunely spiked with different concentrations of glucose (simulating healthy physiological conditions while fasting and after lunch) and by placing the electrode into a simulated chitosan/agarose hydrogel skin model embedded in the artificial ISF (continuous glucose monitoring). The obtained current signals had a lag-time of about 2 min compared to the experiments in solution, but they fit perfectly into the linearity range of the biosensor (0.1–10 mM). These promising results show that the proposed h-PG microneedles-based sensor could be used as a wearable, disposable, user-friendly, and automated diagnostic tool for diabetes patients.