Optical coherence tomography (OCT) acquires cross-sectional images of tissue by measuring back-reflected light. Images from in vivo OCT systems typically have a resolution of 10 to 15 mm, and are thus best suited for visualizing structures in the range of tens to hundreds of microns, such as tissue layers or glands. Many normal and abnormal tissues lack visible structures in this size range, so it may appear that OCT is unsuitable for identification of these tissues. However, examination of structure-poor OCT images reveals that they frequently display a characteristic texture that is due to speckle. We evaluated the application of statistical and spectral texture analysis techniques for differentiating tissue types based on the structural and speckle content in OCT images. Excellent correct classification rates were obtained when images had slight visual differences (mouse skin and fat, correct classification rates of 98.5 and 97.3%, respectively), and reasonable rates were obtained with nearly identical-appearing images (normal versus abnormal mouse lung, correct classification rates of 64.0 and 88.6%, respectively). This study shows that texture analysis of OCT images may be capable of differentiating tissue types without reliance on visible structures.
Nanoshell-enhanced optical coherence tomography (OCT) is a novel technique with the potential for molecular imaging and improved disease detection. However, optimization of this approach will require a quantitative understanding of the influence of nanoshell parameters on detected OCT signals. In this study, OCT was performed at in water and turbid tissue-simulating phantoms to which nanoshells were added. The effect of nanoshell concentration, core diameter, and shell thickness on signal enhancement was characterized. Experimental results indicated trends that were consistent with predicted optical properties—a monotonic increase in signal intensity and attenuation with increasing shell and core size. Threshold concentrations for a 2-dB OCT signal intensity gain were determined for several nanoshell geometries. For the most highly backscattering nanoshells tested—291-nm core diameter, 25-nm shell thickness—a concentration of nanoshells/mL was needed to produce this signal increase. Based on these results, we discuss various practical considerations for optimizing nanoshell-enhanced OCT. Quantitative experimental data presented here will facilitate optimization of OCT-based diagnostics and may also be relevant to other reflectance-based approaches as well.
We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides ∼18-μm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo.