Jennifer Kehlet Barton

Jennifer Kehlet Barton

Auto-generated profile, based on publicly available information

Jennifer Kehlet Barton

The University of Arizona

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2003 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
KGKirk W. Gossage
Kirk W. Gossage
TTTomasz S. Tkaczyk
Tomasz S. Tkaczyk
JRJeffrey J. Rodriguez
Jeffrey J. Rodriguez
JBJennifer Kehlet Barton
Jennifer Kehlet Barton
Optical coherence tomography (OCT) acquires cross-sectional images of tissue by measuring back-reflected light. Images from in vivo OCT systems typically have a resolution of 10 to 15 mm, and are thus best suited for visualizing structures in the range of tens to hundreds of microns, such as tissue layers or glands. Many normal and abnormal tissues lack visible structures in this size range, so it may appear that OCT is unsuitable for identification of these tissues. However, examination of structure-poor OCT images reveals that they frequently display a characteristic texture that is due to speckle. We evaluated the application of statistical and spectral texture analysis techniques for differentiating tissue types based on the structural and speckle content in OCT images. Excellent correct classification rates were obtained when images had slight visual differences (mouse skin and fat, correct classification rates of 98.5 and 97.3%, respectively), and reasonable rates were obtained with nearly identical-appearing images (normal versus abnormal mouse lung, correct classification rates of 64.0 and 88.6%, respectively). This study shows that texture analysis of OCT images may be capable of differentiating tissue types without reliance on visible structures.

25 October 2007 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
VKVrushali R. Korde
Vrushali R. Korde
GBGarret T. Bonnema
Garret T. Bonnema
WXWei Xu
Wei Xu
CKChetankumar Krishnamurthy
Chetankumar Krishnamurthy
JRJames Ranger‐Moore
James Ranger‐Moore
JBJennifer K. Barton
Jennifer K. Barton

1 January 2006 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
AAAnant Agrawal
Anant Agrawal
SHStanley Huang
Stanley Huang
ALAlex Wei Haw Lin
Alex Wei Haw Lin
MLMin-Ho Lee
Min-Ho Lee
JBJennifer K. Barton
Jennifer K. Barton
JPJoshua Pfefer
Joshua Pfefer
Nanoshell-enhanced optical coherence tomography (OCT) is a novel technique with the potential for molecular imaging and improved disease detection. However, optimization of this approach will require a quantitative understanding of the influence of nanoshell parameters on detected OCT signals. In this study, OCT was performed at 1310nm in water and turbid tissue-simulating phantoms to which nanoshells were added. The effect of nanoshell concentration, core diameter, and shell thickness on signal enhancement was characterized. Experimental results indicated trends that were consistent with predicted optical properties—a monotonic increase in signal intensity and attenuation with increasing shell and core size. Threshold concentrations for a 2-dB OCT signal intensity gain were determined for several nanoshell geometries. For the most highly backscattering nanoshells tested—291-nm core diameter, 25-nm shell thickness—a concentration of 109 nanoshells/mL was needed to produce this signal increase. Based on these results, we discuss various practical considerations for optimizing nanoshell-enhanced OCT. Quantitative experimental data presented here will facilitate optimization of OCT-based diagnostics and may also be relevant to other reflectance-based approaches as well.

1 January 2004 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ATAlexandre R. Tumlinson
Alexandre R. Tumlinson
LHLida P. Hariri
Lida P. Hariri
UUUrs Utzinger
Urs Utzinger
JBJennifer K. Barton
Jennifer K. Barton
We have designed a multimodality system that combines optical coherence tomography (OCT) and laser-induced fluorescence (LIF) in a 2.0-mm-diameter endoscopic package. OCT provides ∼18-μm resolution cross-sectional structural information over a 6-mm field. LIF spectra are collected sequentially at submillimeter resolution across the same field and provide histochemical information about the tissue. We present the use of a rod prism to reduce the asymmetry in the OCT beam caused by a cylindrical window. The endoscope has been applied to investigate mouse colon cancer in vivo.

9 February 2005 in Lasers in Surgery and Medicine
Verified
Journal Article
Closed access
PDF file
JBJohn F. Black
John F. Black
NWNorman Wade
Norman Wade
JBJennifer Kehlet Barton
Jennifer Kehlet Barton

1 August 2009 in Gynecologic Oncology
Verified
Journal Article
Closed access
LHLida P. Hariri
Lida P. Hariri
GBGarret T. Bonnema
Garret T. Bonnema
KSKathy Schmidt
Kathy Schmidt
AWAmy M. Winkler
Amy M. Winkler
VKVrushali Korde
Vrushali Korde
JBJennifer K. Barton
Jennifer K. Barton