Manuel Alberto Susunaga-Miranda

Dr. Manuel Alberto Susunaga-Miranda


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2023 in Enfoque UTE
Verified
Journal Article
Open access
PDF file
MSManuel Alberto Susunaga-Miranda
Manuel Alberto Susunaga-Miranda
Benigno Ortiz-MuñizBenigno Ortiz-Muñiz
Benigno Ortiz-Muñiz
BEBertha María Estévez-Garrido
Bertha María Estévez-Garrido
RSRodrigo Manuel Susunaga-Estévez
Rodrigo Manuel Susunaga-Estévez
MGMario Diaz González
Mario Diaz González
OCOlaya Pirene Castellanos-Onorio
Olaya Pirene Castellanos-Onorio
The Abandoned Sanitary Landfill of the City of Veracruz, located to the north of the municipality, was built in the year 2000 and operated according to the regulations in force at the time, for a useful life of 10 years. However, it continued its operation irregularly, collapsing and becoming a controlled final disposal site that was closed by the state environmental authorities in 2019. Through the use of Google Earth satellite images using multicriteria techniques, it was determined that it has an area of 167 228 m² and an accumulated volume of waste of 1 505 052 m³. The Mexican Biogas Model 2.0 was used to estimate the generation of biogas that until the year 2023 was a total of 2 898 064 tons of biogas, and with the help of the methodology for the greenhouse effect calculation for urban solid waste, it was determined that in this same period a total of 2 522 057.3 tons of carbon dioxide, 1 162 154.8 tons of methane, and 47 115.9 tons of nitrous oxide were emitted. This represents a total of 47.5 Mt CO2 eq., which underscores the importance of minimizing greenhouse gas emissions and their impact on the environment due to global warming of the atmosphere, especially in the coastal ecosystem where the municipality of Veracruz, Mexico is located.

1 July 2021 in Enfoque UTE
Verified
Journal Article
Open access
PDF file
MSManuel Alberto Susunaga-Miranda
Manuel Alberto Susunaga-Miranda
BGBertha Maria Estévez Garrido
Bertha Maria Estévez Garrido
Benigno Ortiz-MuñizBenigno Ortiz-Muñiz
Benigno Ortiz-Muñiz
RERodrigo Manuel Susunaga Estévez
Rodrigo Manuel Susunaga Estévez
El uso de las Barreras reactivas permeables como material para la remoción de metales pesados de los lixiviados de los rellenos sanitarios ha sido comprobado para diversos materiales, la Arena sílica procedente de las costas del municipio de Alvarado Veracruz en México tienen las características de tamaño y composición requeridas para ser utilizadas para este fin, se colectaron muestras de Lixiviado procedente del Relleno Sanitario de la ciudad de Veracruz y se determinaron las concentraciones de Ni, Cr+6 y Zn fueron respectivamente 0.0818, 0.186 y 0.224 mg/l, se construyeron tres columnas de acrílico y se rellenaron con 20, 30 y 40 cm de Arena sílica lavada y seca, se hizo pasar lixiviado tratado y estabilizado por el medio poroso a una a un flujo de 1.7 ml/s, tomando muestras a los 40,75, 115, 165 y 235 segundos para cada columna y se midió la eficacia para la remoción estos metales pesados y se encontró una reducción significativa de estos contaminantes que va desde el de 76 a 93 % para el Níquel, de 44 al 81 % en el caso del Cromo hexavalente y desde 65 hasta el 92 % para el Zinc para un tiempo máximo de 235 segundos, lo que indica que este material puede ser utilizado en la remediación de lixiviados.

1 October 2020 in Enfoque UTE
Verified
Journal Article
Open access
PDF file
MSManuel Alberto Susunaga-Miranda
Manuel Alberto Susunaga-Miranda
BEBertha María Estévez-Garrido
Bertha María Estévez-Garrido
RSRodrigo Manuel Susunaga-Estévez
Rodrigo Manuel Susunaga-Estévez
This article characterizes the silica sand from the coasts of the municipality of Alvarado, Veracruz, Mexico and compares its properties with the materials used for the Permeable Reactive Barriers and that allow its use as a solution for the remediation of aquifers contaminated with leachate from uncontrolled landfills, by granulometric analysis, determination of humidity and concentration of Silica and Iron, obtaining particles with a diameter of 0.707 mm, relative humidity of 0.52% and concentration of SiO2 and Fe2O3 87.38% and 2.72% respectively, which comparing with reactive materials in use meets the criteria to be used as a Barrier for the Remediation of Aquifers contaminated with leachates.

1 April 2024 in Enfoque UTE
Verified
Journal Article
Open access
PDF file
XHXÓCHITL CITLALLI HERNÁNDEZ-SILVA
XÓCHITL CITLALLI HERNÁNDEZ-SILVA
MCMARÍA DEL REFUGIO CASTAÑEDA-CHÁVEZ
MARÍA DEL REFUGIO CASTAÑEDA-CHÁVEZ
MGMario Diaz González
Mario Diaz González
AMANGEL MORAN-SILVA
ANGEL MORAN-SILVA
Fabiola Lango-ReynosoFabiola Lango-Reynoso
Fabiola Lango-Reynoso
MSManuel Alberto Susunaga-Miranda
Manuel Alberto Susunaga-Miranda
The Port of Veracruz, Mexico was artificially built at the beginning of the 21st century, dredging the sea floor and removing reefs to allow the entry of large ships, which led to a growth in the traffic of goods and people through it, making it the largest commercial port in all of Mexico. In 1992 the Government of Mexico decreed the area of coastal reefs near the Port of Veracruz as a protected natural area with the name of the Parque Nacional Sistema Arrecifal Veracruzano (PSNSAV). In 2013, with the demand of international trade, the decision was made to expand the port, generating job growth in the area and an increase in the flow of containers and automobiles, also have a greater capacity to transport cereals, minerals and fuels. In contrast to the disagreements of the society due to the loss of protected space, the Parks polygon had to be modified. This work try to demonstrated that the construction of the port expansion began previous the presentation to the environmental authorities of the Environmental Impact Statement and the change in the protected limits with the disappearance of the Punta Gorda reefs and the dredging of Vergara Bay for the arrival of deep draft vessels. Through a systematic mapping of the scientific literature combined with satellite mapping and visual interpretation of images, and documentary analysis, we determined the damage to the reef system, which has protected species according to Mexican national regulations. El Puerto de Veracruz, México fue construido de manera artificial a principios del siglo XXI, dragando el suelo marino y removiendo arrecifes para permitir la entrada de buques de gran tamaño, lo que conllevó a un crecimiento en el tráfico de mercancías y personas a través de él y convirtiéndolo en el mayor puerto comercial de todo México. En 1992 el Gobierno de México decretó en la zona de arrecifes litorales cercanos al Puerto de Veracruz como un área natural protegida con el nombre de Parque Nacional Sistema Arrecifal Veracruzano (PSNSAV). En 2013, con la demanda del comercio internacional, se tomó la decisión de ampliar el puerto, generando un incremento de empleo en la zona y un aumento del flujo de contenedores y automóviles, además de tener una mayor capacidad para transportar cereales, minerales y combustibles. Frente a las disconformidades de la sociedad por la pérdida de espacio protegido, el polígono de Parques tuvo que ser modificado. Con este trabajo se demuestra que la construcción de la ampliación del puerto se inició previa autorización de las autoridades ambientales de la Manifestación de Impacto Ambiental y el cambio en los límites protegidos, lo dicho tuvo inicio con la desaparición de los arrecifes de Punta Gorda y el dragado de la Bahía de Vergara para el arribo de buques de gran calado. A través de un mapeo sistemático de la literatura científica combinado con mapeo satelital e interpretación visual de imágenes, así como el análisis documental, se determinó el daño al sistema de arrecife, el cual cuenta con especies protegidas de acuerdo a la normatividad nacional mexicana.

1 October 2022 in Enfoque UTE
Verified
Journal Article
Open access
MSManuel Alberto Susunaga-Miranda
Manuel Alberto Susunaga-Miranda
Benigno Ortiz-MuñizBenigno Ortiz-Muñiz
Benigno Ortiz-Muñiz
MCMARÍA DEL REFUGIO CASTAÑEDA-CHÁVEZ
MARÍA DEL REFUGIO CASTAÑEDA-CHÁVEZ
Fabiola Lango-ReynosoFabiola Lango-Reynoso
Fabiola Lango-Reynoso
Maria del Consuelo Hernandez-BerrielMaria del Consuelo Hernandez-Berriel
Maria del Consuelo Hernandez-Berriel
In Mexico, when municipal solid waste final disposal sites are closed or complete their life cycle, municipal authorities abandon them without carrying out remediation processes. In the Sotavento Region, state of Veracruz, Mexico, through geographic information systems, interviews with municipalities and field visits, 9 abandoned dumpsites were located: two sanitary landfills, two controlled final disposal sites called controlled dumps, and five uncontrolled final disposal sites known as open-air dumps. The results using Google Earth made it possible to determine that these dumps, as a whole, occupied an area of 366,852 m2, with an accumulated volume of waste of 2,015,500m3 and an estimated quantity of 2,498,571 tons of confined waste without control. Such results represent a series of environmental impacts that are commonly not detected and whose knowledge can be the starting point for its closure in accordance with the applicable Mexican regulations.

13 November 2026 in Revista Facultad de Ingeniería Universidad de Antioquia
Verified
Journal Article
Open access
PDF file
AAAlan Enrique Angulo-Valenzuela
Alan Enrique Angulo-Valenzuela
DPDavid Emilio Perdomo-Montes
David Emilio Perdomo-Montes
MSManuel Alberto Susunaga-Miranda
Manuel Alberto Susunaga-Miranda
JLJosé Satsumi López-Morales
José Satsumi López-Morales
RRRodolfo Alberto Román-Montano
Rodolfo Alberto Román-Montano
This article presents the development of an energy baseline for an agrivoltaicsystem located in the Yaqui Valley, Sonora, Mexico, in accordance with ISO 50001:2018.The baseline was established by quantifying electricity and fuel consumption (gasolineand diesel) associated with agricultural activities, including irrigation, planting, andharvesting. Energy data were analyzed by two-month periods, and a linear regressionmodel was applied to the months with the highest activity, excluding low-consumptionperiods to avoid distortion. The consumption analysis was performed by dividing thetotal energy consumption during the corresponding period by the number of hectaresharvested. The results revealed that fuel use accounts for a significant share oftotal energy consumption, underscoring the need to evaluate all energy sources.The resulting baseline model enables disaggregation of fixed and variable loads andserves as a valuable tool for performance monitoring, energy audits, and continuousimprovement strategies. This baseline can be used as a reference for future energymanagement initiatives in similar agricultural settings.