Background: The aim of this systematic review was to evaluate the survival rates of immediately loaded implants after at least five years. Besides implant failure, the amount of marginal bone loss around implants and the complication type were assessed. Methods: The electronic search was undertaken on Medline, Scopus, and Cochrane Central Register of Controlled Trials using key terms such as: “immediate loading”, “immediate function”, “immediate restoration”, “immediate temporization”, “dental implants”, “fully edentulous patients”, “partially edentulous patients”. The search terms were combined using the Boolean operators AND, OR. The last electronic search was performed on 15 February 2018. Two authors independently screened the studies, extracted the data, and assessed the risk-of bias. The main outcomes recorded for each study were: implant and prosthesis success and survival, marginal bone level change, incidence and type of complications. Kaplan–Meier analysis was used to estimate cumulative survival rates. Results: Thirty-four prospective studies with at least five-year follow-up, published between 2007 and 2017 were included. A total of 5349 immediately loaded implants in 1738 patients were analyzed. The mean follow-up was 72.4 months (median 60 months, 95% confidence intervals (CI): 64.53, 80.25 months, range 60 to 147 months). The mean weighted implant survival was 97.4% (median 98.15%, 95% CI: 96.29%, 98.54%, range 83.80% to 100%). Cumulative survival rate of implants placed in the mandible was significantly higher than for the maxilla (p < 0.01). No significant difference in failure rate was found among the types of prosthesis employed (p = 0.27). The mean peri-implant bone level change at the end of the follow-up in each study ranged from 0.3 to 1.7 mm. Conclusion: Immediate loading of implants appears to have long-term predictability and success rate under well-defined circumstances.
Background: The aim of the present review was to assess the histological and histomorphometrical data from the paper published by our Laboratory on peri-implant bone in dental implants in different loading conditions. Methods: The papers published in different implant loading conditions, in dental implants retrieved from humans, and in the Hard Tissues Research Center of the University of Chieti-Pescara, Italy, were screened on MEDLINE/PubMed, Embase, Scopus, and other electronic databases until 31 December 2018. Only articles that reported the histological and histomorphometrical values of the Bone-Implant Contact (BIC) were selected. Results: The system selection provided a total of 155 papers. The manuscripts included for the narrative review were 57. These papers provided histological and histomorphometrical data. Conclusions: The bone remodeling around dental implants was found to be a dynamic process; loading changed the microstructure of the peri-implant bone; and implants were found to provide a successful function, over several decades, with different range of degrees of BIC in vivo (varying from a little more than 30% to a little more than 90%). Loaded implants presented a 10%–12% higher BIC values when compared to submerged, unloaded implants, and rougher surfaces had, on average, about a 10% higher BIC than machined surfaces.
This systematic review is aimed at evaluating the effectiveness of synthetic block materials for bone augmentation in preclinical in vivo studies. An electronic search was performed on Pubmed, Scopus, EMBASE. Articles selected underwent risk-of-bias assessment. The outcomes were: new bone formation and residual graft with histomorphometry, radiographic bone density, soft tissue parameters, complications. Meta-analysis was performed to compare new bone formation in test (synthetic blocks) vs. control group (autogenous blocks or spontaneous healing). The search yielded 214 articles. After screening, 39 studies were included, all performed on animal models: rabbits (n = 18 studies), dogs (n = 4), rats (n = 7), minipigs (n = 4), goats (n = 4), and sheep (n = 2). The meta-analysis on rabbit studies showed significantly higher new bone formation for synthetic blocks with respect to autogenous blocks both at four-week (mean difference (MD): 5.91%, 95% confidence intervals (CI): 1.04, 10.79%, p = 0.02) and at eight-week healing (MD: 4.44%, 95% CI: 0.71, 8.17%, p = 0.02). Other animal models evidenced a trend for better outcomes with synthetic blocks, though only based on qualitative analysis. Synthetic blocks may represent a viable resource in bone regenerative surgery for achieving new bone formation. Differences in the animal models, the design of included studies, and the bone defects treated should be considered when generalizing the results. Clinical studies are needed to confirm the effectiveness of synthetic blocks in bone augmentation procedures.
Over the years, several bone regeneration procedures have been proposed using natural (autografts, allografts, and xenografts) and synthetic (i.e., metals, ceramics, and polymers) bone grafts. In particular, numerous in vitro and human and animal in vivo studies have been focused on the discovery of innovative and suitable biomaterials for oral and maxillofacial applications in the treatment of severely atrophied jaws. On this basis, the main objective of the present narrative review was to investigate the efficacy of innovative collagenated porcine bone grafts (OsteoBiol®, Tecnoss®, Giaveno, Italy), designed to be as similar as possible to the autologous bone, in several bone regeneration procedures. The scientific publications were screened by means of electronic databases, such as PubMed, Scopus, and Embase, finally selecting only papers that dealt with bone substitutes and scaffolds for bone and soft tissue regeneration. A total of 201 papers have been detected, including in vitro, in vivo, and clinical studies. The effectiveness of over 20 years of translational research demonstrated that these specific porcine bone substitutes are safe and able to improve the biological response and the predictability of the regenerative protocols for the treatment of alveolar and maxillofacial defects.
Background: The aim of the present study was to compare, in low-density polyurethane blocks, the primary implant stability values (micromobility) and removal torque values of three different implant geometries in two different bone densities representing the structure of the human posterior jaws. Methods: A total of 60 implants were used in the present investigation: twenty implants for each of three groups (group A, group B, and group C), in both polyurethane 10 pcf and 20 pcf densities. The insertion torque, pull-out torque, and implant stability quotient (ISQ) values were obtained. Results: No differences were found in the values of Group A and Group B implants. In both these groups, the insertion torques were quite low in the 10 pcf blocks. Better results were found in the 20 pcf blocks, which showed very good stability of the implants. The pull-out values were slightly lower than the insertion torque values. High ISQ values were found in Group A and B implants. Lower values were present in Group C implants. Conclusions: The present investigation evaluated implants with different geometries that are available on the market, and not experimental implants specifically created for the study. The authors aimed to simulate real clinical conditions (poor-density bone or immediate post-extraction implants) in which knowledge of dental implant features, which may be useful in increasing the primary stability, may help the oral surgeon during the surgery planning.
25 August 2020 in Computer Methods in Biomechanics and Biomedical Engineering
The implant primary stability is a fundamental condition for avoiding implant micro-motions that might result in fibrous encapsulation; its achievement is facilitated by macro- and micro-geometry of the implant, and by the bone density and architecture at the intended implant site. The aim was to evaluate an osteocondensing drilling protocol for dental implant positioning compared to standard protocol on polyurethane block. A total of 40 implants, 20 for each osteocondensing group (Test) and 20 for standard drilling group (Control), were positioned. Insertion torque (IT), removal torque (RT), and Periotest were measured. A IT, RT, and Periotest significant difference was present in favor of the implant osteocondensing protocol. The results suggested that osteocondensing protocol represents a useful technique for implant placement in poor density bone.