Evgenii Kim

Mr. Evgenii Kim


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2019 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
EKEvgenii Kim
Evgenii Kim
EAEloise Anguluan
Eloise Anguluan
SYSangyeon Youn
Sangyeon Youn
JKJihun Kim
Jihun Kim
JHJae Youn Hwang
Jae Youn Hwang
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
Transcranial focused ultrasound (tFUS) attracts wide attention in neuroscience as an effective noninvasive approach to modulate brain circuits. In spite of this, the effects of tFUS on the brain is still unclear, and further investigation is needed. The present study proposes to use near-infrared spectroscopy (NIRS) to observe cerebral hemodynamic change caused by tFUS in a noninvasive manner. The results show a transient increase of oxyhemoglobin and decrease of deoxyhemoglobin concentration in the mouse model induced by ultrasound stimulation of the somatosensory cortex with a frequency of 8 MHz but not in sham. In addition, the amplitude of hemodynamics change can be related to the peak intensity of the acoustic wave. High frequency 8 MHz ultrasound was shown to induce hemodynamic changes measured using NIRS through the intact mouse head. The implementation of NIRS offers the possibility of investigating brain response noninvasively for different tFUS parameters through cerebral hemodynamic change.

21 February 2015 in BMC Urology
Verified
Journal Article
Open access
PDF file
EKEvgenii Kim
Evgenii Kim
SLSonghyun Lee
Songhyun Lee
ZVZephaniah Phillips V
Zephaniah Phillips V
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
In this paper, we observed a discrepancy of penile hemodynamics dependent on location by using near infrared spectroscopy (NIRS) sensor, and showcase NIRS as a potentially suitable sensor in supplementing the diagnosis and treatment of erectile dysfunction. To observe the effect that location has on penile hemodynamics, the NIRS sensor was placed on the top and the side of genital organ, and oxy- (HbO), deoxy-(RHb), and total (HbT) hemoglobin concentration changes were acquired. Our results from 6 healthy subjects show that hemodynamic changes vary depending on where the probe was placed. To observe a statistical difference between the signals, a Wilcoxon signed-rank test was performed. The result shows a significant difference (p < 0.05) between concentration changes of RHb and HbT depending on the probes’ location. Moreover, the sensor placed on the top of the organ shows a rise of HbO and HbT concentration while RHb concentration decreased. However, hemodynamics from the side of the organ showed that RHb concentration increased along with HbO. The outcomes demonstrates an ability of NIRS to be sensitive enough to detect the different hemodynamic changes in various locations of a healthy male genital organ during visual sexual stimulation. The results also show the importance of sensor location on the genital organ for the resulting hemodynamic changes. We can foresee our results as a way for clinicians to obtain more accurate hemodynamic measurements from the penis, and also show the likelihood for NIRS enhanced diagnosis tool of male erectile dysfunction over the current standards.