Sangyeon Youn

Dr. Sangyeon Youn

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MLMOONHWAN LEE
MOONHWAN LEE
HLHah Min Lew
Hah Min Lew
SYSangyeon Youn
Sangyeon Youn
TKTae Kim
Tae Kim
JHJae Youn Hwang
Jae Youn Hwang
Acoustic holography has been gaining attention for various applications such as non-contact particle manipulation, non-invasive neuromodulation, and medical imaging. However, only a few studies on how to generate acoustic holograms have been conducted, and even conventional acoustic hologram algorithms show limited performance in the fast and accurate generation of acoustic holograms, thus hindering the development of novel applications. We here propose a deep learning-based framework to achieve fast and accurate acoustic hologram generation. The framework has an autoencoder-like architecture; thus the unsupervised training is realized without any ground truth. For the framework, we demonstrate a newly developed hologram generator network, the Holographic Ultrasound generation Network (HU-Net), which is suitable for unsupervised learning of hologram generation, and a novel loss function that is devised for energy-efficient holograms. Furthermore, for considering various hologram devices (i.e., ultrasound transducers), we propose a physical constraint layer. Simulation and experimental studies were carried out for two different hologram devices such as a 3D printed lens, attached to a single element transducer, and a 2D ultrasound array. The proposed framework was compared with the iterative angular spectrum approach (IASA) and the state-of-the-art iterative optimization method, Diff-PAT. In the simulation study, our framework showed a few hundred times faster generation speed, along with comparable or even better reconstruction quality, than those of IASA and Diff-PAT. In the experimental study, the framework was validated with 3D-printed lenses fabricated based on different methods, and the physical effect of the lenses on the reconstruction quality was discussed. The outcomes of the proposed framework in various cases (i.e., hologram generator networks, loss functions, hologram devices) suggest that our framework may become a very useful alternative tool for other existing acoustic hologram applications and it can expand novel medical applications.

5 September 2022 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
HKHaemin Kim
Haemin Kim
SYSangyeon Youn
Sangyeon Youn
JKjinwoo kim
jinwoo kim
SPSunghun Park
Sunghun Park
MLMOONHWAN LEE
MOONHWAN LEE
Jin Ho ChangJin Ho Chang
Jin Ho Chang

18 March 2019 in BMC Neuroscience
Verified
Journal Article
Open access
PDF file
EKEvgenii Kim
Evgenii Kim
EAEloise Anguluan
Eloise Anguluan
SYSangyeon Youn
Sangyeon Youn
JKJihun Kim
Jihun Kim
JHJae Youn Hwang
Jae Youn Hwang
Jae Gwan KimJae Gwan Kim
Jae Gwan Kim
Transcranial focused ultrasound (tFUS) attracts wide attention in neuroscience as an effective noninvasive approach to modulate brain circuits. In spite of this, the effects of tFUS on the brain is still unclear, and further investigation is needed. The present study proposes to use near-infrared spectroscopy (NIRS) to observe cerebral hemodynamic change caused by tFUS in a noninvasive manner. The results show a transient increase of oxyhemoglobin and decrease of deoxyhemoglobin concentration in the mouse model induced by ultrasound stimulation of the somatosensory cortex with a frequency of 8 MHz but not in sham. In addition, the amplitude of hemodynamics change can be related to the peak intensity of the acoustic wave. High frequency 8 MHz ultrasound was shown to induce hemodynamic changes measured using NIRS through the intact mouse head. The implementation of NIRS offers the possibility of investigating brain response noninvasively for different tFUS parameters through cerebral hemodynamic change.

25 July 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HLHaeyun Lee
Haeyun Lee
MLMOONHWAN LEE
MOONHWAN LEE
SYSangyeon Youn
Sangyeon Youn
KLKyungsu Lee
Kyungsu Lee
HLHah Min Lew
Hah Min Lew
JHJae Youn Hwang
Jae Youn Hwang
The performance of computer-aided diagnosis (CAD) systems that are based on ultrasound imaging has been enhanced owing to the advancement in deep learning. However, because of the inherent speckle noise in ultrasound images, the ambiguous boundaries of lesions deteriorate and are difficult to distinguish, resulting in the performance degradation of CAD. Although several methods have been proposed to reduce speckle noise over decades, this task remains a challenge that must be improved to enhance the performance of CAD. In this article, we propose a deep content-aware image prior (DCAIP) with a content-aware attention module (CAAM) for superior despeckling of ultrasound images without clean images. For the image prior, we developed a CAAM to deal with the content information in an input image. In this module, super-pixel pooling (SPP) is used to give attention to salient regions in an ultrasound image. Therefore, it can provide more content information regarding the input image when compared to other attention modules. The DCAIP consists of deep learning networks based on this attention module. The DCAIP is validated by applying it as a preprocessing step for breast tumor segmentation in ultrasound images, which is one of the tasks in CAD. Our method improved the segmentation performance by 15.89% in terms of the area under the precision–recall (PR) curve (AUPRC). The results demonstrate that our method enhances the quality of ultrasound images by effectively reducing speckle noise while preserving important information in the image, promising for the design of superior CAD systems.

25 November 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
JCJae Suk Choi
Jae Suk Choi
SYSangyeon Youn
Sangyeon Youn
JHJae Youn Hwang
Jae Youn Hwang
Sohmyung HaSohmyung Ha
Sohmyung Ha
CKChul Kim
Chul Kim
MJMinkyu Je
Minkyu Je
This brief reviews high-voltage pulsers for ultrasound imaging systems with a focus on energy efficiency. Most ultrasound imaging systems have been developed with the aim of achieving a high signal-to-noise ratio for good image quality. As miniaturization and portability of the systems are pursued recently, high energy efficiency is of great need. In the ultrasonic imaging systems, the most power-hungry block is typically the pulser that drives the ultrasound transducer at a high voltage. To better understand the pulser’s operation and power consumption, an equivalent circuit model of the transducer is introduced. Based on the model, we investigate the fundamentals of pulser driving methods and review the conventional class-D pulser as well as state-of-the-art pulsers with dynamic power loss reduction techniques. Their operation principles, strengths, and limitations are analyzed and discussed in depth.

11 May 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
SYSangyeon Youn
Sangyeon Youn
KLKyungsu Lee
Kyungsu Lee
JSJeehoon Son
Jeehoon Son
IYIn-Hwan Yang
In-Hwan Yang
JHJae Youn Hwang
Jae Youn Hwang
A single-beam acoustic trapping technique has been shown to be very useful for determining the invasiveness of suspended breast cancer cells in an acoustic trap with a manual calcium analysis method. However, for the rapid translation of the technology into the clinic, the development of an efficient/accurate analytical method is needed. We, therefore, develop a fully-automatic deep learning-based calcium image analysis algorithm for determining the invasiveness of suspended breast cancer cells using a single-beam acoustic trapping system. The algorithm allows to segment cells, find trapped cells, and quantify their calcium changes over time. For better segmentation of calcium fluorescent cells even with vague boundaries, a novel deep learning architecture with multi-scale/multi-channel convolution operations (MM-Net) is devised and constructed by a target inversion training method. The MM-Net outperforms other deep learning models in the cell segmentation. Also, a detection/quantification algorithm is developed and implemented to automatically determine the invasiveness of a trapped cell. For the evaluation of the algorithm, it is applied to quantify the invasiveness of breast cancer cells. The results show that the algorithm offers similar performance to the manual calcium analysis method for determining the invasiveness of cancer cells, suggesting that it may serve as a novel tool to automatically determine the invasiveness of cancer cells with high-efficiency.