Kwang Suk Park

Kwang Suk Park


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2017 in Sensors
Verified
Journal Article
Open access
PDF file
HJHyoseon Jeon
Hyoseon Jeon
WLWoongwoo Lee
Woongwoo Lee
HPHyeyoung Park
Hyeyoung Park
HLHong Ji Lee
Hong Ji Lee
SKSang Kyong Kim
Sang Kyong Kim
KPKwang Suk Park
Kwang Suk Park
Although there is clinical demand for new technology that can accurately measure Parkinsonian tremors, automatic scoring of Parkinsonian tremors using machine-learning approaches has not yet been employed. This study aims to fill this gap by proposing machine-learning algorithms as a way to predict the Unified Parkinson’s Disease Rating Scale (UPDRS), which are similar to how neurologists rate scores in actual clinical practice. In this study, the tremor signals of 85 patients with Parkinson’s disease (PD) were measured using a wrist-watch-type wearable device consisting of an accelerometer and a gyroscope. The displacement and angle signals were calculated from the measured acceleration and angular velocity, and the acceleration, angular velocity, displacement, and angle signals were used for analysis. Nineteen features were extracted from each signal, and the pairwise correlation strategy was used to reduce the number of feature dimensions. With the selected features, a decision tree (DT), support vector machine (SVM), discriminant analysis (DA), random forest (RF), and k-nearest-neighbor (kNN) algorithm were explored for automatic scoring of the Parkinsonian tremor severity. The performance of the employed classifiers was analyzed using accuracy, recall, and precision, and compared to other findings in similar studies. Finally, the limitations and plans for further study are discussed.

23 March 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SSSoo Young Sim
Soo Young Sim
MKMyung Jun Koh
Myung Jun Koh
KJKwang Min Joo
Kwang Min Joo
SNSeungwoo Noh
Seungwoo Noh
SPSangyun Park
Sangyun Park
KPKwang Suk Park
Kwang Suk Park
Thermal comfort is an essential environmental factor related to quality of life and work effectiveness. We assessed the feasibility of wrist skin temperature monitoring for estimating subjective thermal sensation. We invented a wrist band that simultaneously monitors skin temperatures from the wrist (i.e., the radial artery and ulnar artery regions, and upper wrist) and the fingertip. Skin temperatures from eight healthy subjects were acquired while thermal sensation varied. To develop a thermal sensation estimation model, the mean skin temperature, temperature gradient, time differential of the temperatures, and average power of frequency band were calculated. A thermal sensation estimation model using temperatures of the fingertip and wrist showed the highest accuracy (mean root mean square error [RMSE]: 1.26 ± 0.31). An estimation model based on the three wrist skin temperatures showed a slightly better result to the model that used a single fingertip skin temperature (mean RMSE: 1.39 ± 0.18). When a personalized thermal sensation estimation model based on three wrist skin temperatures was used, the mean RMSE was 1.06 ± 0.29, and the correlation coefficient was 0.89. Thermal sensation estimation technology based on wrist skin temperatures, and combined with wearable devices may facilitate intelligent control of one’s thermal environment.

12 August 2014 in Sensors
Verified
Journal Article
Open access
PDF file
JLJeongsu Lee
Jeongsu Lee
JHJeong Heo
Jeong Heo
WLWon Kyu Lee
Won Kyu Lee
YLYong Gyu Lim
Yong Gyu Lim
YKYoun Ho Kim
Youn Ho Kim
KPKwang Suk Park
Kwang Suk Park
This study proposes the use of flexible capacitive electrodes for reducing motion artifacts in a wearable electrocardiogram (ECG) device. The capacitive electrodes have conductive foam on their surface, a shield, an optimal input bias resistor, and guarding feedback. The electrodes are integrated in a chest belt, and the acquired signals are transmitted wirelessly for ambulatory heart rate monitoring. We experimentally validated the electrode performance with subjects standing and walking on a treadmill at speeds of up to 7 km/h. The results confirmed the highly accurate heart rate detection capacity of the developed system and its feasibility for daily-life ECG monitoring.

1 September 2018 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
SCSang Ho Choi
Sang Ho Choi
HYHeenam Yoon
Heenam Yoon
HKHyun Seok Kim
Hyun Seok Kim
HKHan Byul Kim
Han Byul Kim
HKHyun Bin Kwon
Hyun Bin Kwon
KPKwang Suk Park
Kwang Suk Park

23 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JHJeong Heo
Jeong Heo
HYHeenam Yoon
Heenam Yoon
KPKwang Suk Park
Kwang Suk Park
Amyotrophic lateral sclerosis (ALS) patients whose voluntary muscles are paralyzed commonly communicate with the outside world using eye movement. There have been many efforts to support this method of communication by tracking or detecting eye movement. An electrooculogram (EOG), an electro-physiological signal, is generated by eye movements and can be measured with electrodes placed around the eye. In this study, we proposed a new practical electrode position on the forehead to measure EOG signals, and we developed a wearable forehead EOG measurement system for use in Human Computer/Machine interfaces (HCIs/HMIs). Four electrodes, including the ground electrode, were placed on the forehead. The two channels were arranged vertically and horizontally, sharing a positive electrode. Additionally, a real-time eye movement classification algorithm was developed based on the characteristics of the forehead EOG. Three applications were employed to evaluate the proposed system: a virtual keyboard using a modified Bremen BCI speller and an automatic sequential row-column scanner, and a drivable power wheelchair. The mean typing speeds of the modified Bremen brain–computer interface (BCI) speller and automatic row-column scanner were 10.81 and 7.74 letters per minute, and the mean classification accuracies were 91.25% and 95.12%, respectively. In the power wheelchair demonstration, the user drove the wheelchair through an 8-shape course without collision with obstacles.

1 July 2014 in Clinical Neurophysiology
Verified
Journal Article
Closed access
MCMin Hye Chang
Min Hye Chang
HBHyun Jae Baek
Hyun Jae Baek
SLSeung Min Lee
Seung Min Lee
KPKwang Suk Park
Kwang Suk Park